• 제목/요약/키워드: temperature zone

검색결과 1,877건 처리시간 0.029초

강교용 박스거더의 용접예열 온도 선정에 관한 연구 (Determination of Preheating Temperature for Box Girder Welding)

  • 조재훈;문승재;유호선
    • 플랜트 저널
    • /
    • 제7권1호
    • /
    • pp.49-55
    • /
    • 2011
  • This study analyzed causes and status of cracks to suggest preventives for welding cracks generated on fillet welding zone of atmosphere corrosion resisting steel box girder. Penetrant testing, a sort of non-destructive testing, was conducted for inspection of crack status on welding zone. As a result of test, welding cracks were found on the point of start, center and end to fillet welding zone of 32 mm-thickness. The result of carbon equivalent composition of materials was 0.452%. According to welding specification, to preheat prevent welding crack, preheat temperature of $100{\sim}200^{\circ}C$ should be kept before welding execution. It was failed to keep preheat temperature because it had been executed on winter season and the structure of box girder had wide heat transfer area. As a result of examination of time varying preheating temperature of 32mm-thickness material, it was understood that preheat temperature of above $230^{\circ}C$ on both 130mm-long sides of welded joint can prevent welding crack.

  • PDF

고온 공기분사공정에 의한 유류오염대수층의 TPH 제거 (TPH Removal of Oil-Contaminated Soil by Hot Air Sparging Process)

  • 이준호;박갑성
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.665-675
    • /
    • 2007
  • In-situ Air Sparging (IAS, AS) is a remediation technique in which organic contaminants are volatilized from saturated zone to unsaturated layer. This study focuses on the removal and interaction of Volatile Organic Compounds (VOCs) and $CO_2$, and Total Petroleum Hydrocarbon (TPH) in saturated and unsaturated, and air space zone on the unsaturated soil surface. Soil sparging temperature of hot air has risen to $34.9{\pm}2.7^{\circ}C$ from $23.0{\pm}1.9^{\circ}C$ for 36 days. At the diffusing point, fluid TPH concentrations were reduced to 78.7% of the initial concentration in saturated zone when hot air was sparged. The TPH concentrations were decreased to 66.1% for room temperature air sparging. The amount of VOCs for hot air sparging system, in air space, was approximately 26% larger than constant air sparging system. The amount of $CO_2$ was 4,555 mg (in unsaturated zone) and 4,419 mg (in air space) when hot air was sparged was 3,015 mg (in unsaturated zone) and 3,634 mg (in air space) for room air temperature in the $CO_2$ amount. The removals of VOCs and biodegradable $CO_2$ through the hot air sparging system (modified SVE) were more effective than the room temperature air sparging. The regression equation were $Y=976.4e^{-0.015{\cdot}X}$, $R^2=0.98$ (hot air sparging) and $Y=1055e^{-0.028{\cdot}X}$, $R^2=0.90$ (room temperaure air sparging). Estimated remediation time was approximately 500 days, if final saturated soil TPH concentration was set to 1.2 mg/L application of tail effect.

근권부 국부 냉방이 토마토 묘 생육에 미치는 영향 (Effect of Root-zone Local Cooling on Seedling Growth of Tomato)

  • 김은지;황현승;주세훈;나해영
    • 생물환경조절학회지
    • /
    • 제31권4호
    • /
    • pp.286-291
    • /
    • 2022
  • 본 연구는 근권부 냉방이 토마토 육묘 시 묘 생육에 미치는 영향을 구명하고자 수행되었다. 생장상 하부 파이프 냉방을 이용하여 근권부 온도를 20℃와 25℃로 설정하여 실험을 수행하였다. 전 생육기간동안 초장, 근장, 엽수는 두 온도 처리구간 차이를 보이지 않았다. 엽면적, 지상부와 지하부의 생체중 및 건물중, 엽록소 함량은 파종 28일 경과 시 25℃ 처리구가 더 높았으며, 실험 종료 시 두 처리구 간 유의한 차이를 보이지 않았다. 이상의 결과로 근권부 온도 20℃와 25℃에서 토마토 생육 차이를 확인하지 못했다. 따라서, 본 연구는 고온기 토마토 묘 생산 시 온실 냉방 효율을 높이기 위한 국부 냉방 기술 확립에 도움을 줄 수 있을 것이다.

연소용 공기중 $N_2$$CO_2$대체에 대한 연소특성 해석 (A Study on the Characteristics of Combustion for Substituting $CO_2\;for\;N_2$ in Combustion Air)

  • 김한석;안국영;김호근;이윤원;이창언
    • 한국연소학회지
    • /
    • 제7권4호
    • /
    • pp.29-35
    • /
    • 2002
  • [$CO_2$] is a well-known greenhouse gas, which is the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. The central method of low $CO_2$ emission is Oxygen/CxHy combustion. Theoretically Oxygen/CxHy combustion only produces $CO_2\;and\;H_2O$ and allows convenient recovery of $CO_2$. The combustion characteristics, flame stability, composition in the flame zone and temperature profile were studied experimentally for various compositions of oxidant by substituting $CO_2\;for\;N_2$ with the constant $O_2$ concentration. Results showed that flame became unstable due to the high heat capacity, low transport rate and strong radiation effect of $CO_2$ in comparison with those of $N_2$. The reaction zone was quenched and broadened, as the ratio of $CO_2\;to\;N_2$ was increased. The emission of NOx in flue gas decreased due to the decreased temperature of the reaction zone. As the conversion ratio of $CO_2\;to\;N_2$ was increased, the emission of CO and the higher temperature zone increased due to decrease of reaction rate by the a quenching effect.

