Non-Invasive in vivo Loss Tangent Imaging: Thermal Sensitivity Estimation at the Larmor Frequency

  • Choi, Narae;Kim, Min-Oh;Shin, Jaewook;Lee, Joonsung;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.36-43
    • /
    • 2016
  • Visualization of the tissue loss tangent property can provide distinct contrast and offer new information related to tissue electrical properties. A method for non-invasive imaging of the electrical loss tangent of tissue using magnetic resonance imaging (MRI) was demonstrated, and the effect of loss tangent was observed through simulations assuming a hyperthermia procedure. For measurement of tissue loss tangent, radiofrequency field maps ($B_1{^+}$ complex map) were acquired using a double-angle actual flip angle imaging MRI sequence. The conductivity and permittivity were estimated from the complex valued $B_1{^+}$ map using Helmholtz equations. Phantom and ex-vivo experiments were then performed. Electromagnetic simulations of hyperthermia were carried out for observation of temperature elevation with respect to loss tangent. Non-invasive imaging of tissue loss tangent via complex valued $B_1{^+}$ mapping using MRI was successfully conducted. Simulation results indicated that loss tangent is a dominant factor in temperature elevation in the high frequency range during hyperthermia. Knowledge of the tissue loss tangent value can be a useful marker for thermotherapy applications.

A Study on Changes in Local Meteorological Fields due to a Change in Land Use in the Lake Shihwa Region Using Synthetic Land Cover Data and High-Resolution Mesoscale Model (합성토지피복자료와 고해상도 중규모 모형을 이용한 시화호 지역의 토지이용 변화에 따른 주변 기상장 변화 연구)

  • Park, Seon Ki;Kim, Jee-Hee
    • Atmosphere
    • /
    • v.21 no.4
    • /
    • pp.405-414
    • /
    • 2011
  • In this study, the influence of a change in land use on the local weather fields is investigated around the Lake Shihwa area using synthetic land cover data and a high-resolution mesoscale model - the Weather Research and Forecasting (WRF). The default land cover data generally used in the WRF is based on the land use category of the United States Geological Survey (USGS), which erroneously presents most land areas of the Korean Peninsula as savannas. To revise such a fault, a multi-temporal land cover data, provided by the Ministry of Environment of Korea, was employed to generate a land cover map of 2005 subject to the land use in Korea at that time. A new land cover map of 1989, before the construction of the Lake Shihwa, was made based on the 2005 map and the Landsat 4-5 TM satellite images of two years. Over the areas where the land use had been changed (e.g., from sea to wetlands, towns, etc.) due to the Lake Shihwa development project, the skin temperature decreased by up to $8^{\circ}C$ in the winter case while increased by as much as $14^{\circ}C$ in the summer case. Changes in the water vapor mixing ratio were mostly affected by advection and topography in both seasons, with considerable increase in the summer case due to continuous sea breeze. Local decrease in water vapor occurred over high land use change areas and/or over downstream of such areas where alteration in wind fields were induced by changes in skin temperature and surface roughness at the areas of land use changes. The albedo increased by about 0.1% in the regions where sea was converted into wetland. In the regions where urban areas were developed, such as Songdo New Town and Incheon International Airport, the albedo increased by up to 0.16%.

Development of Map based Open Loop Control Algorithm for Urea - SCR System (Urea-SCR 시스템의 Map 기반 Open Loop 제어알고리즘 개발)

