• Title/Summary/Keyword: temperature standards

Search Result 885, Processing Time 0.033 seconds

Feasibility Study of IEEE 802.15.4 LR-WPAN to the Real-time Voice Application (IEEE 802.15.4 LR-WPAN의 실시간 음성 데이터 응용에 대한 적용 가능성 연구)

  • Hur, Yun-Kang;Kim, You-Jin;Huh, Jae-Doo
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.2 no.2
    • /
    • pp.82-94
    • /
    • 2007
  • Wireless sensor networking technology is one of the basic infrastructures for ubiquitous environment. It enables us to gather various sensory data such as temperature, humidity, gas leakage, and speed from the remote sensor devices. To support these networking functions, IEEE WPAN working group makes standards for PHY and MAC, while ZigBee Alliance defines the standards for the network, security, and applications. The low-rate WPAN was emerged to have the characteristics of network resilience, low cost, and low power consumption. It has a broad range of applications including, but not limit to industrial control and monitoring, home automation, disaster forecast and monitoring, health care. In order to provide more intelligent and robust services, users want voice-based solutions to accommodate to low-rate WPAN. In this paper, we have evaluated voice quality of an IEEE 802.15.4 standard compliant voice node. Specifically, it includes the design of a voice node and experiments based on the prediction of voice quality using the E-model suggested by ITU-T G.107, and the network communication mechanisms considering beacon-enabled and nonbeacon-enabled networks for real-time voice communications.

  • PDF

Characteristics of 15 kVA superconducting fault current limiter (15 kVA급 저항형 초전도 한류기의 전류제한특성)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.272-275
    • /
    • 2000
  • We investigated a resistive superconducting fault current limiter (SFCL) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 Ap, was produced and successfully tested at a 220 V circuit. From the resistance increase, we estimated that the film temperature increases to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V.

  • PDF

The Effect of Complex Korean Medical Treatment on a Spinal Cord Tumor: Focused on Changes of Pain and Temperature Sensation and Pain Sensation (척수종양 환자에 관한 한방 복합치료 효과: 통증과 냉온통각 변화를 중심으로)

  • Park, Gi Nam;Kim, So Yun;Kim, Kyung Min;Kim, Hyun Ji;Kim, Eun Seok;Kim, Young Il
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.229-236
    • /
    • 2015
  • Objectives : The purpose of this study is to report the clinical effect of Korean medical treatment on a spinal cord tumor. Methods : We treated a patient who was diagnosed with a spinal cord tumor. We used acupuncture, bee venom pharmacopuncture, herbal medicine, moxibustion and physical therapy; the patient was evaluated using the visual analogue scale(VAS) and given an International Standards for Neurological Classification of Spinal Cord Injury(ISNCSCI) score. Results : VAS decreased and ISNCSCI score increased meaningfully. Conclusions : According to these results, this report possibly suggests that Korean medical treatment could be a helpful choice for treating a spinal cord tumor.

A Study on the Problem and Improvement of the Fire Detector Test in the Field (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Ok, Kyung-Jea;Cha, Ha-Na;Kim, Shi-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.180-184
    • /
    • 2008
  • Fire prevention strategies should be aimed at the prevention of structured fire since average annual rates of structured fire have been increased due to economic growth resulted in increasing high rise buildings and multipurpose occupancies over the past ten years. Hence, this study mainly focused on the improve method and problems in the field test of fire detector in compliances with experimental consideration. And it leads us to the flowing conclusions : Firstly, it is necessary to formulate a safety standards on field test. Nowadays, the test enforced in many ways without formulated standard. Therefore it is necessary to be complete the arrangements standardized and how to do the test with formulated safety standards. Second, it is necessary to establish the regal guidance with regard to inspection equipment, ie density, component and temperature of test equipment should be considered. Also the equipment is need to be standardized and improved. Third, fire inspector's competency in their practice should be enhanced. The problems arising from the lack of knowledge and competence regarding inspection could be settled by providing professional education to ensure proficiency in their practice. Specialized training, as has been noted, should be offered in accordance with occupancy type, scale and fire protection system in the fire facilities.

  • PDF

Development of Superconducting Transition Edge Sensors for Gamma Ray Detection (감마선 검출을 위한 초전도 상전이 센서)

  • Lee, Young-Hwa;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.162-166
    • /
    • 2008
  • We are developing a sensitive gamma ray spectrometer based on superconducting transition edge sensors. The detector consists of a small piece of high purity Sn as an absorber and a Ti/Au bilayer as a temperature sensor. It is designed to measure the thermal signal caused by absorption of gamma rays. The mechanical support and the thermal contact between the absorber and the thermometer were made with Stycast epoxy. The bilayer was formed by e-beam evaporation and patterned by wet etching on top of a $SiN_X$ membrane. A sharp superconducting transition of the film was measured near 100 mK. When the film was biased to the edge of the transition, signals were observed due to single photon absorption emitted from an $^{241}Am$ source. The measured spectrum showed several characteristic peaks of the source including 59.5 keV gamma line. The full with at half maximum was about 900 eV for the 59.5 keV gamma line. The background was low enough to resolve low energy lines. Considerations to improve the energy resolution of the gamma ray spectrometer are also discussed.

