• Title/Summary/Keyword: temperature standards

Search Result 885, Processing Time 0.025 seconds

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

Clinical review of Typhoid Fever Patients (장티브스에 관한 임상적 관찰)

  • 최정신
    • Journal of Korean Academy of Nursing
    • /
    • v.6 no.1
    • /
    • pp.60-71
    • /
    • 1976
  • The author reviewed the medical records of 96 typhoid fever patients who were diagnosed, admitted, and treated at Sea grave Memorial Hospital from January 1 , 1973 through August 31, 1975. Diagnosis was determined by clinical observation, aerology and bacteriology, eighty patients were treated medically, the remaining 16 patients required surgical intervention. The following results were obtained: 1) The age distribution of the patients revealed that 33.3% wert between 10 and 19 years old 21.9% were between 20 and 29, and 19.8% were between 30 and 39. The majority of patients were from these more active age groups. Male to female sex ratio was 1.3 : 1 2) Seasonal distribution was observed. Most illness occurred in the summer and autumn month 5. 3) 84. 3%of the patients came from farm families. 4) Duration between onset and admission averaged 16.0 days. The group without compilations was admitted after an average of 15. 1 days; The group with complications was ad-matted after an average of 19.4 days. 5) Methods of treatment before admission were as follows: 10.4% at medical clinics, 61, 5% at pharmacies (antibiotics 47.9%, other. drugs 13.5%), 7.3% by herb medications, 20.8% had no treatment. 6) Main clinical symptoms were as follows: fever 93.8%, headache 47.9%, abdominal pain 47.9%, chills 38.5%, cough 36.5%, general weakness 26.0%, nausea e vomiting 24.0% and generalized pain 21.9%. 7) Temperature of patients on admission: 22.9% were 39f or more, 67.6% were between 37℃ and 38℃, and 9.4% were 37℃ or less. 8) Occurrence of intensional bleeding after onset of disease averaged 9.3 days; perforation occurred at an average of 19. 1 days. 9) Interval between onset of major complication and surgical intervention averaged 2.8 days. 10) Among the 68 patients who underwent the bacteriological test the positive rate was 44.1% (30). The positive ,ales to, each separate culture method were as follows: 20.4% in the blood culture, 40.4% in the stool culture and 6.7% in the urine culture. Among these bacteriological positive patients 15 patients had a negative results or less than 160 titer of vidal reaction. 11) The initial vidal test of the total group showed a counts of 160 titer or more in 60.4% and less than 160 titer in 39.6%, 12) W. B. C. Counts in the uncomplicated group indicated that 32.5% were 6,000/㎣ or less, 47.5% were between 6,000 and 10,000, arid 20.0% were 10,000/㎣ or more. In the complicated group, 37.6% were 6,000/㎣ or less, 25,0% were 6,000-10,000/㎣ and 37.6% were 10,000/㎣ or more. 13) Duration of hospital stay of the patients averaged 6.4 days in the uncomplicated group and 12.7 days in the complicated group. 14) Subdiaphragmatic free air simple X-ray was found in 91.7% of the perforated cases. 15) Duration of antibiotic therapy until an febrile state was attained averaged 4.8 days in the uncomplicated group and 6.5 days in the complicated group. 16) Operative procedures were as follows: one layer simple closure of their perforation with or without debasement in 56.3%, drainage only in 6.3%, small bowel resection with primary anastomosis in 18.8% , externalization in 6.3%, cholecystectomy in 6.3%, The clinical findings of this study suggest the following recommendations. According to Top's report; 1% of typhoid fever patients treated with chlorarnphenicol and 2% of patients treated with other drugs become chronic carriers. Therefore, importance should be given to the strict control of these carriers. Immunization, improvement of sanitation and living standards are all needed for the prevention and treatment of disease, but a more serious problem is a lack of knowledge on the part of patients and their families. Thus it is most urgent to enlighten the citizens about the transmission and hygiene related to contagious disease. Legal restriction of sale of antibiotics at drug stores without a physician's prescription is an urgent matter for public health administrators. An even more important nursing responsibility is the reemphasis on health education both in the clinical setting and in the home.

