• Title/Summary/Keyword: temperature standards

Search Result 885, Processing Time 0.032 seconds

Defect Measurement of Graphites for High Temperature Application by AE Technique (AE 계측에 의한 고온용 흑연재료의 경함측정에 관한 연구)

  • Choe, Man-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-127
    • /
    • 1992
  • In this study, we investigated defects of graphite by three NDT methods which are ultrasonic testing at 5 MHz, micro-forused X-ray testing and AE testing. As the detection of AE signals generated from graphite tensile specimens, we calculated location of AE sources and compared them with UT and X-ray test results in detecting defects of several specimens, Acoustic emission testing could be applied to some graphites which have fine grains of a few tens of micrometer, but it was difficult to those in lager grain of few fo milimeter. Also, we could understand what kind of defects has affected on tensile fracture of graphite.

  • PDF

Reliability assessment test for heavy sluice gate of hydraulic cylinder (수문용 대형 유압실린더의 신뢰성 평가)

  • 이용범;현동수;김형의;이근호;정동수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.91-97
    • /
    • 2001
  • These Study are for the development of the reliability assessment test code and test equipment and test procedures of the heavy sluice gate hydraulic cylinder. Because there is no reliability test code for the heavy sluice gate hydraulic cylinder inside and outside of the country, the modified reliability test code is made reference for the related existing standards like as ISO, JIS, MIL, TUV, DIN, KS and etc. In this study, the novel method is proposed to evaluate efficiency of the heavy sluice gate hydraulic cylinder on the loading conditions and established the conditions of the acceleration life test to reduce the testing time and cycles. The testing equipments for life test, lode operating test, high and low temperature test and salt spray test have been established for 8 month, and the reliability tests are accomplished. The test results of the heavy sluice gate hydraulic cylinder which is produced and tested initially in Korea are satisfied the durability life cycle on the using conditions.

  • PDF

Performance Tests of Epoxy-Coated Reinforcing Bars (에폭시 도막철근의 성능 실험연구)

  • 최완철;김채훈;신영수;홍기섭;홍영균;정일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.158-162
    • /
    • 1994
  • Test results to evaluate the mechanical properties of epoxy-coated bars and corrosion protection characteristics of epoxy coating on the bars are described. The results show good adhesion and abrasion resistance satisfying the requirements in relevant standards. The test results also show that for a coating thickness ranging from 150${\mu}{\textrm}{m}$ to 300${\mu}{\textrm}{m}$, satisfactory results are obtained regarding bendability. Cautions shall be required when bending epoxy-coated bars at a high bending degree and at a low temperature. The results of accelerated corrosion tests show good corrosion resistance. However, surface defects from the steel itself and insufficient blast-clean process form weak points resulting blistering or disbonding of the coating. The use of epoxy-coated bars is expected to help protect corrosion of reinforcement and extend the service life of reinforced concrete structures.

  • PDF

An Experimental Study on Calibration Method of Heat Flux Sensor by using Helium Gas (헬륨을 이용한 열유속센서 검정방법의 실험적 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1219-1224
    • /
    • 2004
  • The objective of this study is to propose an experimental calibration facility in which a heat flux sensor can be calibrated under conductive condition by using helium gas. The heat flux calibration facility was designed, simulated and manufactured for use in a high heat transfer condition. It delivers heat fluxes up to a maximum of 35 KW $m^{-2}$. A copper block heated electrically with 3.5 KW power is designed to produce uniform temperature up to 600 K across its face. High heat fluxes are provided between hot plate and cold plate by 1 mm height helium filled gap. A cold plate is maintained around 300 K through pool boiling using a refrigerant and water-cooled heat exchanger. A simulation was conducted to verify the design of the main test section. To verify the performance of calibration facility, a heat flux sensor was examined. The measured heat fluxes were compared to the calculated one.

  • PDF

Analysis on Activation Energy Measurement and Application of Nuclear Equipment Non-metallic Materials (원전기기 비금속재료의 활성화에너지 측정 및 적용성 분석)

  • Bhang, Keug-Jin;Hong, Jun-Hee
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.38-43
    • /
    • 2016
  • Safety-related equipments of Nuclear Power Plants(NPP) have to perform environmental qualification test in accordance with IEEE-323 standards. However, non-metallic materials replace new one regularly instead of the test because they are considered as consumable parts. In this study, the seven kinds of non-metallic materials are selected and their activation energy was experimentally evaluated with uncertainty analysis by using thermogravimetric analyzer(TGA). In order to obtain activation energy of non-metallic materials, mass difference, temperature raising rate and conversion rate on the specimen are analyzed. It is postulated that the three experiment conditions are important to get a reliable activation energy. This postulate was experimentally confirmed using Arrhenius equation and Flynn-Wall-Ozawa analysis.