  • PDF

Structure and Suppression of Nonpremixed Counterflow Flames (비예혼합 대향류화염의 구조와 소화)

  • Anthony Hamins;Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.20-25
    • /
    • 2003
  • Measurements with filaments and thermocouples and computations with Oppdif and FDS were carried out to investigate the impact of flame strain, agent addition, and buoyancy on the structure and extinction of nonpremixed counterflow flames. Measurements through 2.2 s drop tests in microgravity conditions and experiments in normal gravity conditions were compared with the results of computations. For the global strain rates 7 s$^{-1}$ through 100 s$^{-1}$ , the turning point behavior in the critical nitrogen concentration at O-g was confirmed. The effects of buoyancy, that is, changes in the flame curvature and thickness were also confirmed by the computations with FDS. There was agreement in the peak flame temperature and its position between the computations and the measurements in the near extinction methane/air diffusion flames in microgravity.

The Characteristics of Water Quality in Mokpo Harbour(I) - Centering on organic pollution and dissolved oxygen in summer- (목포항의 수질 특성(I) - 하계의 유기물 오염과 용존산소를 중심으로 -)

  • 김광수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.1
    • /
    • pp.99-109
    • /
    • 1997
  • The in situ observations and the seawater analyses were conducted in July and August, 1996 for the purpose of describing the characteristics of organic pollution, dissolved oxygen distributions, and the evaluation of water quality in Mokpo harbour. The vertical density distribution of water column was found to be in stable structure with higher water temperature and lower salinity on surface layer at ebb tide in summer. In July, dissolved oxygen was shown to be oversaturated on surface and bottom layers, while in August, which was shown to be oversaturated on surface layer, and to be unsaturated on bottom layer as 68∼93% of saturation percentage. Dissolved oxygen of bottom layer in August was evaluated to be under the regular grades, based on Korean standards of seawater quality. In view of COD, the seawater quality of Mokpo harbour in summer was evaluated to be deteriorated due to organic wastes and graded to be the third class, and TSS of Mokpo harbour in summer was graded to be the second class, based on Korean standards of seawater quality. In particular, COD of surface layer in August was found to be under the regular grades. It is, therefore, necessary to take measures for the control of pollution loads and the proper management of seawater quality in Mokpo harbour. The distribution patterns of DO, COD, VSS and Chlorophyll-a on surface layer along the downstream center line from inner harbour to harbour entrance were similar to one another at ebb tide in August.

  • PDF

Indoor Environment of Inside Ancient Tomb with HVAC System (공조기를 적용한 고분내부 실내환경)

  • Lee, Kum-Bae;Jun, Hee-Ho;Ko, Seok-Bo;Park, Jin-Yang;Jun, Yong-Du
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.141-147
    • /
    • 2005
  • Although the importance of good conservation of historic sites including ancient royal tombs is wet] aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the general understanding about the environment of the underground space of tombs is not satisfactory. In the present study, vibration levels due to the operation of an HVAC system to maintain the desired indoor temperature and humidity are investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the indoor unit inside, showed order of magnitude less values than the Swiss Standards, but still higher than the value suggested by German standards, which is, zero. For the vibration level depends not only on the system design, but also on the installation methods, further study will be pursued for cases including different ways of installation.

  • PDF

Development Plans of Egg Industry Using International Comparison (국제비교를 통한 계란산업의 발전방안)

  • Kim, Yoon-Doo;Kim, Dong-Jin;Chae, Sue-Ho
    • Korean Journal of Poultry Science
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2020
  • The present study intended to analyze and detect any possible shortcomings in the current egg distribution system in Korea through a questionnaire. The institutional system and cases of operation thereof in advanced countries such as the USA, Japan, and Germany for the development of the egg distribution industry in Korea. The results revealed the following issues: absent pricing system, ineffective egg distribution, and difficulty in balancing supply and demand. Suggestions for addressing these issues and the subsequent improvement were based on cases found in the instated systems of advanced countries, and were given as follows: (i) The existing GP Center needs to be separated from the farms of laying hens, and the current institutional system and its operations need to be improved and should be approved by the government. Parallel to the institutional improvement, establishing a distribution system centered on the GP Center would be desirable. (ii) Egg pricing regulations are needed as a standard to determine the price of eggs. (iii) The reinforcing control standards and securing means for egg preservation are pertinent to each stage of egg distribution and should take into account environmental factors such as egg preservation temperature to guarantee high hygiene standards and egg safety.

Quench Characteristics of Resistive SFCL Elements in series (직렬 연결된 초전도 한류기의 퀜치 및 한류 특성)

  • Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Lim, Hae-Ryong;Kim, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.663-665
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter saphire substrates Two SFCLs with nearly identical properties were connected in series to investigate the simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference. however, resulted in significantly unbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resistor to an SFCL in parallel. The appropriate values of the shunt resistances were $80{\Omega}$ at $75 V_{rms}$. $100{\Omega}$ at $100 V_{rms}$ and $110{\Omega}$ at $120 V_{rms}$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation. but with increase in film temperature to higher than 200 K.

  • PDF