• Title/Summary/Keyword: temperature limit

Search Result 1,360, Processing Time 0.023 seconds

A Study on The Pulsating Combustion of Premixed Gas in a Tube with a Honeycomb (다공성 물질에 의한 예혼합기의 맥동연소에 관한 연구)

  • 권영필;이동훈;현길학
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.676-684
    • /
    • 1990
  • This study is on the pulsating combustion of premixed gas in a Rijke type combustor made of a honeycomb flame holder in a tube. Modelling for the onset condition of the oscillation is made by the ratio of the acoustic power generation based on the analysis of heat transfer to the power loss due to the thermoviscous dissipation and radiation. Experiment is performed for the characteristics of acoustic, thermal and combustion. It is shown that the theoretical modelling for the oscillation may be used as a limit condition. And the combustion analysis for the acoustic power generation is needed for better prediction of the onset condition. Experimental result shows that, by pulsation, the flame length is shortened and the flame temperature is decreased with increase in the heat transfer coefficient. The NO$_{x}$ concentration in the exhaust gas is significantly reduced by pulsation and the concentration of unburned hydrocarbon shows a little increase.e.

Effect of Fe Doping on Thermoelectric Properties of Mechanically Alloyed $CoSb_3$

  • Ur, Soon-Chul;Kwon, Joon-Chul;Kim, Il-Ho
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.957-958
    • /
    • 2006
  • Fe doped skutterudite $CoSb_3$ with a nominal composition of $Fe_xCo_{1-x}Sb_{12}(0{\leq}x{\leq}2.5)$ have been synthesized by mechanical alloying (MA) of elemental powders, followed by vacuum hot pressing. Phase transformations during mechanical alloying and vacuum hot pressing were systematically investigated using XRD. Single phase skutterudite was successfully produced by vacuum hot pressing using as-milled powders without subsequent annealing. However, second phase of $FeSb_2$ was found to exist in case of $x\geq2$, suggesting the solubility limit of Fe with Co in this system. Thermoelectric properties as functions of temperature and Fe contents were evaluated for the hot pressed specimens. Fe doping up to x=1.5 with Co in $Fe_xCo_{4-x}Sb_{12}$ appeared to increase thermoelectric figure of merit (ZT) and the maximum ZT was found to be 0.78 at 525K in this study.

  • PDF

The Effects of Injector and Swirler on the Flame Stability in a Model Combustor (모델연소기에서의 분사기와 선회기의 영향)

  • Park, Seung-Hun;Lee, Dong-Hun;Bae, Chung-Sik
    • 한국연소학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.9-21
    • /
    • 1998
  • The optimization of frontal device including fuel nozzle and swirler is required to secure the mixing of fuel and air, and the combustion stability in the gas turbine combustor design for the reduction of pollutant emissions and the increase of combustion efficiency. The effects of injection nozzle and swirler on the flow field, spray characteristics and consequently the combustion stability, were experimentally investigated by measuring the velocity field, droplet sizes of fuel spray, lean combustion limit and the temperature field in the main combustion region. The effect of fuel injection nozzle was tested by adopting three different nozzles; a dual orifice fuel nozzle, a hollow cone nozzle and a solid cone nozzle. These tests were combined with the three different swirler geometries; a dual-stage swirler with 40$^{\circ}$ /-4 5$^{\circ}$ vanes and two single-stage swirlers with 40$^{\circ}$ vane angle having 12 and 16vanes, respectively. Flow fields and spray characteristics were measured with APV(Adaptive Phase Doppler Velocimetry) under atmospheric condition using kerosine fuel. Temperatures were measured by Pt-PtI3%Rh, R-type thermocouple which was 0.2mm thick. It was found that the dual swirler resulted in the biggest recirculation zone with the highest reverse flow velocity at the central region, which lead the most stable combustion. The various combustion characteristics were observed as a function of the combination between the injector and swirler, that gave a tip for the better design of gas turbine combustor.