  • Ham, Yun-Young;Park, Yong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.50-56
    • /
    • 2011
  • To meet the NOx limit without a penalty of fuel consumption, Urea-SCR system is currently regarded as promising NOx reduction technology for diesel engines. SCR system has to achieve maximal NOx conversion in combination with minimal $NH_3$ slip. In this study, map based open loop control for urea injection was developed and assessed in the European Transient Cycle (ETC) for heavy duty diesel engine. The basic urea quantity set-value which was calculated using the look up tables of engine out NOx, exhaust flow rate and optimum NSR resulted in NOx reduction of 80% and the average $NH_3$ slip of 24 ppm and maximum of 79 ppm. In order to reduce $NH_3$ slip, $NH_3$ storage control algorithm was applied to correct the basic urea quantity and reduced $NH_3$ slip levels to the average 15 ppm and maximum 49 ppm while keeping NOx reduction of 76%. With high and increasing SCR temperature, the $NH_3$ storage capacity decreases, which leads to $NH_3$ slip. The resulting $NH_3$ slip peak can be avoided by stopping or significantly reducing the urea injection during the SCR temperature gradient is over $30^{\circ}C/min$.

Effect of Modified Atmosphere Packaging and Vacuum Packaging on Quality Characteristics of Low Grade Beef during Cold Storage

  • Hur, S.J.;Jin, S.K.;Park, J.H.;Jung, S.W.;Lyu, H.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.12
    • /
    • pp.1781-1789
    • /
    • 2013
  • Many studies have been carried out with respect to packaging methods and temperature conditions of beef. However, the effects of packaging methods and temperature conditions on the quality characteristics have not been extensively studied in low-grade beef. Low-grade beef samples were divided into 3 groups (C: ziplock bag packaging, T1: vacuum packaging, and T2: modified atmosphere packaging (MAP), $CO_2/N_2$ = 3:7) and samples were stored at $4^{\circ}C$ for 21 days. The water-holding capacity (WHC) was significantly lower in T1 than in the other samples up to 14 days of storage. The thiobarbituric acid reactive substances and volatile basic nitrogen values were significantly lower in T1 and T2 than in C after 7 to 14 days of storage. The total bacterial counts were significantly lower in T1 and T2 than in C after 14 days of storage. In a sensory evaluation, tenderness and overall acceptability were significantly higher in T1 and T2 than in C at the end of the storage period (21 days). We propose that the MAP method can improve beef quality characteristics of low-grade beef during cold storage. However, the beneficial effects did not outweigh the cost increase to implement MAP.

14 Planck Galactic Cold Clumps in the λ Orionis Complex: No dense cores detected with SCUBA-2

  • Yi, Hee-Weon;Lee, Jeong-Eun;Liu, Tie;Kim, Kee-Tae;Wu, Yuefang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.73.1-73.1
    • /
    • 2016
  • We present preliminary results of the submillimeter continuum observations of 14 Planck Galactic Cold Clumps (PGCCs), located in the ${\lambda}$ Orionis Complex. This region is the nearest large HII region, which is an ideal site for a study of the stellar feedback to its surroundings. We observed 14 PGCCs with JCMT/SCUBA-2 and used J=1-0 transitions of CO isotopologues from the PMO mapping observation. Several sub-clumps toward three PGCCs were detected at $850{\mu}m$. In order to examine whether these clumps can be candidates for pre-stellar cores, we compared each clump mass calculated from the $850{\mu}m$ continuum map to its Virial mass and Jeans mass calculated from the $^{12}CO$ and $C^{18}O$ (1-0) spectra, respectively. All clumps have masses smaller than their Virial and Jeans masses, indicating that none of them are gravitational bound and thus in the pre-stellar core stage. Also, the CO depletion factor, which has been derived from the dust continuum and the $C^{18}O$(1-0) line and can be an indicator of core evolution, toward the clumps is in the range of 1 to 5, suggesting that they are not very evolved dense pre-stellar cores. In addition, within individual PGCCs, we found clear gradients of velocity (${\sim}1km\;s^{-1}\;pc^{-1}$) and temperature (${\sim}10K\;pc^{-1}$) in the $^{13}CO$ (1-0) first moment map and the $^{12}CO$(1-0) excitation temperature map, respectively. This can be attributed to the compression and external heating by the HII region, which may prevent clumps from forming gravitationally bound structures and eventually disperse clumps. These results could be a hint about the negative effect of stellar feedback on core formation.

