• Title/Summary/Keyword: temperature cycle

Search Result 2,574, Processing Time 0.029 seconds

Low Cycle Fatigue Behavior of Cobalt-Base Superalloy ECY768 at Elevated Temperature (코발트기 초내열합금 ECY768의 고온 저주기피로 거동)

  • Yang, Ho-Young;Kim, Jae-Hoon;Ha, Jae-Suk;Yoo, Keun-Bong;Lee, Gi-Chun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.18-22
    • /
    • 2013
  • The Co-base super heat resisting alloy ECY768 is employed in gas turbine because of its high temperature strength and oxidation resistance. The prediction of fatigue life for superalloy is important for improving the efficiency. In this paper, low cycle fatigue tests are performed as variables of total strain range and temperature. The relations between strain energy density and number of cycle to failure are examined in order to predict the low cycle fatigue life of ECY768 super alloy. The lives predicted by strain energy methods are found to coincide with experimental data and results obtained from the Coffin-Manson method. The fatigue lives is evaluated using predicted by Coffin-Manson method and strain energy methods is compared with the measured fatigue lives at different temperatures. The microstructure observing was performed for how affect able to low-cycle fatigue life by increasing the temperature.

Fatigue Crack Propagation Characteristics in SA 516-70 Steel for Pressure Vessels at Low Temperature (SA 516-70 압력용기용강의 저온피로 크랙전파 특성에 관한 연구)

  • Park, K.D.;Cha, S.S.
    • Journal of Power System Engineering
    • /
    • v.3 no.2
    • /
    • pp.51-56
    • /
    • 1999
  • Fatigue crack propagation rates and characteristics of the SA516-70 steel which is used for the low temperature pressure vessels, were studied in the room temperature of $10^{\circ}C$ and low temperature ranges of $-10^{\circ}C,\;-30^{\circ}C,\;-50^{\circ}C,\;and\;-70^{\circ}C$ with stress ratio of R=0.05. The obtained experimental results are as follows; 1) In the logarithmic relationship between the fatigue crack propagation rate(da/dN) and stress intensity factor K, the linear relationship was obtained up to da/dN > $8{\times}10^3$ mm/cycle in the same of room temperature, but in low temperature case, the relationship was extended to the range of low crack propagation rate. 2) The lower limit stress intensity factor of SA516-70 ${\Delta}K_{th}\;was\;23MPa\sqrt{m}$ and in the case of low temperature $-50^{\circ}C\;and\;-70^{\circ}C$, the crack propagation rate da/dN which showed a linear relation, reached rapidly to the ${\Delta}K_{th}$. As the results, the crack propagation rates of $-50^{\circ}C\;and\;-70^{\circ}C$ were lower than that of room temperature and according to the testing temperature the rates were decreased rapidly to the ${\Delta}K_{th}$. 3) On the relationship between the stress intensity factor ${\Delta}K$ and the track propagation cycle, the stress intensity factors of low cycle region was rapidly increased at low temperature, but ${\Delta}K$ was increased rapidly at room temperature of high cycle. 4) On the relationship between the fatigue crack propagation rate and cycle, the fatigue crack propagation rate showed higher gradient in the room temperature than the low temperature due to the increment in ductility at low temperature.

  • PDF

Fatigue Crack Propagation Characteristics in ASTM 516/60 Steel at Low Temperature (ASTM 516-60 강의 저온피로 크랙전파 특성에 관한 연구)