  • PDF

Multi Analysis of Fumigants in Soil and Water (물과 토양에서 훈증제의 동시분석법 확립)

  • Kim, Jung-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.4 s.55
    • /
    • pp.365-373
    • /
    • 2006
  • Emission of methyl bromide (MeBr) from soil was implicated in stratospheric ozone depletion. To determine multi analysis of alternatives fumigants for MeBr, this paper describes the methods of analysis in water and soil. The MeBr, methyl iodide (Mel), propargyl bromide (PBr), cis 1,3-dichloropropene (cis 1,3-D), trans 1,3-dichloropropene (trans 1,3-D) and chloropicrin(CP) are separated on the base line on GC-ECD at three column of AT+DB+DB (90m) with temperature programing of $35^{\circ}C{\rightarrow}110^{\circ}C$ on GC-ECD. The relative retention time for MeBr, Mel, PBr, cis 1,3-D, trans 1,3-D and CP is 1.0, 1.4, 2.3, 3.2, 3.6 and 3.7, respertively. The detection limit for MeBr, Mel, PBr, cis 1,3-D, trans 1,3-D and CP is 469 pg, 5 pg, 21 pg, 79 pg, 101 PE and 5pg, respectively. Recovery of MeBr Mel, PBr, cis 1,3-D, trans 1,3-D and CP in water added 150 ppm fumigants were 81%, 96%, 95%, 97%, 98% and 99%, respectively. Recovery of MeBr, MeI, PBr, cis 1, 3-D, trans 1,3-D and CP in soil added 150ppm fumigants were 56%, 84%), 85%, 81%, 87% and 88%, respectively.

Teflon coating of fabric filters for enhancement of high temperature durability (섬유상 여과필터의 고온 내구성 향상을 위한 테프론 코팅 연구)

  • Kim, Eun-Joo;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.232-239
    • /
    • 2011
  • Fabric fibrous filter has been used in various industrial applications owing to the low cost and wide generality. However, the basic properties of fabric materials often limit the practical utilization including hot gas cleaning. This study attempts to find new coatings of porous fibrous filter media in order to overcome its insufficient thermal resistance and durability. Teflon was one of the plausible chemicals to supplement the vulnerability against frequent external thermal impacts. A foaming agent composed of Teflon and some organic additives was tentatively coated on the glass fiber mat. The present test Teflon foam coated filter was fount to be useful for hot gas cleaning, up to $250^{\circ}C$-$300^{\circ}C$. Close examination using XPS(X-ray Photoelectron Spectroscopy) and Contact angle proved the binding interactions between carbon and fluorine, which implies coating stability. The PTFE/Glass foam coated filter consisted of more than 95% (C-F)n bond, and showed super-hydrophobic with good-oleophobic characteristics. The contact angle of liquid droplets on the filter surface enabled to find the filter wet-ability against liquid water or oil.

Application of Organized Media for Rapid Spectrofluorimetric Determination of Trace Amounts of Cr(VI) in the Presence of Cr(III)

  • Madrakian, Tayyebeh;Afkhami, Abbas;Mohammadnejad, Masoumeh
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1252-1256
    • /
    • 2009
  • A simple, selective and sensitive fluorescence quenching method was developed to the determination Cr(VI). The method is based on the oxidation of $I^-\;to\;{{I_3}^-}$ by Cr(VI) in sulfuric acid solution followed by immediate formation of ion association compound between I3 − and rhodamine 6G in Tween-80 micellar media at room temperature. The influence of several surfactants on rhodamine 6G fluorescence signal was studied; particular attention was paid in the aggregation behavior of rhodamine 6G–Tween-80 system. The experimental parameters (e.g., type of surfactant, reagent concentration) were studied and the optimal conditions were established. The linear calibration graph was obtained in the range 2.0 - 100.0 ng m$L^{-1}$ Cr(VI). The detection limit of the method was 0.37 ng m$L^{-1}$. The relative standard deviation (R.S.D.) is less than 5% (n = 5). The efficiency of the method for the determination of Cr(VI) in the presence of Cr(III) in the sample was investigated. The method was applied successfully to the determination of Cr(VI) and total Cr in water, and liver tissue samples.