Quantitative analysis of 5-HMF produced from fructose (과당에서 전환된 5-HMF(5-hydroxymethylfurfural)의 정량적 분석)

  • Sim, Jaehoon;Shin, Soo-Jeong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.1
    • /
    • pp.27-34
    • /
    • 2013
  • Quantitative analysis of 5-hydroxymethylfufural (5-HMF) conversion from fructose by dehydration and rearrangement was investigated by $^1H$-NMR spectroscopic method. Fructose was converted to 5-HMF in dimethylsulfoxide (DMSO)-$d^6$ or acidic deuterium hydroxide at controlled reaction temperature and time. With addition of internal standards (biphenyl for DMSO-$d^6$ solvent, and 2,5-dihydroxybenzoic acid for deuterium oxide solvent), conversion from fructose to 5-HMF was analyzed by $^1H$-NMR spectroscopy. Quantitative analysis was run by comparison with peak area integration between of 5-HMF and internal standard. In DMSO solvent, 5-HMF was stable end product but part of 5-HMF was converted to formic and levulinic acid at acidic aqueous medium.

Characteristics of Formaldehyde Concentrations in the Underground Spaces in Gyungnam Province (경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성)

  • Ha Kwon Chul
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.353-357
    • /
    • 2004
  • The purpose of this research is to characterize formaldehyde as trace toxic air pollutant in the underground spaces in Gyungnam province. Air samples of formaldehyde were taken in the three underground spaces for ten months from April 2003 to January 2004. The IAQ(Indoor Air Quality) of underground spaces were controled using central ventilation(supply/exhaust) system. The levels of GM of airborne formaldehyde concentrations in three sampling spaces were well below applicable standards, Korean Ministry of Environment, 0.1 ppm. However, some sample of airborne formaldehyde concentrations in underground spaces 'B' and 'C' were in excess of standard, due to the commercial products in shop, structural material, and the climate having high humidity and temperature. There are statistical differences in levels of formaldehyde by sampling spaces (p=0.086).

A Study on the Electrical and Thermal Safety of System LED Lighting (시스템 LED 조명의 전기적·열적 안전성 확보 방안에 대한 연구)

  • Kim, Yeong Woo;Kim, Chung Hyeok;Choi, Woon Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.418-426
    • /
    • 2020
  • This study tested the electrical, structural, and thermal safety of LED lighting products, available on the market. Five recessed LED systems, 20 W each, and five fixed LED systems, 25 W each, were selected. Dielectric strength tests, live part electric shock protection tests, and thermal tests were conducted on the LEDs. These were key tests for user safety, according to the specification of the safety criteria for electric products, KC 60598-1, South Korea. In addition, the wiring temperature of UL1007, 60227 IEC 08, and UTP cables, was measured. The results of the study gave an in-depth examination of the safety of LED lighting systems for users.

CONCENTRATION DEPENDENCES OF GROUND-STATE AND EXCITED-STATE INTRAMOLECULAR PROTON TRANSFER OF PIROXICAM IN METHANOL

  • Cho, Dae-Won;Kang, Seong-Gwan;Kim, Yong-Hee;Yoon, Min-Joong;Kim, Dong-Ho
    • Journal of Photoscience
    • /
    • v.1 no.1
    • /
    • pp.15-23
    • /
    • 1994
  • The absorption and fluorescence spectral properties of piroxicam (PRX) in the hydrogenbonding solvents show the most sensitive dependence on the concentration ranging from 8 x 10$^{_5}$ to 2 x10$^{_5}$ M. These are attributed to both the solvent-mediated ground-state intermolecular proton transfer (GSIerPT) leading to formation of the ground state anion and the excited-state intmmolecular proton transfer (ESIraPT). The concentration dependences of the time-resolved emission kinetics at both room temperature and 77 K have also been investigated. It is shown that in the excited state, the ESIraPT of PRX is the dominant process to form a keto tautomer at the high concentration, whereas at the low concentration the excited-state conformational change of the anion is an additional process leading to formation of a zwitterion. The ESI~PT of PRX in the hydrogenbonding solvent is coupled with the ultrafast excited-state solvent reorganization.

  • PDF

Quality Evaluations of Induction Motors Bracket Castings during Fabrication Processes (유도전동기 브라켓 제작시 품질평가)

  • Park, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5474-5479
    • /
    • 2014
  • This study evaluated the residual stress and deformation for bracket castings of induction motors. Numerical analyses were performed to evaluate the residual stress distributions and displacements of bracket castings after the casting and final machining processes. Based on the analysis results, it was found that bracket casting was satisfied with the internal quality standards during the fabricating processes.