Study on Heat Treatment of Red Pine Log (소나무 원목의 열처리에 관한 연구)

  • Eom, Chang-Deuk;Han, Yeonjung;Shin, Sang Chul;Chung, Yeong Jin;Jung, Chan Sik;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.50-56
    • /
    • 2007
  • FAO standard for heat sterilization of wood, International standards for phytosanitary measures (ISPM) No.15, must meet heat-treated wood core temperature to be higher than $56^{\circ}C$ and keep the temperature for more than 30 minutes. This study was carried out to analyze the heat treatment characteristics of domestic pinewood sterilized with the FAO standard. To enhance the effectiveness of heat treatment process in mountainous district energy consumption and time required to reach target temperature were evaluated at various temperature and relative humidity conditions and moisture contents of wood. Heat-treatment of high temperature and high humidity reduced the required heating time. Lower humidity levels at same temperature reduced energy consumption per unit time. However, lower humidity levels could not reduce total energy consumption greatly because longer treatment time was required at that condition. It is necessary to estimate energy consumption and predict treatment time in dynamic heating and cooling situations, because it frequently happens not to meet optimum treatment condition due to poor surrounding climates and operation performance of heat treatment facility in real field.

A Study on the Microbiological Quality of Drinking Water and Changes During Storage

  • Kim, Jong-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.517-521
    • /
    • 2007
  • To assess possible risks from the consumption of drinking water from various sources, a survey of the microbiological quality of tap water, commercial bottled drinking water which is exploited from natural mineral water, and natural spring water was conducted. A total of 4 different brands of commercial bottled drinking water, and 4 types of spring water from different sources, and tap water from 4 private houses were tested for four index microorganisms, and the microbial quality changes of the water during the storage at room temperature or refrigerated temperature for 7 days. Aerobic plate counts of all of the initial water samples were still within 100 CFU/ml (drinking water standard of Korea). Total coliforms, fecal coliforms, and E. coli were not detected in all of the water samples at initial. However, aerobic plate counts of three types of spring water and three types of bottled drinking water stored at room temperature showed higher levels than the standards in 5 days. Total coliforms were detected in three types of spring water after one day's storage at room temperature, and in one type of bottled drinking water after 5 days' storage. These results indicate that some of the spring water surveyed are not safe to drink, and the spring water and bottled drinking water after opening the lid should not be stored at room temperature, if they are used for drinking.

Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer (여름철 사무실내 온열환경 특성 및 쾌적성 평가)

  • Lee, C.H.;Bae, G.N.;Choi, H.C.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

The Joining Quality of High Strength Bolt, Nut and Washer Set (S10T & 10.9HRC) under the Surface Treatment Conditions (표면처리별 S10T, 10.9HRC 고장력 볼트 세트의 체결 품질 연구)

  • Choi, Youn-O;Suk, Han-Gil;Hong, Hyeon-Sun
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.3
    • /
    • pp.93-99
    • /
    • 2015
  • This test focuses on the correlations between joining axial force at non-room temperature and at room temperature according to the surface treatment (Geomet, Dacro, Green Kote, Armore Galv.). The quality characteristics of the fastening axial force required by the KSB 2819 and EN14399-10 standards were discussed. Surface treatment was implemented to S10T and 10.9HRC sets of bolts under the same environmental factors. Development for the stabilization of the fastening axial force required by each standard should continually be enforced, and the fastening and storage in the field should be maintained at room temperature. Managing stabilization of torque enumerated data is required after application of surface treatment. It is concluded that, by conducting the test of applying surface treatment to effectively manage, each lot-specific rate of axial force at room temperature conditions should be maintained below the maximum 4.47%. The decline rate of axial force should be maintained under 2.15% maximum, and the standard deviation of the room temperature condition should be maintained below 0.5.