Ceramics Body Development Using Waste Whiteware (백자 파도자기를 활용한 도자기 소지 개발)

  • Lee, Jea-Il;Lee, Yong-Seok;Lee, Byung-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.10 s.293
    • /
    • pp.626-634
    • /
    • 2006
  • Ceramics manufacturers in the nation produced more than 5000 tons of ceramics wastes a year increasing industrial waste quantity: However, almost no researches were made to reduce environmental pollution and to recycle waste ware. In this study, white ware scraps that were produced at Icheon, Gyeonggi-do were recycled to make use of them as raw materials of ceramics body and to develop new ceramics body that had economic advantages and good quality. The findings showed that the addition of waste ware had limit of 20 wt% considering molding. The addition of waste ware of 20 wt% to white ware lowered baking temperature of the white ware that was added by waste ware of 20 wt% by 30$^{\circ}C$ than existing white ware, and property values were good, for instance, porosity of 3% in average and water absorptivity of 2% in average, and the bending strength recorded more than 800 kgf/$cm^2$ to be high than that of existing white ware being sold in market. The waste ware could be used to produce new ware body and to recycle resources and to solve environmental problems caused by burial and to improve property of ceramics and to save transportation costs as well as baking costs.

The Design, Fabrication, and Characteristic Experiment of Electromagnet to Control Element Drive Mechanism in System-Integrated Modular Advanced Reactor (일체형원자로 제어봉구동장치에 장착되는 전자석의 설계 및 특성해석)

  • Huh, Hyung;Kim, Jong-In;Kim, Kern-Jung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.4
    • /
    • pp.147-153
    • /
    • 2003
  • This paper describes the finite element analysis(FEA) for the design of electromagnet for Control Element Drive Mechanism(CEDM) in System-integrated Modular Advanced Reactor(SMART) and compared with the lifting power characteristics of prototype electromagnet. A thermal analysis was performed for the electromagnet. A model for the thermal analysis of the electromagnet was developed and theoretical bases for the model were established. It is important that the temperature of the electromagnet windings be maintained within the allowable limit of the insulation. since the electromagnet of CEDM is always supplied with current during the reactor operation. So the thermal analysis of the winding insulation which is composed of polyimide and air were performed by finite element method. As a result, it is shown that the characteristics of prototype electromagnet have a good agreement with the results of FEA. The thermal properties obtained here will be used as input for the optimization analysis of the electromagnet.

High Intensity Focused Ultrasound for Cancer Treatment: Current Agenda and the Latest Technology Trends (HIFU: 현황 및 기술적 동향)

  • Seo, Jong-Bum
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.2E
    • /
    • pp.55-63
    • /
    • 2010
  • High Intensity Focused Ultrasound (HIFU) is a noninvasive surgical method mainly targeting deeply located cancer tissue. Ultrasound is generated from an extemally located transducer and the beam is focused at the target volume, so that selective damage can be achieved without harm to overlying or surrounding tissues. The mechanism for cell killing can be combination of thermal and cavitational damage. Although cavitation can be an effective means of tissue destruction, the possibility of massive hemorrhage and the unpredictable nature of cavitational events prevent clinical application of cavitation. Hence, thermal damage has been a main focus related to HIFU research. 2D phased array transducer systems allow electronic scanning of focus, multi-foci, and anti-focus with multi-foci, so that HIFU becomes more applicable in clinical use. Currently, lack of noninvasive monitoring means of HIFU is the main factor to limit clinical applications, but development in MRI and Ultrasound Imaging techniques may be able to provide solutions to overcome this problem. With the development of advanced focusing algorithm and monitoring means, complete noninvasive surgery is expected to be implemented in the near future.

Lead(II)-selective Polymeric Electrode Using a Schiff Base Complex of N,N'-Bis-thiophene-2-ylmethylene-ethane-1,2-diamine as an Ion Carrier

  • Jeong, Tae-Jun;Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.8
    • /
    • pp.1219-1224
    • /
    • 2005
  • We prepared lead ion-selective PVC membranes that were based on N,N'-bis-thiophene-2-ylmethylene-ethane-1,2-diamine as a membrane carrier. The membrane electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-5}$ and 1.0 ${\times}$ $10^{-1}$ M with a Nernstian slope of 29.79 mV per decade, and its detection limit was 2.04 ${\times}$ $10^{-6}$ M at room temperature. The potentiometric response is independent of the pH of the solution in the pH range of 5-7. The proposed electrode revealed good selectivity and response for $Pb^{2+}$ over a wide variety of other metal ions in pH 5.0 buffer solutions, and there was good reproducibility of the base line on the subsequent measurements. The membrane electrode has a relatively fast response time, satisfactory reproducibility and a relatively long life time.