• 제목/요약/키워드: temperature control feedback

검색결과 159건 처리시간 0.025초

Application of DFB Diode Laser Sensor to Reacting Flow (II) - Liquid-Gas 2-Phase Reacting Flow -

  • Park, Gyung-Min;Masashi Katsuki;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.139-145
    • /
    • 2003
  • Diode laser sensor is conducted to measure the gas temperature in the liquid-gas 2-phase counter flow flame. C$\_$10/H/ sub 22/ and city gas were used as liquid fuel and gas fuel, respectively. Two vibrational overtones of H$_2$O were selected and measurements were carried out in the spray flame region stabilized the above gaseous premixed flame. The path-averaged temperature measurement using diode laser absorption method succeeded in the liquid fuel combustion environment regardless of droplets of wide range diameter. The path-averaged temperature measured in the post flame of liquid-gas 2-phase counter flow flame showed qualitative reliable results. The successful demonstration of time series temperature measurement in the liquid-gas 2-phase counter flow flame gave us motivation of trying to establish the effective control system in practical combustion system. These results demonstrated the ability of real-time feedback from combustor inside using the non-intrusive measurement as well as the possibility of application to practical combustion system. Failure case due to influence of spray flame was also discussed.

신경망과 유동전류계를 이용한 정수장 응집제 주입제어에 관한 연구 (A Study on the Coagulant Dosing Control Based on Neural Network and Streaming Current Detector for Water Treatment Plant)

  • 김기평;김용열;유준;강이석
    • 제어로봇시스템학회논문지
    • /
    • 제10권6호
    • /
    • pp.551-556
    • /
    • 2004
  • Coagulation process is one of the most important processes in water treatment procedures for stable and economical operation, and coagulant dosing of this process for most plants is generally determined by the jar test. However, this method does not only take a long time to analyze and get the result but also has difficulties in applying to automatic control. This paper shows the feasibility of applying neural network to control the coagulant dosing automatically in water treatment plant. To be specific, the predicted results of the neural network model is shown to be similar to that of jar test. The input variables for learning the neural network are turbidity, water temperature, pH, and alkalinity. Combining the neural network and SCD(Streaming Current Detector) for feedforward and feedback control of injecting coagulant, a rapid change of the raw water quality can be accommodated.

Nuclear Design Feasibility of the Soluble Boron Free PWR Core

  • Kim, Jong-Chae;Kim, Myung-Hyun;Lee, Un-Chul;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.342-352
    • /
    • 1998
  • A nuclear design feasibility of soluble boron free(SBF core for the medium-sized(600MWe) PWR was investigated. The result conformed that soluble boron free operation could be performed by using current PWR proven technologies. Westinghouse advanced reactor, AP-600 was chosen as a design prototype. Design modification was applied for the assembly design with burnable poison and control rod absorber material. In order to control excess reactivity, large amount of gadolinia integral burnable poison rods were used and B4C was used as a control rod absorber material. For control of bottom shift axial power shape due to high temperature feedback in SBF core, axial zoning of burnable poison was applied to the fuel assemblies design. The combination of enrichment and rod number zoning for burnable poison could make an excess reactivity swing flat within around 1% and these also led effective control on axial power offset and peak pin power, The safety assessment of the designed core was peformed by the calculation of MTC, FTC and shutdown margin. MTC in designed SBF core was greater around 6 times than one of Ulchin unit 3&4. Utilization of enriched BIO(up to 50w1o) in B4C shutdown control rods provided enough shutdown margin as well as subcriticality at cold refueling condition.

  • PDF

ATWS Performance of KALIMER Uranium Metal Core

  • Dohee Hahn;Kim, Young C.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.592-597
    • /
    • 1996
  • The KALIMER core, of which nuclear design is largely governed by inherent safety and reactivity control issues, is fueled with metallic fuel, and the initial core will be loaded with 20% enriched Uranium metal fuel. KALIMER safety design objectives include the accommodation of unprotected, ATWS events without operator action, and without the support of active shutdown, shutdown heat removal, or any automatic system without damage to the plant and without jeopardizing public safety. The transient analysis of the core designs has been focused on severe events to assess the margins in the design, and ATWS events are the most severe events that must be accommodated by the KALIMER design. The ATWS performance has been evaluated for the preliminary initial core design of KALIMER with a particular emphasis on the inherent negative reactivity feedback effects, including the Doppler, sodium density, fuel axial expansion, core radial expansion, and control rod driveline expansion. Results show that the Uranium metal core design meets the temperature limits with margin.

  • PDF

OBSERVER-BASED INPUT-OUTPUT LINEARIZATION CONTROL OF A MULTIVARIABLE CONTINUOUS CHEMICAL REACTOR

  • Mohamed, Bouhamida;Bachir, Daaou;Abdellah, Mansouri;Mohammed, Chenafa
    • 대한수학회지
    • /
    • 제49권3호
    • /
    • pp.641-658
    • /
    • 2012
  • The goal of this paper is to develop a nonlinear observer-based control strategy for a multi-variables continuous stirred tank reactor (CSTR). A new robust nonlinear observer is constructed to estimate the whole process state variables. The observer is coupled with a nonlinear controller, designed based on the input-output linearization for controlling the concentration and reactor temperature. The closed loop system is shown to be globally asymptotically stable based on Lyapunov arguments. Finally, computer simulations are developed for showing the performance of the proposed controller.

