• Title/Summary/Keyword: temperature standards

Search Result 885, Processing Time 0.026 seconds

Concrete Crack Detection Inside Finishing Materials Using Lock-in Thermography (위상 잠금 열화상 기법을 이용한 콘크리트 마감재 내부 균열 검출)

  • Myung-Hun Lee;Ukyong Woo;Hajin Choi;Jong-Chan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.30-38
    • /
    • 2023
  • As the number of old buildings subject to safety inspection increases, the burden on designated institutions and management entities that are responsible for safety management is increasing. Accordingly, when selecting buildings subject to safety inspection, appropriate safety inspection standards and appropriate technology are essential. The current safety inspection standards for old buildings give low scores when it is difficult to confirm damage such as cracks in structural members due to finishing materials. This causes the evaluation results to be underestimated regardless of the actual safety status of the structure, resulting in an increase in the number of aging buildings subject to safety inspection. Accordingly, this study proposed a thermal imaging technique, a non-destructive and non-contact inspection, to detect cracks inside finishing materials. A concrete specimen was produced to observe cracks inside the finishing material using a thermal imaging camera, and thermal image data was measured by exciting a heat source on the concrete surface and cracked area. As a result of the measurement, it was confirmed that it was possible to observe cracks inside the finishing material with a width of 0.3mm, 0.5mm, and 0.7mm, but it was difficult to determine the cracks due to uneven temperature distribution due to surface peeling and peeling of the wallpaper. Accordingly, as a result of performing data analysis by deriving the amplitude and phase difference of the thermal image data, clear crack measurement was possible for 0.5mm and 0.7mm cracks. Based on this study, we hope to increase the efficiency of field application and analysis through the development of technology using big data-based deep learning in the diagnosis of internal crack damage in finishing materials.

The Effects of Various Vegatable Pesticides on Materials of Cultural Property - Dyed and Undyed Silk Fabrics, Cotton Fabrics and Korean Papers, Undyed Ramie Fabric, Pigments, Painted Plates - (식물에서 추출한 살충.살균제가 문화재 재질에 미치는 영향 - 견직물, 면직물, 저마직물, 한지, 안료분말, 채색편 -)

  • Oh, Joon-Suk
    • Journal of Conservation Science
    • /
    • v.20
    • /
    • pp.9-22
    • /
    • 2007
  • Three kinds of natural pesticides extracted from plants which are being sold in the Korean markets, were estimated effects on materials of art of museum. Tested samples were 1) silk fabrics : undyed, dyed(amur cork tree, gallut, gallut(alum post mordancy), gallut(copperas post mordancy), gardenia, turmeric, acorn, acorn(copperas post mordancy), gromwell, madder, madder(alum post mordancy), safflower, sappanwood, sappanwood(alum pre mordancy, post mordancy), indigo, indigo+amur cork tree, indigo+sappanwood) 2) cotton fabrics : undyed, dyed(amur cork tree, gallut, gallut(alum post mordancy), gardenia, acorn, acorn(copperas post mordancy), gromwell, madder, madder(alum post mordancy), safflower, sappanwood, sappanwood(alum pre mordancy, post mordancy), indigo, indigo+sappanwood) 3) undyed ramie fabric 4) Korean papers : undyed, dyed(sappanwood, indigo, gardenia, amur cork tree, safflower) 5) pigments : azurite, malachite, red lead, litharge, orpiment, hematite, iron oxide, cinnabar, vermilion, indigo, lake indigo, kaolin, lead white, oyster shell white 6) painted plates : azurite, malachite, red lead, litharge, orpiment, hematite, iron oxide, cinnabar, vermilion, indigo, lake indigo, kaolin, lead white, oyster shell white. Conditions of tests were that after samples were exposed to 10 times of promoted concentration for 9 months in relative humidity $55{\pm}1%$ and temperature $20{\pm}2^{\circ}C$, they were compared with standards. Items of estimation were color difference(${\Delta}E^*$) and tenacity. After exposure to pesticides, undyed silk cotton ramie fabrics and Korean papers were not nearly changed in their colors, but colors of most of dyed samples were clearly changed by pesticides except for partial samples(acorn- and madder-dyed fabrics etc, gardenia-dyed samples). Especially changes of colors of turmeric-dyed silk fabrics were most distinct. And colors of pigments and painted plates containing lead, copper, arsenic, mercury and vegetable pigments, were clearly changed. Tenacities of yams of undyed silk fabrics were not nearly changed and undyed cotton fabrics were a little reduced as compared with standards. But tenacities of yams of dyed silk and cotton fabrics were clearly reduced or increased as compared with standards. Especially, madder-dyed silk fabrics were increased 10% or more and indigo-dyed silk fabrics were reduced 10% or less in all pesticides. Also madder- and sappanwood(alum post mordancy)-dyed cotton fabrics were increased 10% or more in all pesticides.

