• 제목/요약/키워드: temperature of dew point

검색결과 133건 처리시간 0.028초

고분자 제습로터의 저온재생 성능시험 (Performance Test of Low Temperature Regeneration Polymeric Desiccant Rotor)

  • 이진교;이대영;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.629-632
    • /
    • 2009
  • The polymeric desiccant rotor is made from the super absorbent polymer by ion modification. The moisture sorption capacity of the super desiccant polymer(SDP) is 4 to 5 times larger than those of common desiccant meterials such as silica gel or zeolite. It is also known that SDP can be regenerated even at the relatively low temperature. To fabricate the desiccant rotor, firstly the SDP was laminated by coating the SDP on polyethylene sheet. Then corrugated and rolled up into a rotor. The diameter, the depth, the dimensions of the corrugated channel, etc. were pre-determined from numerical simulation on the heat and mass transfer in the desiccant rotor. The dehumidification performance was tested in a climate chamber. The relevant tests were carried out at the process air inlet temperature of $32^{\circ}C$, the regeneration air inlet temperature of $60^{\circ}C$ and the inlet dew-point temperature of both the process air and the regeneration air of $18.5^{\circ}C$, when the rotation period is long, the moisture sorption is not effective. In the desiccant rotor developed in this study, the optimum rotation period is found about 350s at the regeneration temperature of $60^{\circ}C$. It was found from further experiments that the optimum rotation tends to decreases as the regeneration temperature increases. Meanwhile, the outlet temperature of the process air deceases monotonically as the rotation period increases.

  • PDF

Thermal Resistance and Condensation in the Light-frame Timber Wall Structures with Various Composition of Insulation Layers

  • Jang, Sang Sik;Lee, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권4호
    • /
    • pp.533-542
    • /
    • 2019
  • As energy costs increase, more people has become interested on energy efficiency and savings in residential buildings. The two main subjects related to energy in residential buildings are insulation and condensation. There are two approaches to prevent condensation; increasing air tightness and maintaining the temperature inside of the wall structure over the dew point, which is in turn related to insulation. Even though the Korean government has highlighted the importance of energy efficiency for residential housings, and in spite of the customers' demands, the timber construction industry is still using conventional light-frame construction without even trying to improve energy efficiency. In this study, various types and combinations of wall structures were tested under cold outdoor and warm indoor temperatures to analyse the temperature gradients and to determine the possible sites of condensation in the wall structures. In addition to the experimental tests, three theoretical models were developed and their estimations of temperature change through the wall structure were compared with the actual measurements to evaluate accuracy of the models. The results of the three models agree relatively well with the experimental values, indicating that they can be used to estimate temperature changes in wall structures. The theoretical analysis of different insulation layers' combinations show that condensation may occur within the mid-layer in the conventional light-frame wall structures for any combination of inner-, mid-, and outer-layers of insulation. Therefore, it can be concluded that the addition of an inner and outer insulation layer or increasing the thickness of insulation may not be adequate to prevent condensation in the wall structure without preventing penetration of warm moist air into the wall structure.

다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구 (A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2323-2327
    • /
    • 2010
  • 저온환경에서의 자동화 설비, 반도체, 제조공정 및 수분 접촉이 되는 화학생산 라인 공정 등의 수분 제거를 위하여 다층형 열교환기를 이용한 제습장치를 구성하였다. 이 장치의 주요구성은 핀 피치가 다른 증발기 4대, 2대의 압축기, 2대의 응축기 그리고 팽창밸브로 각각 제작되었다. 본 연구에서는 제 1 열교환기(증발기)의 전면 풍속을 변화시켜 제습기의 성능 특성을 분석하였다. 즉, 제1 열교환기의 정면 풍속을 1.0m/s에서 4.0m/s까지 0.5 m/s의 간격으로 증가시켜 각 측정지점에서 온도와 상대습도를 측정하여 엔탈피를 구하여 각 열교환기의 냉각능력을 구했다. 그 결과 제1 열교환기의 정면 풍속이 2.0 m/s에서 각 열교환기의 냉각능력이 가장 좋은 것을 알 수 있었다.

한반도 태양에너지 연구를 위한 일사량 자료의 TMY 구축 (The Generation of Typical Meteorological Year for Research of the Solar Energy on the Korean Peninsula)

  • 지준범;이승우;최영진;이규태
    • 신재생에너지
    • /
    • 제8권2호
    • /
    • pp.14-23
    • /
    • 2012
  • The TMY (Typical Meteorological Year) for the solar energy study is generated using observation data with 22 solar sites from KMA (Korea Meteorological Administration) during 11 years (2000-2010). The meteorological data for calculation the TMY are used solar radiation, temperature, dew point temperature, wind speed and humidity data. And the TMY is calculated to apply the FS (Finkelstein and Schafer) statistics and RMSE (Root Mean Squared Error) methods. FS statistics performed with each point and each variable and then selected top five candidate TMM months with statistical analysis and normalization. Finally TMY is generated to select the highest TMM score with evaluation the average errors for the 22 whole points. The TMY data is represented average state and long time variations with 22 sites and meteorological data. When TMY validated with the 11-year daily solar radiation data, the correlation coefficient was about 0.40 and the highest value is 0.57 in April and the lowest value is 0.23 in May. Mean monthly solar radiation of TMY is 411.72 MJ which is 4 MJ higher than original data. Average correlation coefficient is 0.71, the lowest correlation is 0.43 in May and the highest correlation is 0.90 in January. Accumulated annual solar radiation by TMY have higher value in south coast and southwestern region and have relatively low in middle regions. And also, differences between TMY and 11-year mean of is distributed lower 100 MJ in Kyeongbuk, higher 200 MJ in Jeju and higher 125 MJ in Jeonbuk and Jeonnam, respectively.

낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로 (Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir)

  • 박준상;임윤규;김규랑;조창범;장준영;강미선;김백조
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

서식지 특성에 따른 맹꽁이 개체수와 기상요인과의 관계 분석 (Relationship between Abundances of Kaloula borealis and Meteorological Factors based on Habitat Features)

  • 노백호
    • 한국환경복원기술학회지
    • /
    • 제19권3호
    • /
    • pp.103-119
    • /
    • 2016
  • This study aims to assess habitat feature on the large-scale spawning ground of the Boreal Digging Frog Kaloula borealis in Daemyung retarding basin of Daegu, and to analyze the relationships between species abundance and meteorological factors for each habitat. Fifty-seven(57) pitfalls were installed to collect species abundance of 4 survey regions, and high-resolution satellite image, soil sampling equipment, digital topographic map, and GPS were used to develop habitat features such as terrain, soil, vegetation, human disturbance. The analysis shows that the frog is most abundant in sloped region with densely herbaceous cover in southern part of the retarding basin. In the breeding season, lowland regions, where Phragmites communis and P. japonica dominant wetlands and temporary ponds distributed, are heavily concentrated by the species for spawning and foraging. Located in between legally protected Dalsung wetands and lowland regions of the retarding basin, riverine natural levee is ecologically important area as core habitat for Kaloula borealis, and high number of individuals were detected both breeding and non-breeding seasons. Temperate- and pressure-related meteorological elements are selected as statistically significant variables in species abundance of non-breeding season in lowland and highland regions. However, in sloped regions, only a few variables are statistically significant during non-breeding season. Moreover, breeding activities in sloped regions are statistically significant with minimum temperature, grass minimum temperature, dew point temperature, and vapor pressure. Significant meteorological factors with habitat features are effectively applied to establish species conservation strategy of the retarding basin and to construct for avoiding massive road-kills on neighboring roads of the study sites, particularly post-breeding movements from spawning to burrowing areas.

컨테이너형 ESS 화재방지를 위한 내부 응결점 개선 관한 연구 (Study on Improvement of Dew Point within ESS Container for Fire Prevention)

  • 김운학;강석원;신기석
    • 한국재난정보학회 논문집
    • /
    • 제15권2호
    • /
    • pp.165-174
    • /
    • 2019
  • 연구목적: 본 연구에서는 제안되는 ESS 컨테이너 화재사고의 원인들에 대한 상관관계를 확인하였다. 연구방법: 이들의 개선에 필요한 컨테이너 내부의 환경개선을 통하여 컨테이너 화재사고의 저감 가능성에 대한 조사를 시행하였다. 연구결과: 본 연구를 통해 내 외부 온도차에 발생되는 수분응결 조건의 개선과 이를 통한 BMS board의 절연 내력의 변화가 있음을 확인하였다. 연구결론: BMS Board 응결과 절연 내력저하와의 상관 관계를 확인하였다.

분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구 (An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System)

  • 장재철;강은철;정시영;박성룡
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

Estimation of Probable Maximum Precipitation in Thailand Using Geographic Information System

  • Kingpaiboon, Sununtha;Netwong, Titiya
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.804-806
    • /
    • 2003
  • Probable Maximum Precipitation (PMP) is essential in the design of hydraulic structures such as dams, weirs and flood control structures. Up to the present, PMP has been derived from any proper single storm which can have a large error. PMP values should be evaluated from many historic heavy storm events from all over the country. Since this can be done at the spots of storm occurring and the calculated PMP from all spots in the country can be correlated. The objectives of this study are therefore to evaluate PMP from historic heavy storm data from 1972 to 2000 by using meteorological method, then to correlate and to present the results using GIS. The maximized rainfall depths can be calculate from depth of heavy rainfall and dew point temperature, and then can be analyzed for each rainfall duration to obtain spatial rainfall distribution by using GIS. The depth-area-duration relationship of maximized rainfall can be obtained and this helps to develop enveloped curves . The results from this study are a set of contour maps of PMP for each rainfall duration for all over the country and the depth-area-duration relationships for the area of 100 to 50,000 km.$^{2}$ at duration of 1, 2 and 3 days.

  • PDF

공압기 소비전력에 대한 예측 모형의 비교연구 (A Comparison Study on Forecasting Models for Air Compressor Power Consumption)

  • 김주헌;장문수;김예진;허요섭;정현상;박소영
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.657-668
    • /
    • 2023
  • It's important to note that air compressors in the industrial sector are major energy consumers, accounting for a significant portion of total energy costs in manufacturing plants, ranging from 12% to 40%. To address this issue, researchers have compared forecasting models that can predict the power consumption of air compressors. The forecasting models were designed to incorporate variables such as flow rate, pressure, temperature, humidity, and dew point, utilizing statistical methods, machine learning, and deep learning techniques. The model performance was compared using measures such as RMSE, MAE and SMAPE. Out of the 21 models tested, the Elastic Net, a statistical method, proved to be the most effective in power comsumption forecasting.