  • PDF

CMC 모델 기반 수치해석을 사용한 순산소 난류확산화염 구조 연구 (A Study on the Structure of Turbulent non-Premixed Oxy-fuel Flame Using CMC Model-based Simulation)

  • 김종수;;허강열;양원
    • 한국연소학회지
    • /
    • 제13권1호
    • /
    • pp.31-43
    • /
    • 2008
  • Oxy-fuel flame has a significantly different structure from that of air-fuel flame because of its high temperature. This study is aimed to find out the difference of the oxy-fuel flame structure in order to understand reaction mechanism closely, which is crucial to design real-scale oxy-fuel combustion system. By examining pictures of counterflow flame and LIF images, we found that oxy-fuel flame had two-zone structure: fuel decomposition region and distributed CO oxidation region. In the oxy-fuel flame, OH radical was distributed intensely through the whole flame due to its higher flame temperature than crossover temperature. For showing those features of the oxy-fuel flame, 1 MW scale IFRF oxy-natural gas burner was simulated by conditional moment closure(CMC) model. Calculation results were compared with experimental data, and showed agreements in trend. In the simulated distributions of fuel decomposition/CO oxidation rates, CO oxidation region was also separated from fuel decomposition zone considerably, which showed the two-zone structure in the oxy-fuel flame.

  • PDF

페라이트계 스테인리스강의 재현 용접열영향부 열피로 특성 (Thermal Fatigue Properties of Synthetic Beat Affected Zone in Ferritic Stainless Steel)

  • 홍승갑;조민현;강기봉
    • Journal of Welding and Joining
    • /
    • 제27권1호
    • /
    • pp.79-84
    • /
    • 2009
  • Ferritic stainless steel, which has been used as material for decoration parts in automobile, is recently used as material for the exhaust system due to its good performance at high temperature. To improve the fuel efficiency and purify automotive exhaust gas, it is needed to increase the temperature of exhaust gas. However, it is frequently reported that the rising of the temperature of exhaust gas increases thermal stress at exhaust manifold, which results in thermal fatigue failure in welded joints. Therefore, in this study, effects of chemical composition of steel and welding parameters on thermal fatigue properties of synthetic heat affected zone in ferritic stainless steel have been investigated. It has been found that thermal fatigue life in heat affected zone is affected by bead shape of welded joint and amount of soluble Nb in steel. Especially, Nb-Ti added steel has higher thermal fatigue life in comparison to Nb added steel, which is attributed to difference of precipitation behavior in both steels.

아트리움 공간에 있어서 연기 유동에 관한 수치해석적 연구 (A Numerical Study of Smoke Movement In Atrium Space)

  • 노재성;유홍선;정연태;김충익;윤명오
    • 한국화재소방학회논문지
    • /
    • 제11권4호
    • /
    • pp.3-14
    • /
    • 1997
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire model : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed frie field model based on Computational Fluid Dynamic (CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. For solving the liked set of velocity and pressure equation, the PISO algorithm, which strengthened the velocity-pressure coupling, was used. Since PISO algorithm is a time-marching procedure, computing time si very fast. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i.e Zone model and Field model predicted similar results for clear heights and the smoke layer temperature.

  • PDF

복합열원설비 운전온도 최적 설정에 관한 해석적 연구 (An Analytical Study on the Optimal Set-point of the Hybrid Plant)

  • 전종욱;이선일;이태원;김용기;홍대희;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.352-357
    • /
    • 2007
  • The objective of this study is to find the optimal set-point of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Ground Source Heat Pump) and the conventional plant(chiller, boiler). The work presented in this study was carried out by using the EnergyPlus(Version 2.0). In order to validate the simulation model, field data were measured from a building. The GSHP was used as a base plant and the conventional plant as the assistant plant. Various temperatures were controlled (zone summer set-point, zone winter set-point, chilled water temperature, hot water temperature) to find the optimal set-point temperature of the system. The influence of the various set-points were analyzed seasonally.

  • PDF

재결정에 따른 Alloy 617의 고온 산화 거동 및 기계적 특성 (High Temperature Oxidation Behavior and Mechanical Characteristic of Recrystallized Alloy 617)

  • 임정훈;조태선;박지연;김영도
    • 대한금속재료학회지
    • /
    • 제48권12호
    • /
    • pp.1078-1083
    • /
    • 2010
  • In this study, high temperature oxidation behavior of Alloy 617 was investigated to evaluate the effect of grain size for Alloy 617. The grain size of grain-refined Alloy 617 (GR617) was reduced to $5{\mu}m$ from $71{\mu}m$ for as-received Alloy 617 (AR617) by recrystallization after cold rolling. After high temperature aging, the oxide layers of AR617 and GR617 consisted of $Cr_2O_3$ external oxide scale and $Al_2O_3$ internal oxide. The external oxide scale resulted in a Cr-depleted zone and a carbide free zone below the scale. The depth of the carbide free zone was deeply formed in GR617. On the other hand, the depth of the internal oxide layer in GR617 was shorter than that in AR617. After a 3-point bending test, crack propagation of GR617 was more restricted than that of AR617 because of the different microstructure of the internal oxide.

온수배관을 이용한 시설딸기 부분난방기술 개발 (Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe)

  • 문종필;강금춘;권진경;백이;이태석;오성식;남명현
    • 한국농공학회논문집
    • /
    • 제58권5호
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.