  • PDF

Comparison and Decision of Exposure Coefficient for Calculation of Snow Load on Greenhouse Structure (온실의 적설하중 산정을 위한 노출계수의 비교 및 결정)

  • Jung, Seung-Hyeon;Yoon, Jae-Sub;Lee, Jong-Won;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.226-234
    • /
    • 2015
  • To provide the data necessary to determine exposure coefficients used for calculating the snow load acting on a greenhouse, we compared the exposure coefficients in the greenhouse structure design standards for various countries. We determined the exposure coefficient for each region and tried to improve on the method used to decide it. Our results are as follows: After comparing the exposure coefficients in the standards of various countries, we could determine that the main factors affecting the exposure coefficient were terrain roughness, wind speed, and whether a windbreak was present. On comparing national standards, the exposure coefficients could be divided into three groups: exposure coefficients of 0.8(0.9) for areas with strong winds, 1.0(1.1) for partially exposed areas, and 1.2 for areas with dense windbreaks. After analyzing the exposure coefficients for 94 areas in South Korea according to the ISO4355 standard, all of the areas had two coefficients (1.0 and 0.8), except Daegwallyeong (0.5) and Yeosu (0.6), which had one coefficient each. In South Korea, the probability of snow is greater inland than in coastal areas and there are fewer days with a maximum wind velocity > $5m{\cdot}s^{-1}$ inland. When determining the exposure coefficients in South Korea, we can subdivide the country into three regions: coastal areas with strong winds have an exposure coefficient of 0.8; inland areas have a coefficient of 1.0; and areas with dense windbreaks have an exposure coefficient of 1.2. Further research that considers the number of days with a wind velocity > $5m{\cdot}s^{-1}$ as the threshold wind speed is needed before we can make specific recommendations for the exposure coefficient for different regions.

Simulation platform for living environment to ensure quality life (쾌적한 생활 설계를 위한 주거 및 사무실 시뮬레이터개발)

  • Park, Se-Jin;Kim, Chul-Jung;Kim, Si-Kyung;Mazumder, Mohammad Mynuddin Gani
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.853-860
    • /
    • 2007
  • In this modern era, human beings lead their life in complex environment where there are lots of parameters such as temperature, light, smell, sound, visual stimulus etc. that play important role for quality life. These parameters affect physical and mental behavior of a human being immensely. To ensure quality life the demand for quality products is always associated with human emotion and sensibility. Due to human sensibility and emotion involvement with quality life, the design stages of any kind of product must include some certain features related with emotion and sensibility. The cues for optimizing artificial environment are the physiological responses of human in that environment. The conventional approach of environmental physiology is to measure the relationship between environmental physical parameters and human psychological parameters under artificial conditions. Using that approach we tried to design an artificial environment for our daily lives and activities associated with both physiological and psychological behavior. We developed the technique to present the mock environment and software to measure and evaluate sensibility physiologically or psychologically and a simulator to measure and evaluate sensibility that can be utilized for large scale industrial production and design of environment. Simulator to measure and analyze human sensibility (SMAS) was constructed, which was utilized to estimate human sensibility and to simulate living and office environment.