  • PDF

A Quality Assurance Study for the Application of Cook/Chill System in School Foodservice Operation (II) - Pork Bulgogi (Broiled Sliced Pork with Sauces) - (학교급식에 Cook/Chill System 적용을 위한 품질보증연구(II) - 돼지불고기 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.319-331
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point plan applicable to cook/chilled Pork Bulkogi (broiled sliced pork with sauces) in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. During the product flow, time-temperature profile was recorded and microbiological analyses including mesophilic and psychrotrophic total plate counts, coliform, and fecal coliform and qualitative analyses of Salmonella and Listeria monocytogenes were done. Chemical analyses (pH, acid value, total volatile basic nitrogen), sensory evaluation, and quantitative analysis of thiamin were conducted for 5 days of chilled storage. The number of mesophiles in raw pork ($4.26{\pm}0.11\;Log\;CFU/g$), seasoning mixture ($5.97{\pm}O.04\;Log\;CFU/g$) and marinated pork ($5.56{\pm}0.21\;Log\;CFU/g$) were below the microbial standards for "requires further cooking" food items. Listeria monocytogenes was detected in seasoning mixture. After heating, the number of mesophiles ($5.17{\pm}0.04\;Log\;CFU/g$) were slightly reduced but it did not meet the microbial guidelines of $5\;Log\;CFU/g$ for "ready-to-eat" foods. No other microbes including pathogens were detected. By reheating the menu item after chilled storage, the number of mesophiles were reduced in every phase of 1st day ($4.62{\pm}0.22\;Log\;CFU/g$), 3rd day ($4.55{\pm}0.20\;Log\;CFU/g$) and 5th day ($4.25{\pm}0.16\;Log\;CFU/g$) of chilled storage, and the number of microbes was below the standard limits for "ready-to-eat" foods. At the fifth day of chilled storage, pH (p<0.05), acid value (p<0.01) and TVBN (p<0.05) showed significant increases. Sensory evaluation results did not show any significant change for 5 days of chilled storage. Thiamin content showed a decrease for 5 days of chilled storage. Consequently, the ideal shelflife recommended for Pork Bulkogi was within 3 days of chilled storage. CCPs for Pork Bulkogi were purchasing and receiving of raw meat and some seasoning ingredients, heating, chilling, chilled storage, reheating, and distribution.

  • PDF

Microbiological Hazard Analysis in Children Snacks around Schools (학교 주변 어린이기호식품의 미생물학적 오염도 평가)

  • No, Byung-Jin;Choi, Song-Yi;Kim, Soo-Chong;Lee, Dong-Ho;Seo, Il-Won;Ho, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.182-185
    • /
    • 2011
  • This study was conducted to develop an appropriated management for safety of children snacks sold around school. Total 598 items as targeted food were collected; 66 biscuits, 320 candies, 57 chocolates, 40 ice creams and 115 beverages. Microbiological hazards such as total aerobic bacteria, Coliforms, Escherichia coli, Bacillus ceruse, Yeasts & molds were measured by analytical method in Korean food code. Total aerobic bacteria and Yeasts & molds were detected in cookies at the level of less than 2.69 and 2.65 $log_{10}$ CFU/g and the detection rates were 54.55 and 62.12%, respectively. Bacillus cereus was detected in 1 snack only at the level of 1.39 $log_{10}$ CFU/g but it was less than Korean microbial standards and specifications (3 $log_{10}$ CFU/g). Total aerobic bacteria and Yeasts & molds were detected in candies less than 2.86, 3.36 $log_{10}$ CFU/g and the detection rates were 46,8% respectively. Total aerobic bacteria, Yeast & mold were detected in chocolates at the levels less than 2.52 and 1.87 $log_{10}$ CFU/g and the detection rates were 33 and 22% respectively. Total aerobic bacteria in both ice creams and beverages were detected at the levels less than 3.39 and 1.35 $log_{10}$ CFU/g and the detection rates were 82 and 5% respectively. Coliforms were found in one ice cream (1.39 $log_{10}$ CFU/g) only. The result of this study indicated that all children snacks around school were suitable for microbial standard and specifications in Korean Food Code. However, since most children snacks around school are circulated without proper storage temperature and handing condition, consistent microbial management for children snacks are needed.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Investigation of the Lactic Acid Bacteria Content of Probiotic and Lactic Acid Bacteria Products: a Study on Changes in the Preservation Method of Probiotic Products (프로바이오틱스와 유산균 제품의 균수 함량과 보존방법에 따른 변화 연구)

  • Kim, Young-Su;Hwang, Sun-Il;Kim, Sang-Tae;Han, Na-Eun;Kim, Hye-Young;Kim, Hyun-Soo;Park, Kwang-Hee;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.6
    • /
    • pp.474-482
    • /
    • 2018
  • The aim of this study was to determine and analyze probiotic contents, pH, and acidity of 120 samples of health functional and processed foods containing lactic acid bacteria distributed in 2017. The changes due to the preservation methods were also determined and analyzed in five probiotic products. Two samples of the 85 health functional food products had lactic acid bacteria at lower levels than the marked amount required to meet Korean food standards, whereas the 35 processed products were all suitable for distribution. The averages for probiotic contents, pH, and acidity were $1.2{\times}10^{10}CFU/g$, 5.35, and 1.29%, respectively. The average count of lactic acid bacteria in the 17 samples with marked amount among the 35 processed foods was $5.8{\times}10^8CFU/g$. The effects of preservation temperature ($-20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$, and $40^{\circ}C$) and storage period (1, 3, and 6 months) on probiotic content, pH, and acidity were determined for 5 probiotic products. After 1 to 6 months, the average reduction in probiotic content was by 59%; the lowest reduction occurred at $4^{\circ}C$ and the highest reduction occurred at $40^{\circ}C$. In addition, 3 of the 5 products showed a rapid decrease in probiotic content by more than 70% at $40^{\circ}C$ after a storage period of 1 to 3 months. Therefore, from this study results, it is recommended that products containing lactic acid bacteria should be refrigerated and consumed shortly after purchase.

