• 제목/요약/키워드: temperature distribution model

검색결과 1,488건 처리시간 0.032초

사이클론 집진장치의 내부 온도 변화에 따른 집진효율에 관한 전산해석적 연구 (Numerical Study on the Effect of the Internal Temperature Distribution in the Cyclone Dust Collector)

  • 현대근;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제10권4호
    • /
    • pp.155-162
    • /
    • 2014
  • The internal temperature will change depending on operation conditions and material of cyclone dust collector. This study compares the results of collection efficiency and temperature distribution on the different heat flux at wall of dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $600^{\circ}C$. Because of the difference of outer vortex and inner vortex temperature, the collection efficiency will reduce with the increase of heat flux, showed the highest collection efficiency at heat insulation.

Effects of decay heat and cooling condition on the reactor pool natural circulation under RVACS operation in a water 2-D slab model

  • Min Ho Lee ;Dong Wook Jerng ;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1821-1829
    • /
    • 2023
  • The temperature distribution of the reactor pool under natural circulation induced by the RVACS operation was experimentally studied. According to the Bo' based similarity law, which could reproduce the temperature distribution of the working fluid under natural circulation, SINCRO-2D facility was designed based on the PGSFR. It was reduced to 1 : 25 in length scale, having water as a simulant of the sodium, which is the original working fluid. In general, temperature was stratified, however, effect of the natural circulation flow could be observed by the entrainment of the stratified temperature. Relative cooling contribution of the upper plenum (narrow gap) and lower plenum was approximately 0.2 and 0.8, respectively. In the range of decay heat from 0.2% to 1.0%, only the magnitude of the temperature was changed, while the normalized temperature maintained. Boundary temperature distribution change made a global temperature offset of the pool, without a significant local change. Therefore, the decay heat and cooling boundary condition had no significant effect on temperature distribution characteristics of the pool within the given range of the decay heat and boundary temperature distribution.

GMA 용접공정에서 용접부의 표면 및 이면의 온도분포 (Temperature distribution of top and back surface in GMA welding process)

  • 김영선;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1408-1411
    • /
    • 1996
  • In arc welding processes, because of the complexity and nonlinearity of heat transfer phenomena, it is often difficult to design an effective control system based upon an exact mathematic model. In this paper, we simulated the welding process for various welding conditions and positions to investigate the variations of temperature distribution for those cases. Those will be used as a preinformation for developing quality control system for arc welding process.

  • PDF

강판의 유도가열에서 공정변수가 온도 및 자속분포에 미치는 영향에 관한 연구 (A Study of the Effects of Process Variables on Temperature and Magnetic-flux Distribution in Induction Heating of Steel Plate)

  • 배강열;이태환;양영수
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.526-533
    • /
    • 2001
  • Induction heating of float metal products has an increasing importance in many applications, because it generates the heat within workpiece itself and provides high power densities and productivity. In this study, the induction heating of a steel plate to simulate the line heating is investigated by means of the Finite Element Analysis of the magnetic field and temperature distribution. A numerical model is used to calculate temperature distribution within the steel plate during the induction heating with a specially designed inductor. The effects of materital properties depending on the temperature and magnetic field are taken into consideration in an iterative manner. The simulation results show good magnetic field with experimental data and provide good understanding of the process. Since the numerical model demonstrates to be suitable for analysis of induction heating process, the effects of air gap and frequency on magnetic-flux and power-density distribution are also investigated. It is revealed that these process parameters have an important roles on the electro-magnetic field and power-density distribution governing the temperature distribution of the plate.

  • PDF

온도기반의 Beta Distribution Model 을 이용한 후지 사과의 성숙기 예측 (Predicting Harvest Maturity of the 'Fuji' Apple using a Beta Distribution Phenology Model based on Temperature)

  • 최인태;심교문;김용석;정명표
    • 한국환경과학회지
    • /
    • 제26권11호
    • /
    • pp.1247-1253
    • /
    • 2017
  • The Fuji variety of apple, introduced in Japan, has excellent storage quality and good taste, such that it is the most commonly cultivated apple variety in Gunwi County, North Gyeongsang Province, Korean Peninsula. Accurate prediction of harvest maturity allows farmers to more efficiently manage their farm in important aspects such as working time, fruit storage, market shipment, and labor distribution. Temperature is one of the most important factors that determine plant growth, development, and yield. This paper reports on the beta distribution (function) model that can be used to simulate the the phenological response of plants to temperature. The beta function, commonly used as a skewed probability density in statistics, was introduced to estimate apple harvest maturity as a function of temperature in this study. The model parameters were daily maximum temperature, daily optimum temperature, and maximum growth rate. They were estimated from the input data of daily maximum and minimum temperature and apple harvest maturity. The difference in observed and predicted maturity day from 2009 to 2012, with optimal parameters, was from two days earlier to one day later.