  • PDF

Co Ion-implanted GaN and its Magnetic Properties

  • Kim, Woo-Chul;Kang, Hee-Jae;Oh, Suk-Keun;Shin, Sang-Won;Lee, Jong-Han;Song, Jong-Han;Noh, Sam-Kyu;Oh, Sang-Jun;Kim, Sam-Jin;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.11 no.1
    • /
    • pp.16-19
    • /
    • 2006
  • $2-\mu{m}$ thick GaN epilayer was prepared, and 80 KeV $Co^{-}$ ions with a dose of $3X10^{16}\;cm^{-2}$ were implanted into GaN at $350^{\circ}C$. The implanted samples were post annealed at $700^{\circ}C$. We have investigated the magnetic and structural properties of Co ion-implanted GaN by various measurements. HRXRD results did not show any peaks associated with second phase formation and only the diffraction from the GaN layer and substrate structure were observed. SIMS profiles of Co implanted into GaN before and after annealing at $700^{\circ}C$ have shown a projected range of $\sim390\AA$ with 7.4% concentration and that there is little movement in Co. AFM measurement shows the form of surface craters for $700^{\circ}C$-annealed samples. The magnetization curve and temperature dependence of magnetization taken in zero-field-cooling (ZFC) and field-cooling (FC) conditions showed the features of superparamagnetic system in film. XPS measurement showed the metallic Co 2p core levels spectra for $700^{\circ}C$-annealed samples. From this, it could be explained that magnetic property of our films originated from Co magnetic clusters.

Effects of Turbid Water on Fish Ecology in Streams and Dam Reservoirs

  • Seo, Jin-Won;Lee, Jong-Eun
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.4
    • /
    • pp.431-440
    • /
    • 2008
  • Turbid water or suspended sediment is associated with negative effects on aquatic organisms; fish, aquatic invertebrate, and periphyton. Effects of turbid water on fish differ depending on their developmental stage and a level of turbidity. Low turbid water may cause feeding and predation rates, reaction distance, and avoidance in fish, and it could make fish to die under high turbidity and long period. Therefore, it is very important to find out how turbid water or suspended sediment can affect fish in domestic watersheds. The objectives of this study were 1) to introduce international case studies and their standards to deal with suspended sediment, 2) to determine acute toxicity in 4 major freshwater fishes, and 3) to determine in relation to adverse effect of macroinvertebrates and fish. Impacts of turbid water on fish can be categorized into direct and indirect effects, and some factors such as duration and frequency of exposure, toxicity, temperature, life stage of fish, size of particle, time of occurrence, availability of and access to refugia, etc, play important role to decide magnitude of effect. A review of turbidity standard in USA, Canada, and Europe indicated that each standard varied with natural condition, and Alaska allowed liberal increase of turbidity over natural conditions in streams. Even though acute toxicity with four different species did not show any fatal effect, it should be considered to conduct a chronic test (long-term) for more detailed assessment. Compared to the control, dominance index of macroinvertebrates was greater in the turbid site, whereas biotic index, species diversity index, species richness index, and ecological score were smaller in the turbid site. According to histopathological analysis with gills of macroinvertebrate and fishes, morphological and physiological modification of gills due to suspended sediments can cause disturbance of respiration, excretion and secretion. In conclusion, in order to maintain good and healthy aquatic ecosystem, it is the best to minimize or prevent impact by occurrence of turbid water in stream and reservoir. We must make every effort to maintain and manage healthy aquatic ecosystem with additional investigation using various assessment tools and periodic biomonitoring of fish.

Estimation of The Global Warming Potential of Fluorinated Green House Gases (불화온실가스의 흡수단면적 측정을 통한 지구온난화지수의 추정)

  • Kim, Jihye;Lee, Jeongsoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.387-397
    • /
    • 2014
  • This work aims at estimating global warming potentials (GWP) of $CF_3Br$ and HFC-134a among green house gases. It has been reported that they have much higher GWP than $CO_2$ in the atmosphere. $CF_3Br$, halon 1301 which is well known to be a fire extinguisher, as one of the bromine-containing halons has been banned since 2003 due to destruction of ozone. HFCs, a kind of chiller which replaced chlorofluorocarbons (CFCs) are one of greenhouse gases regulated by the Kyoto Protocol. In this study, we produced GWPs of $CF_3Br$ and HFC-134a by calculating a life time and measuring an absorption cross section to obtain a radiative forcing (RF). Their absorption cross sections were measured by using Fourier-transformed infrared spectroscopy (FTS) with a gas cell filled with their certified reference materials at room temperature. As a result, the RFs of $CF_3Br$ and HFC-134a were 0.32 and $0.168Wm^{-2}ppb^{-1}$, respectively and the GWPs were calculated as 7989, 6076, 3903 for $CF_3Br$ and 3855, 1300, 656 for HFC-134a for the time horizon of 20, 100, 500 years, respectively. Overall, uncertainty of the estimated GWPs can be estimated to be about 2.6%. Our results were compared with those proposed by the previous studies (IPCC, 2007; WMO, 1999).