  • 박경동;김정호
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.240-245
    • /
    • 2000
  • Fatigue crack propagation rates and characteristics of the SA516-60 steel which is used for the low temperature pressure vessels, were studied in the room temperature of $25^{\circ}C$ and low temperature ranges of $10^{\circ}C,\; -10^{\circ}C,\; -30^{\circ}C,\; -50^{\circ}C, \;and\; -70^{\circ}C4 with stress ratio of R=0.05. The obtained experimental results are as follows; 1) In the logarithmic relationship between the fatigue crack propagation rate(da/dN) and stress intensity factor K, the linear relationship was obtained up to da/dN 〉$8\times10^{-3}$/mm/cycle in the same of room temperature, but in low temperature case, the relationship was extended to the range of crack propagation rate. 2) The lower limit stress intensity factor of SA516-60 $\DeltaK_{th}$ was 15.8MPa and in the case of low temperature $-50^{\circ}C\; and\; -70^{\circ}C$, the crack propagation rate da/dN which showed a linear relation, reached rapidly to the $\DeltaK_{th}$/. As the results, the crack propagation rates of $-50^{\circ}C\; and\; -70^{\circ}C$ were lower than that of room temperature and according to the testing temperature the rates were decreased rapidly to the $\DeltaK_{th}$/. 3) On the relationship between the stress intensity factor $\DeltaK$ and the crack propagation cycle, the stress intensity factors of low cycle region was rapidly increased at low temperature, but $\DeltaK$ was increased rapidly at room temperature of high cycle. 4) On the relationship between the fatigue crack propagation rate and cycle, the fatigue crack propagation rate showed higher gradient in the room temperature than the low temperature due to the increment in ductility at low temperature.

  • PDF

Mass flow rate ratio analysis for optimal refrigerant charge of a R744 and R404A cascade refrigeration system (R744-R404A 캐스케이드 냉동시스템의 최적 냉매 충전을 위한 질량유량비 분석)

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Jo, Hwan;Jeon, Min-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.575-581
    • /
    • 2013
  • In this paper, the influences of several factors, such as subcooling, superheating degree, internal heat exchanger efficiency, and etc. to the optimal amount of refrigerant charge are investigated for the case of R744-R404A cascade refrigeration system. Refrigerants used in the cascade refrigeration system are R404A in high temperature cycle and R744 in the low temperature cycle. The main results are summarized as follows : The mass flow rate ratio decreases with increasing subcooling, superheating degree and internal heat exchanger efficiency in the high temperature cycle, and evaporating temperature and compression efficiency in the low temperature cycle. And the mass flow rate ratio decreases with decreasing temperature difference of cascade heat exchanger and evaporating, condensing temperature in the high temperature cycle, and subcooling, superheating degree and internal heat exchanger efficiency in the low temperature cycle.

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.

Effect of simulated double cycle welding on HAZ microstructure for HSLA steels

  • El-Kashif, Emad F.;Morsy, Morsy A.
    • Advances in materials Research
    • /
    • v.7 no.3
    • /
    • pp.195-201
    • /
    • 2018
  • High Strength low alloy steels containing various levels of C, Nb and Mn were used and for each of which, a simulated double thermal cycle was applied with the same first peak temperature and different second peak temperatures to produce HAZ microstructure corresponding to multi-pass weld. Effect of double cycle second temperature on the microstructure was observed and compared with single cycle results obtained from previous works, it was found that the percentage of martensite austenite constituent (MA) increases by Nb addition for all steels with the same Mn content and the increase in Mn content at the same Nb content shows an increase in MA area fraction as well. MA area fraction obtained for the double cycle is larger than that obtained for the single cycle for all steels used which imply that MA will have great role in the brittle fracture initiation for double cycle and the inter-pass temperature should be controlled for medium and high-carbon Mn steel to avoid large area fraction of MA. The beneficial effects of Niobium obtained in single pass weld were not observed for the double cycle or multi pass welds.