  • PDF

Computer Modeling of Modified Atmosphere Packaging of Peaches (복숭아의 환경기체조절포장을 위한 컴퓨터 모델링)

  • Kim, Jong-Kyoung;Ha, Young-Sun;Lee, Jun-Ho;Lee, Sang-Duk;Kim, Jae-Neung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.9 no.1
    • /
    • pp.33-54
    • /
    • 2003
  • The aim of this study was to develop a model that could be used in the design of modified atmosphere packaging (MAP) for peaches. Respiratory data at 5, 10, $20^{\circ}C$ for peaches were gathered and altered for create useful respiration model. Packaging materials were conventional low density polyethylene and polypropylene with anti-fog, and anti-fungi treatments, and thickness was $30{\mu}m$ and $50{\mu}m$ each. Permeability tests were performed to find their oxygen, carbon dioxide, water vapor transmission rate as increases in temperature. Test results were then converted to logarithm format for MAP modeling. The maximum rate of oxygen uptake increased with increasing temperature. Optimum gas composition in the package system for fruits were set according to literature and upper or lower limits of oxygen and dioxide established. To predict gas composition at certain storage time, weight of fruits, film thickness, film type, and other variables, respiration rate was studied at various storage conditions. The results of tests were used to calculate Cameron's model and converted to a cubic estimation equation. The validity of the model was tested experimentally by observing actual atmospheric changes inside packages. This result of study may be useful for designing dynamic gas exchange MAP systems for similar agricultural products.

  • PDF

Effect of initial ground temperature measurement on the design of borehole heat exchanger (초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향)

  • Song, Yoon-ho;Kim, Seong-Kyun;Lee, Kang-Kun;Lee, Tae-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests (화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구)

  • Choi, Keum-Ran
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.171-179
    • /
    • 2005
  • It is essential to understand the role of wall lining materials when they are exposed to a fire from an ignition source. Full-scale test methods permit an assessment of the performance of a wall lining material. Fire growth models have been developed due to the costly expense associated with full-scale testing. The models require heat flux maps from the ignition burner flame as input data. Work to date was impeded by a lack of detailed spatial characterization of the heat flux maps due to the use of limited instrumentation. To increase the power of fire modeling, accurate and detailed heat flux maps from the ignition burner are essential. High level spatial resolution for surface temperature can be provided from an infrared camera. The objective of this study was to develop a heat flux mapping procedure for a room test burner flame to a wall configuration with surface temperature information taken from an infrared camera. A prototype experiment was performed using the ISO 9705 test burner to demonstrate the developed heat flux mapping procedure. The results of the experiment allow the heat flux and spatial resolutions of the method to be determined and compared to the methods currently available.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

Comparison between Spatial Interpolation Methods of Temperature Data for Garlic Cultivation (마늘 재배적지분석을 위한 기온자료 공간보간기법 비교)

  • Kim, Yong-Wan;Hong, Suk-Young;Jang, Min-Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.5
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of this study is to decide a spatial interpolation method on temperature data for the suitability analysis of garlic cultivation. In Korea, garlic is the second most cultivated condiment vegetable after red pepper. Nowadays warm-temperate garlic faces potential shift of its arable area according to warmer temperature in the Korean Peninsula, and the change can be drawn with the precise temperature map derived from interpolation on point-measured data. To find the preferable interpolation method in cases of germination and vegetative period of the garlic, different approaches were tested as follows: Inverse Distance Weighted (IDW), Spline, Ordinary Kriging (OK), and Universal Kriging (UK). As a result, IDW and UK show the lowest root mean square errors as for the germination and vegetative seasons, respectively. However, statistically significant difference was not revealed among the applied methods regarding the germinating period. Eventually this will contribute to mapping the suitable lands for the cultivation of warm-temperate garlic reasonably.