A Study on Flammability Risk of Flammable Liquid Mixture (가연성 액체 혼합물의 인화 위험성에 관한 연구)

  • Kim, Ju Suk;Koh, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.701-711
    • /
    • 2020
  • Purpose: In this study, the risk of flammability of a liquid mixture was experimentally confirmed because the purpose of this study was to confirm the increase or decrease of the flammability risk in a mixture of two substances (combustible+combustible) and to present the risk of the mixture. Method: Flash point test method and result processing were tested based on KS M 2010-2008, a tag sealing test method used as a flash point test method for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was Japan's TANAKA. The flash point was measured with a test equipment that satisfies the test standards of KS M 2010 with equipment produced by the company, and LP gas was used as the ignition source and water as the cooling water. In addition, when measuring the flash point, the temperature of the cooling water was tested using cooling water of about 2℃. Results: First of all, in the case of flammable + combustible mixtures, there was little change in flash point if the flash point difference between the two substances was not large, and if the flash point difference between the two substances was low, the flash point tended to increase as the number of substances with high flash point increased. However, in the case of toluene and methanol, the flash point of the mixture was lower than that of the material with a lower flash point. Also, in the case of a paint thinner, it was not easy to predict the flash point of the material because it was composed of a mixture, but as a result of experimental measurement, it was measured between -24℃ and 7℃. Conclusion: The results of this study are to determine the risk of mixtures through experimental studies on flammable mixtures for the purpose of securing the effectiveness of the details of the criteria for determining dangerous goods in the existing dangerous goods safety management method and securing the reliability and reproducibility of the determination of dangerous goods Criteria have been presented, and reference data on experimental criteria for flammable liquids that are regulated in firefighting sites can be provided. In addition, if this study accumulates know-how on differences in test methods, it is expected that it can be used as a basis for research on risk assessment of dangerous goods and as a basis for research on dangerous goods determination.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

Effects of Dry Heat Treatment on the Reduction of Main Food-Borne Bacteria on Alfalfa Seeds (건열처리를 이용한 알팔파의 주요 식중독균 저감화)

  • Hong, Soon-Young;Kim, Su-jin;Bang, Woo-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.4
    • /
    • pp.225-231
    • /
    • 2022
  • In this study, the conditions of dry heat treatment (21 days at 65℃, 16 days at 70℃, 10 days at 75℃, and 7 days at 80℃) were investigated to inactivate Bacillus cereus ATCC 12480, Listeria monocytogenes ATCC SSA81, Staphylococcus aureus ATCC 6538, Escherichia coli O157:H7 ATCC 43894, and Salmonella Typhimurium ATCC 14028 on alfalfa seeds, without affecting the rate of germination of seeds. Alfalfa seeds were inoculated at levels of 6-7 log CFU/g and treated with dry heat at 65℃, 70℃, 75℃, and 80℃; thereafter, the rate of seed germination was determined. The rate of germination was set at 70%, according to the market standards. The bacteria were inactivated when B. cereus was treated with dry heat for 21 days at 65℃, 18 days at 70℃, 14 days at 75℃, and 4 days at 80℃; L. monocytogenes was treated for 21 days at 65℃, 18 days at 70℃, 12 days at 75℃, and 7 days at 80℃; S. aureus was treated for 18 days at 65℃, 18 days at 70℃, 11 days at 75℃, and 4 days at 80℃; E. coli O157:H7 was treated for 21 days at 65℃, 18 days at 70℃, 12 days at 75℃, and 6 days at 80℃; and Sal. Typhimurium was treated for 24 days at 65℃, 22 days at 70℃, 14 days at 75℃, and 7 days at 80℃. For all bacteria, the D-value (R2 = 0.5656-0.7957) significantly decreased when the temperature increased from 65℃ to 80℃ (P<0.05). Since dry heat treatment of alfalfa seeds at 80℃ for 7 days affects their germination rate, dry heat treatment at 75℃ for 14 days is the most effective way to ensure their safety. This study suggests a potential method of bacterial inactivation using dry heat treatment to increase the microbiological safety of sprouts.