Design and Implementation of a Digital Control Unit for an Oxygenaire Servo Baby Incubator

  • Zahran, Mohamed;Salem, Mahmoud;Attia, Yousry;Eliwa, Aref
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.121-130
    • /
    • 2008
  • This paper introduces a design and implementation of a digital control unit for an Oxygenaire Servo Baby Incubator. The control unit is designed and implemented according to international standards. The control unit is based on an AVR Atmel microcontroller unit. It is built for monitoring and control and displays the three main temperature values: set point temperature, baby skin temperature and air temperature. User friendly software is implemented. The implemented control unit was tested in the laboratory as well as in the field. The control unit is sensitive to change of $0.1^{\circ}C$. At startup, based on a unique control strategy, the incubator reaches its steady state in about 14 minutes. The system schematic diagrams are shown in the paper. Also, programs flow charts are presented. The control unit was designed and implemented based on a contract between the Electronics Research Institute (ERI) and ENGIMED Company. The authors would like to thank ERI and ENGIMED for introducing all required finance and shoring to complete this work.

Torrefaction for Improving Quality of Pellets Derived from Calliandra Wood

  • Johanes Pramana Gentur SUTAPA;Ahmad Harun HIDYATULLAH
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.381-391
    • /
    • 2023
  • Densification is a technique used to improve biomass quality in wood pellet manufacturing and torrefaction treatment. In this study, the effects of torrefaction on the quality of Calliandra wood pellets were investigated, and pellets of Calliandra wood (Calliandra calothyrsus) and bark were evaluated. The study was conducted using a completely randomized design with two treatment factors, namely torrefaction temperature (250℃ and 300℃) and torrefaction duration (30, 45, and 60 min). The results showed that the interaction between temperature and torrefaction duration significantly affected the compressive strength, proximate value, and calorific value of the torrefied Calliandra wood pellets. An increase in the temperature and torrefaction duration decreased the compressive strength, moisture content, volatile matter content, and ash content of the torrefied Calliandra wood pellets. Conversely, the calorific value of Calliandra wood pellets increased with increasing temperature and torrefaction duration. The best-quality Calliandra wood pellets were produced at a torrefaction temperature and duration of 300℃ and 60 min, respectively. In terms of important quality parameters, ash content of 0.90% and calorific value of 6,303.80 cal/g were observed, which complied with the quality standards of Indonesian National Standard 8675:2018 and Deutsche Industrie Norm 51731.

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

Deposition of copper dots with new copper precursors (새로운 Copper 전구체를 이용한 구리점 증착)

  • Kang, Sang-Woo;Seong, Dae-Jin;Shin, Yong-Hyoen;Rhee, Shi-Woo;Yun, Ju-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.485-492
    • /
    • 2006
  • Two new copper(I) complexes with organic ligands, $[Cu^I(hfac)]_2(DVTMSO)$ and $[Cu^I(hfac)]_2(HD)$ (hfac=hexafluoroacetylacetonate, DVTMSO=1,2-divinylte-tramethyl-disiloxane, HD=1,5-hexadiene) were synthesized and used for copper metal-organic chemical vapor deposition. In these compounds, two Cu(hfac) fragments are bonded by one neutral ligand forming unusual structure with respect to other Cu(I) complexes. The compounds exhibited relatively high volatility and stability when compared to other copper(I) precursors. By using the reported compounds as precursors, a continuous Cu layer was not formed but the Cu islands were only observed. And the shape and size of Cu islands are significantly changed as a function of the substrate temperature.

Development of Liquid Density Measurement Sensor Using the Natural Frequency of a Pipe (파이프의 고유진동수를 이용한 액체밀도측정 센서개발)

  • Chang, Kyung-Ho;Lee, Yong-Jae;Kim, Kwang-Pyo;Ahn, Byung-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.9-14
    • /
    • 1995
  • For the development of liquid density measuring sensor using the natural frequency of a pipe, its principle and construction method were described. The stainless steel pipe, which has length of 32 cm, inside diameter of 2.3 cm and outside diameter of 2.5 cm, was used for the sensor. The exciting coil and the photo sensor were used to excite and to pick-up it, and the feedback circuit was designed to continue its vibrating. The natural frequency was consistent with the result of the spectrum analysis. It had a linearity of 0.0027 % and a sensitivity of 0.032 % in liquid density range from $0.8\;g/cm^{3}$ to $1.4\;g/cm^{3}$ and its frequency variation ratio was 0.024 $%/^{\circ}C$ in temperature range from $10^{\circ}C$ to $35^{\circ}C$.