A Time-Series Study of Ambient Air Pollution in Relation to Daily Death Count in Daejeon, 1998-2001 (대전 광역시 대기오염과 일별 사망자 수의 상관성에 관한 시계열적 연구(1998년~2001년))

  • Cho, Yong-Sung;Lee, Jong-Tae;Kim, Yoon-Shin
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.1
    • /
    • pp.9-19
    • /
    • 2004
  • This study is performed to examine the relationship between air pollution exposure and mortality in Daejeon for the years of 1998 - 2001. Daily counts of death were analyzed by general additive Poisson model, with adjustment for effects of seasonal trend, air temperature, humidity, and day of the week as confounders in a nonparametric approach. Daily death counts were associated with CO(4 day before), $O_3$(current day), $PM_10$(4 day before), $NO_2$(6 day before), $SO_2$(2 day before). Increase of $31.07{\mu}g/m^3$(interquartile range) in $PM_10$ was associated with 2.0 % (95% CI = 0.5 % - 3.5 %)) increase in the daily number of death. This effect was greater in children(less than 15 aged) and elderly(more than 65 aged). We concluded that Daejeon had 2 - 4 % increase in mortality in association with IQR in air pollutants. Daily variations in air pollution within the range currently occurring in Daejeon might have an adverse effect on daily mortality. These findings also support the hypothesis that air pollution at levels below the current ambient air quality standards of Korea except PM10, is harmful to sensitive subjects, such as children or elderly.

Assessment and Corrective Measures of Child-care Foodservices by Sanitary Inspection Checklist Suggested by Korea Food and Drug Administration (식품의약품안전처의 위생점검표에 의한 육아지원기관 급식소 평가 및 개선대책)

  • An, Su-Jung;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.21 no.3
    • /
    • pp.227-240
    • /
    • 2015
  • The purpose of this study was to assess the hygiene status of 145 child-care foodservices, which were newly registered in the Center for the Children's Foodservice Management (CCFSM) in Changwon, Gyeongnam. Sanitary inspection checklist (40 food safety items) of Korea Food and Drug Administration (KFDA) was used by the CCFSM in Changwon, Gyeongnam. Average score from the total safety items in 145 child-care foodservices was 21.41 points out of 40 points. Score gaps between the lower group (71 foodservices, 13.92 points) and higher group (74 foodservices, 28.61 points) showed a significant difference (P<0.001). The top five priorities of sanitary measures needing corrective actions for child-care foodservices were as follows: 'provide hand washing and sanitizing tools, and supply manuals on how to wash hands properly', 'supply record form for access/inspection', 'conduct education for cooks on standards in the selection of sanitizer for raw vegetables and proper methods to wash and sanitize raw vegetables', 'provide a refrigerator and a freezer with installed thermometers and temperature record monitoring logs', 'encourage separation of contamination operating zone and clean zone or conduct training for cooks on ways to prevent cross-contamination by performing work separately by the hour'. For the higher group, most were national/public facilities (83.3%), whereas in the lower group, private facilities (62.1%) were more common than national/public ones (37.9%). Therefore, a significant difference (P<0.001) was detected in the two groups. These private facilities should be supported.

Study of High-capacity Foam Discharging Systems for Full Surface Fire of Big Oil Tanks (대형 유류저장탱크 전면화재 대응을 위한 대용량포방사시스템 연구)

  • Im, Joo-Yeol;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.173-180
    • /
    • 2019
  • Oil tank fires need to be suppressed differently from other oil-related fires, due to the high-temperature flames and hot updraft above the tank, in the former case, that cause the destruction of large amounts of foam. We studied high-capacity foam discharge systems based on the standards of the American Petroleum Institute (API), National Fire Protection Association (NFPA), British Standard European Norm (BS EN), and the laws of Japan. The performance of a high-capacity foam discharge system was measured by conducting real fire experiments with model oil tanks. We concluded that lightweight and easily movable high-capacity foam discharge systems should be urgently introduced in domestic operations. Additionally, the obstacles faced by major tanks, such as long-distance installation of large-diameter fire hoses and narrowing of firefighting spaces, should be resolved depending on the conditions of the site.