저출력시 원전 증기발생기 수위제어 개선 연구 (A Study on Improvement of PWR Steam Generator Water Level Control at Low Power Operation)

  • Yun, Jae-Hee;Han, Jai-Bok;Joon Lyou
    • Nuclear Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.420-424
    • /
    • 1994
  • 가압경수로형 원자력발전소의 저출력 및 과도상태에서의 개선된 증기발생기 수위 제어 방식을 제시하였다. 수축 및 팽창 현상에 의한 수위의 요동을 줄이기 위해 기존의 비례·적분 제어기에 증기발생기 압력 및 급수온도를 고려한 앞먹임 보상부를 첨가하였다. 원전 훈련용 시뮬레이터를 이용하여 시뮬레이션을 수행한 결과 기존방식에 비해 적은 수위오차, 훨씬 빠른 진정시간을 얻을 수 있었다. 제시된 알고리즘은 구현이 용이하고 실제 적용도 가능하리라 판단된다.

  • PDF

Low Voltage CMOS LC VCO with Switched Self-Biasing

  • Min, Byung-Hun;Hyun, Seok-Bong;Yu, Hyun-Kyu
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.755-764
    • /
    • 2009
  • This paper presents a switched self-biasing and a tail current-shaping technique to suppress the 1/f noise from a tail current source in differential cross-coupled inductance-capacitance (LC) voltage-controlled oscillators (VCOs). The proposed LC VCO has an amplitude control characteristic due to the creation of negative feedback for the oscillation waveform amplitude. It is fabricated using a 0.13 ${\mu}m$ CMOS process. The measured phase noise is -117 dBc/Hz at a 1 MHz offset from a 4.85 GHz carrier frequency, while it draws 6.5 mA from a 0.6 V supply voltage. For frequency tuning, process variation, and temperature change, the amplitude change rate of the oscillation waveform in the proposed VCO is 2.1 to 3.2 times smaller than that of an existing VCO with a fixed bias. The measured amplitude change rate of the oscillation waveform for frequency tuning from 4.55 GHz to 5.04 GHz is 131 pV/Hz.

Regulated Incremental Conductance (r-INC) MPPT Algorithm for Photovoltaic Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1544-1553
    • /
    • 2019
  • The efficiency of photovoltaic generation systems depends on the maximum power point tracking (MPPT) technique. Among the various schemes presented in the literature, the incremental conductance (INC) method is one of the most frequently used due to its superb tracking ability under changes in insolation and temperature. Generally, conventional INC algorithms implement a simple duty-cycle updating rule that is mainly found on the polarity of the peak-power evaluation function. However, this fails to maximize the performance in both steady-state and transient conditions. In order to overcome this limitation, a novel regulated INC (r-INC) method is proposed in this paper. Like the compensators in automatic control systems, this method applies a digital compensator to evaluate the INC function and improve the capability of power tracking. Precise modeling of a new MPPT system is also presented in the optimized design process. A 120W boost peak power tracker is utilized to obtain comparative test results and to confirm the superiority of the proposed method over existing techniques.

초자왜소자의 자왜 특성의 측정 (Measurement of the Magnetostrictive Properties of Giant Magnetostrictive Alloy)

  • 백창욱;김용권
    • 한국자기학회지
    • /
    • 제4권4호
    • /
    • pp.303-306
    • /
    • 1994
  • 본 논문에서는 초자왜소자 $Terfenol-D(Tb_{0.3}Dy_{0.7}Fe_{1.9~1.95})$의 인가자장에 따른 자왜의 변화를 측정하였고, 잔류 자왜 및 초자왜소자의 온도 상승에 의한 열팽창 변형의 영향을 조사 하였다. 또한 초자왜소자에 3.5~14 MPa의 압축 응력을 인가하면서 자왜의 변화를 조사하였다. 그 결과는 인 가 압축 응력이 7 MPa인 경우 1500 Oe의 자장에서의 자왜는 1000 ppm이었으나 압축 응력을 가하지 않은 경 우는 400 ppm이었다. 또한 인가 압축 응력이 커짐에 따라서 자왜가 포화되는 자장의 크기도 커졌다. 잔류 변형과 히스테리시스가 관측되었으며, 따라서 액츄에이터로 이용할 때는 이를 보상하는 기구가 필요하며 또 한 열팽창에 의한 변형도 액츄에이터 응용시에는 고려하여야 한다.

  • PDF

Implementation of an in vitro exposure system for 28 GHz

  • Lee, Young Seung;Dzagbletey, Philip Ayiku;Chung, Jae-Young;Jeon, Sang Bong;Lee, Ae-Kyoung;Kim, Nam;Song, Seong Jong;Choi, Hyung-Do
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.837-845
    • /
    • 2020
  • The objective of this study was to implement an in vitro exposure system for 28 GHz to investigate the biological effects of fifth-generation (5G) communication. A signal source of 28 GHz for 5G millimeter-wave (MMW) deployment was developed, followed by a variable attenuator for antenna input power control. A power amplifier was also customized to ensure a maximum output power of 10 W for high-power 28-GHz exposure. A 3-dB uniformity over the 80 mm × 80 mm area that corresponds to four Petri dishes of three-dimensional cell cultures can be obtained using a customized choke-ring-type antenna. An infrared camera is employed for temperature regulation during exposure by adjusting the airflow cooling rate via real-time feedback to the incubator. The reported measurement results confirm that the input power control, uniformity, and temperature regulation for 28-GHz exposure were successfully accomplished, indicating the possibility of a wide application of the implemented in vitro exposure system in the fields of various MMW dose-response studies.