신경회로망을 이용한 열성층 풍동내의 온도 분포 제어 (Control of temperature distribution in a thermal stratified tunnel by using neural networks)

  • 부광석;김경천
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.147-150
    • /
    • 1996
  • This paper describes controller design and implementation method for controlling the temperature distribution in a thermal stratified wind tunnel(TSWT) by using a neural network algorithm. It is impossible to derive a mathematical model of the relation between heat inputs and temperature outputs in the test section of the TSWT governed by a nonlinear turbulent flow. Thus inverse neural network models with a multi layer perceptron structure are used in a feedforward control loop and feedback control loop to generate an arbitrary temperature distribution in the test section of the TSWT.

  • PDF

자연환기시스템을 부착한 발코니의 열적 특성에 관한 연구 (The Study on Thermal Characteristic of the Balcony with Natural Ventilation System)

  • 조성우
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.347-354
    • /
    • 2005
  • This paper compared vertical temperature distribution between the existing balcony model without ventilator facilities and the improved balcony model with ventilator facilities using differential equation. As the air inside of balcony is heated by solar radiation this heated air is not exhausted in the existing balcony, remaining stagnant. The air temperature distribution was $26.7{\sim}29.3^{\circ}C$ in balcony without natural ventilator system. This heated air affected the rising air temperature of adjacent spaces such as living room and bedroom in the existing balcony. But, as the heated air inside of the improved balcony model is exhausted through natural ventilator facilities in summer, the air temperature in balcony has fallen. The air temperature distribution in improved balcony was $24.8{\sim}26.7^{\circ}C$ for the inlet air speed of 1 m/s and $24.6{\sim}26.7^{\circ}C$ for the inlet air speed of 3 m/s. The energy consumption of the improved balcony is 2.5 times less than of the existing balcony. The improved balcony with the closed damper makes a roll as the existing balcony in the aspect of the heating effect. When the heated air in the improved balcony is supplied, the air temperature is raised and the ventilation effect in adjacent spaces was improved.

Temperature analysis of a long-span suspension bridge based on a time-varying solar radiation model

  • Xia, Qi;Liu, Senlin;Zhang, Jian
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.23-35
    • /
    • 2020
  • It is important to take into account the thermal behavior in assessing the structural condition of bridges. An effective method of studying the temperature effect of long-span bridges is numerical simulation based on the solar radiation models. This study aims to develop a time-varying solar radiation model which can consider the real-time weather changes, such as a cloud cover. A statistical analysis of the long-term monitoring data is first performed, especially on the temperature data between the south and north anchors of the bridge, to confirm that temperature difference can be used to describe real-time weather changes. Second, a defect in the traditional solar radiation model is detected in the temperature field simulation, whereby the value of the turbidity coefficient tu is subjective and cannot be used to describe the weather changes in real-time. Therefore, a new solar radiation model with modified turbidity coefficient γ is first established on the temperature difference between the south and north anchors. Third, the temperature data of several days are selected for model validation, with the results showing that the simulated temperature distribution is in good agreement with the measured temperature, while the calculated results by the traditional model had minor errors because the turbidity coefficient tu is uncertainty. In addition, the vertical and transverse temperature gradient of a typical cross-section and the temperature distribution of the tower are also studied.

Stability analysis of an uncooled segment of superconductor

  • Seol, S.Y.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권3호
    • /
    • pp.8-12
    • /
    • 2017
  • If the part of the HTS magnet is exposed to the outside of the cryogenic coolant due to the fluctuation of the height of the cooling liquid or the vapor generation, the uncooled part becomes very unstable. In this paper, the unstable equilibrium temperature distribution of the uncooled part of a superconductor is obtained, and the maximum temperature and energy are calculated as a function of the uncooled length. Similar to the superconductor stability problem, the current sharing model was applied to derive the theoretical formula and calculated by numerical integration. We also applied a jump model, which assumes that joule heat is generated in all of the uncooled segment, and compares it with the current sharing model results. As a result of the analysis, the stable equilibrium state and the critical uncooled length in the jump model are not shown in the current sharing model. The stability of the conductors to external disturbances was discussed based on the obtained temperature distribution, maximum temperature, and energy.

엘리베이터 카 내부 기류분포에 관한 열 유동해석 (Thermal and Fluid Analysis on Air Distribution in a Elevator Car)

  • 정경택;이중섭
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.56-62
    • /
    • 2020
  • The purpose of this study is to observe the visualization of the flow field for air flow distributed in the car from the ventilation fan installed in the ceiling of the passenger elevator car through the numerical analysis using computational fluid dynamics. STAR-CCM+, which is a code used for the numerical analysis, was used to predict the airflow distribution inside the elevator car. The numerical analysis of the distribution of the air current in the elevator was carried out. As a result, the analysis results for each point and the visualization of the air current distribution and the temperature distribution in the elevator car and were obtained. It was found that heat transfer was actively occurring inside the car due to the influence of the flow field discharged from the ventilation vent installed in the ceiling in the elevator car, and especially the convection heat transfer of Model-2 was more active than that of Model-1. As a result, the temperature distribution inside the car was found to be relatively low. In addition, the temperature distribution at a cross-section of 1700mm height in the elevator car shows that Model-2 is the location of the ventilation vent which makes people feel more comfortable.