An Example of Modification of Design Validation Test Specification to Reduce the Environmental Durability Test Time of Electronic Control Unit for Motor-Driven Power Steering system (전동식 조향 장치용 ECU 의 환경 내구 시험 시간 단축을 위한 설계 검증 시험 사양 변경 사례)

  • Kim, Tae-Hun;Kang, Dong-Young;Chung, In-Seung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1309-1313
    • /
    • 2008
  • This paper suggests an example of modification of the durability test specifications of electronic control unit for an automotive system in phase of design validation. The basic concept to redefine the specifications of durability test is based on the Arrhenius relationship for accelerated temperature test and the modified Coffin-Manson model for temperature cycle test. The ambient temperature of the powered-event durability test is increased to reduce the required test time of the current specification. Furthermore, the holding time between the events to cool down the temperature of the components is shortened and the resultant temperature rise affects the durability of the components. Thus, the acceleration factor due to the increased temperature range of temperature cycle is also estimated by the modified Coffin-Manson model.

  • PDF

Performance Characteristics of a Combined Regenerative Ammonia-Water Based Power Generation Cycle Using LNG Cold Energy (LNG 냉열을 이용하는 암모니아-물 복합 재생 동력 사이클의 성능 특성)

  • Kim, Kyounghoon;Oh, Jaehyeong;Jeong, Youngguan
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.6
    • /
    • pp.510-517
    • /
    • 2013
  • The ammonia-water based power generation cycle utilizing liquefied natural gas (LNG) as its heat sink has attracted much attention, since the ammonia-water cycle has many thermodynamic advantages in conversion of low-grade heat source in the form of sensible energy and LNG has a great cold energy. In this paper, we carry out thermodynamic performance analysis of a combined power generation cycle which is consisted of an ammonia-water regenerative Rankine cycle and LNG power generation cycle. LNG is able to condense the ammonia-water mixture at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the thermodynamic models, the effects of the key parameters such as source temperature, ammonia concentration and turbine inlet pressure on the characteristics of system are throughly investigated. The results show that the thermodynamic performance of the ammonia-water power generation cycle can be improved by the LNG cold energy and there exist an optimum ammonia concentration to reach the maximum system net work production.

Low Cycle Fatigue Characteristics of High Strength Low Alloy Steel (고강도 저합금강의 저주기 피로특성)

  • Kim, Jae-Hoon;Kim, Duck-Hoi;Lee, Jong-Hyun;Cho, Seong-Seock;Jeon, Byoung-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.169-174
    • /
    • 2001
  • Low cycle fatigue tests are performed on high strength low alloy steels that be developed for submarine material. The relation between absorbed plastic strain energy and numbers of cycle to failure is examined in order to predict the low cycle fatigue life of structural steels by using plastic strain energy method. The cyclic properties are determined by a least square fit techniques. The life predicted by the plastic strain energy method is found to coincide with experiment data and results obtained from the Coffin-Manson method. Also the cyclic behavior of structural steels is characterized by cyclic softening with increasing number of cycle at room temperature. Especially, low cycle fatigue characteristics and microstructural changes of structural steels are investigated according to changing tempering temperatures. In the case of PFS steels, the $\varepsilon$-Cu is formed in 550C of tempering temperature and enhances the low cycle fatigue properties.

  • PDF

Optimization Study on the Performance Analysis of Organic Rankine Cycle for Characteristics of Low Temperature Heat Sources (저온열원의 특성에 따른 ORC 성능해석 최적화 연구)

  • Eom, Hong-Sun;Yoon, Cheon-Seog;Kim, Young-Min;Shin, Dong-Gil;Kim, Chang-Gi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-60
    • /
    • 2012
  • Optimization procedures of performance analysis for ORC(Organic Rankine Cycle) system are established to the characteristics of low temperature heat sources such as open-type and closed-type. Effective heat recovery and heat extraction related to maximum power of the cycle as well as heat quality and thermal efficiency must be considered in the case of the open-type low temperature heat source. On the other hand, in the case of the closed-type low temperature heat source, only thermal efficiency is important due to constant heat input. In this study, thermal efficiency and exergy efficiency representing a level of close to Carnot cycle are studied, as useful index for the optimization of the ORC system. To validate the results of cycle analysis, those are compared with appropriate experimental data of ORC system as a thermal efficiency point of view.