• 제목/요약/키워드: temperature of degradation

검색결과 2,179건 처리시간 0.032초

고온부재의 재질열화에 따른 응력부식균열 평가에 관한 연구 (A Study on Stress Corrosion Cracking Evaluation with Material Degradation of High Temperature Components)

  • 박종진;유호선;정세희
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1123-1132
    • /
    • 1996
  • It has been reported that high temperature structural components represent the phenomenon of material degradation according to a long term service under high temperature and pressure. Especially, fossile power plant components using the fossil fuel and heavy oil are affected by dewpoint corrosion of $H_2SO_4$produced during a combustion. Therefore, the service materials subjected to high temperature and pressure may occur the stress corrosion cracking. The object of this paper is to investigate SCC susceptibility according to the material degradation of the high temperature structural materials in dewpoint corrosive environment-$H_2SO_4$.The obtained results are summarized as follows : 1) In case of secondary superheater tube, the fractograph of dimple is observed at the concentration of $H_2SO_4$-5%. When the concentration of $H_2SO_4$ is above 10%, the fracture mode is shifted from a transgranular fracture to an quasi-intergranular fracture according to the increment of concentration. 2) In the relationship between [$\Delta$DBTT]$_sp$ and SCC susceptibility, it is confirmed that the greater material degradation degree is, the higher SCC susceptibility is. In addition, it can be known that SP test is useful test method to evaluate SCC susceptibility for high temperature structural components. 3) When [$\Delta$DBTT]$_sp$ is above 17$17^{\circ}C$ the SCC fracture behavior is definitely observed with SCC susceptibility of above 0.4.

치과용 생체보철물 제작을 위한 TZP 단일구조 전부도재관 블럭의 물성과 저온열화 후 굴곡강도에 관한 연구 (The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry)

  • 이종화;박천만;송재상;임시덕;김재도;김병식;황인환;이성국
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.83-93
    • /
    • 2012
  • Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown. Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation, and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics. Results: The average density of the monolithic all-ceramic crown was $6.0280{\pm}0.0147g/cm$, the relative density was 99.01 %. When the sample was sintered at $1480^{\circ}C$ the diameter of average particle was $396.62{\pm}33.71nm$. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was $1747.40{\ss}{\acute{A}}$, at the temperature of $130^{\circ}C$ the flexural strength after the low temperature degradation was 1063.99MPa (p<0.001). There was statistically significant difference in the result of strength of 1020.07MPa after the low temperature degradation at the temperature of $200^{\circ}C$ (p<0.001). Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.

X-선 조사 후 고온 열화된 치자 염직물에서 추출한 색소 변이 연구 (A Study on Dye Variation Extracted from Dyed Textile with Gardenia degraded at HIgh temperature after X-ray Irradiation)

  • 윤다영;박혜진;박세은;허선홍;임수빈;정용재
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.53-61
    • /
    • 2024
  • This study explores the effects of X-ray irradiation for biological control and high-temperature degradation on dye stability in dyed textiles with Gardenia. To evaluate this study, optimal extraction solvents for these textiles were identified by comparing them with a crocin standard solution. Extraction using pyridine closely matched crocin. The study then assessed the stability of X-ray irradiation and high-temperature degradation on these textiles. Transparent yellow dyes were observed in all samples. Color differences were found to increase at higher irradiation doses and longer degradation periods. While UV spectroscopy spectra showed broadening and lowering trends with higher irradiation doses and longer degradation periods, suggesting a reduction in colorant transition, mass spectrometry revealed minimal chemical changes. In conclusion, both X-ray irradiation and high-temperature degradation induced spectral changes without complete dye decomposition. Major colorants were consistently detected.

디젤오염 지하수 정화를 위한 공기주입정화법 칼럼 실험 (Bio Sparging Column Experiment for Remediation of Diesel Contaminated Groundwater)

  • 장순웅;이시진;송정훈;권수열
    • 한국환경과학회지
    • /
    • 제13권12호
    • /
    • pp.1059-1065
    • /
    • 2004
  • Bio sparging experiments were conducted in a laboratory column to investigate the potential removal of diesel contaminated groundwater. The objectives in this study were (a) to determine the extent of diesel degradation in laboratory columns under supplement of nutrient; (b) to determine the effect of variation of air flow in the removal of diesel and (c) to evaluate the potential enhancement of diesel degradation as a function of temperature. Our results showed that the nutrient supplement and higher air flow greatly enhanced diesel degradation. However, the variation of water temperature examined slightly increased degradation rate of diesel fuel.

열화에 따른 파괴인성치의 연성-취성 천이거동 평가 (Evaluation of the Ductile-Brittle Transition Behavior of fracture Toughness by Material Degradation)

  • 석창성;김형익;김상필
    • 한국정밀공학회지
    • /
    • 제20권5호
    • /
    • pp.140-147
    • /
    • 2003
  • As the huge energy transfer systems like as nuclear power plant and steam power plant are operated for a long time at a high temperature, mechanical properties are changed and ductile-brittle transition temperature is raised by degradation. So it is required to estimate degradation in order to assess the safety, remaining life and further operation parameters. The sub-sized specimen test method using surveillance specimen was developed for evaluating the integrity of metallic components. In this study, we would like to present the evaluation technique of the ductile-brittle transition temperature by the sub-sized specimen test. The four classes of the thermally aged 1Cr-1Mo-0.25V specimens were prepared using an artificially accelerated aging method. The tensile test and fracture toughness test were performed. The results of the fracture toughness tests using the sub-sized specimens were compared with the evaluation technique of the ductile-brittle transition temperature.

적외선방사카메라를 이용한 트래킹열화 온도분포 (Temperature Distribution of Tracking Degradation Using IRR-Camera)

  • 정승천;임장섭;천종철;정우성;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Effect of Water Impingement Conditions on the Degradation of Epoxy Coatings in Tap Water

  • Kim, D.H.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.327-339
    • /
    • 2022
  • The water-jet technique started by Bridgman can cut metal and alloys without harmful gas and fume. However, while this technique is convenient to cut metals and alloys, in the case of coated pipe, water jet induces the degradation of coatings on the pipes, and may facilitate structural failure, leakage, and loss of products. While there are many reports on the effect of water jet on cut metals and the damage of metallic materials, research on the effect of water impingement on the epoxy coatings has been little studied. In this work, we therefore control the velocity of water jet, distance between nozzle and specimen, and water temperature, and discuss the effect of water impingement on the epoxy coatings. Increasing water velocity and water temperature and reducing nozzle distance increased the degradation rates of three epoxy coatings were increased. Among three test parameters - water velocity, nozzle distance and water temperature, water temperature was relatively effective to increase the degradation rate of epoxy coatings.

$^{18}O$을 함유하는 X-TZP의 저온열화거동 (Low Temperature Degradation Behavior of $^{18}O$-Containing Y-TZP)

  • 김병국
    • 한국세라믹학회지
    • /
    • 제34권2호
    • /
    • pp.171-174
    • /
    • 1997
  • 산소포논(phonon)이 Yttiria안정화 정방정 지르코니아 소결체(Yttria Stabilized Tetragonal Zirconia Po-lycrystals, Y-TZP)의 저온열화에 큰 영향을 미치는 사실을 실험적으로 밝혔다. Y-TZP의 저온열화 (정방정$\longrightarrow$단사정 상전이) 현상은 Y-TZP의 16O을 18O으로 치환함으로써 급격히 저하되었다. 이는 16O이 보다 무거운 18O으로 치환됨에 따라 임계변위 이상에서 산소원자가 존재할 확률이 감소하는 데 기인하는 것으로 설명하였다.

  • PDF

PEMFC 고분자 막의 전기화학적 열화에 미치는 온도의 영향 (Effect of Temperature on Electrochemical Degradation of Membrane in PEMFC)

  • 이호;김태희;손익제;이종현;임태원;박권필
    • Korean Chemical Engineering Research
    • /
    • 제47권4호
    • /
    • pp.441-445
    • /
    • 2009
  • 고분자전해질 막의 전기화학적 열화에 미치는 온도의 영향에 대해 연구하였다. 가속 열화 조건(OCV, anode 무가습, cathode 65% RH)에서 셀 온도를 변화시켜 144시간 운전한 후 셀 성능은 12에서 35%까지 감소하였다. 이러한 성능 감소는 FER(Fluoride Emission Rate) 측정에서 알 수 있듯이 과산화수소 혹은 산소라디칼(${\cdot}OH$, $HO_2{\cdot}$)의 공격에 의한 막의 열화에 따른 것으로 라디칼 형성을 위한 가스 crossover의 증가를 가져왔다. 전극에서의 라디칼 생성은 ESR로 확인하였다. 고분자막 열화의 온도 의존성을 나타내는 Arrhenius plot에 얻어진 활성화 에너지 값은 66.2 kJ/mol이었다. 셀 작동온도 증가는 라디칼 형성속도와 라디칼이 막을 공격하는 반응 속도뿐 아니라 가스 crossover 속도도 증가시켜 막 열화를 가속화시켰다.

혼합폐플라스틱 열분해 왁스오일의 고급화 연구 (A Study of Upgrading of Pyrolysis Wax Oil Obtained from Pyrolysis of Mixed Plastic Waste)

  • 이경환;남기윤;송광섭;김극태;최정길
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.321-324
    • /
    • 2009
  • Upgrading of pyrolysis wax oil has been conducted in a continuous fixed bed reactor at $450^{\circ}C$, 1hour, LHSV 3.5/h. The catalytic degradation using HZSM-5 catalyst are compared with the thermal degradation and also was studied with a function of experimental variables. The raw pyrolysis wax oil shows relatively high boiling point distribution ranging from around $300^{\circ}C$ to $550^{\circ}C$, which has considerably higher boiling point distribution than that of commercial diesel. The product characteristic from thermal degradation shows a similar trend with that of raw pyrolysis wax oil. This means the thermal degradation of pyrolysis wax oil at high degradation temperature is not sufficiently occurred. On the other hand, the catalytic degradation using HZSM-5 catalyst relative to the thermal degradation shows the high conversion of pyrolysis wax oil to light hydrocarbons. This liquid product shows high gasoline range fraction as around 90% fraction and considerably high aromatic fraction in liquid product. Also, in the catalytic degradation the experimental variable such as catalyst amount and reaction temperature was studied.

  • PDF