• 제목/요약/키워드: temperature characteristic

검색결과 2,914건 처리시간 0.03초

티타늄 합금판재(Ti-6Al-4V)의 고온 소성면형특성(1) (Plastic deformation characteristic of titanium alloy sheet (Ti-6Al-4V) at elevated temperature)

  • 박진기;김정한;박노광;김영석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.158-163
    • /
    • 2009
  • Titanium alloy sheets have excellent specific strength and corrosion resistance as well as good performance at high temperature. Recently, titanium alloys are widely employed not only aerospace parts but also bio prothesis and motorcycle. However, due to the low formability and large spring back at room temperature, titanium alloy sheets were usually formed by slow forming or hot forming with heating die and specimen. In the sheet metal forming area, FE simulation technique to optimize forming process is widely used. To achieve high accuracy FE simulation results, Identification of material properties and deformation characteristic such as yield function are very important. In this study, uniaxial tensile and biaxial tensile test of Ti-6Al-4V alloy sheet with thickness of 1.0mm were performed at elevated temperature of 873k. Biaxial tensile tests with cruciform specimen were performed until the specimen was breakdown to characterize the yield locus of Ti-6Al-4V alloy sheet. The experimental results for yield locus are compared with the theoretical predictions based on Von Mises, Hill, Logan-Hosford, and Balat's model. Among these Logan-Hosford's yield criterion well predicts the experimental results.

  • PDF

Fundamental characteristic analysis on 6 T-class high-temperature superconducting no-insulation magnet using turn-distributed equivalent circuit model

  • Liu, Q.;Choia, J.;Sim, K.;Kim, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.44-48
    • /
    • 2021
  • In order to obtain ultra-high resolution MRI images, research and development of 11 T or higher superconducting magnets have been actively conducted in the world, recently. The high-temperature superconductor (HTS), first discovered in 1986, was very limited in industrial application until mid-2010, despite its high critical current characteristics in the high magnetic field compared to the low-temperature superconductor. This is because HTS magnets were unable to operate stably due to the thermal damage when a quench occurred. With the introduction of no-insulation (NI) HTS magnet winding technology that does not burn electrically, it could be expected that the HTS magnets are dramatically reduced in weight, volume, and cost. In this paper, a 6 T-class NI HTS magnet for basic characteristic analysis was designed, and a distributed equivalent circuit model of the NI coils was configured to analyze the charging current characteristics caused by excitation current, and the charge delay phenomenon and loss were predicted through the development of a simulation model. Additionally, the critical current of the NI HTS magnets was estimated, considering the magnetic field, its angle and temperature with a given current. The loss due to charging delay characteristics was analyzed and the result was shown. It is meaningful to obtain detailed operation technology to secure a stable operation protocol for a 6T NI HTS magnet which is actually manufactured.

Condensation oscillation characteristic of steam with non-condensable gas through multi-hole sparger at low mass flux

  • Dandi Zhang;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.780-791
    • /
    • 2023
  • To study oscillation characteristic of steam and non-condensable gas direct contact condensation through multi-hole sparger at low mass flux, a series of experiments of pure steam and mixture gas condensation have been carried out under the conditions of steam mass flux of 20-120kg/m2s, water temperature of 20-95 ℃ and mass fraction of non-condensable gas of 0-5%. The regime map of pure steam condensation through multi-hole sparger is divided into steam chugging, separated bubble, aggregated bubble and escaping aggregated bubble. The bubbles behavior of synchronization in the same hole columns and desynchronized excitation between different hole columns can be found. The coalescence effect of mixture bubbles increases with water temperature and non-condensable gas content increasing. Pressure oscillation intensity of pure steam condensation first increases and then decreases with water temperature increasing, and increases with steam mass flux increasing. Pressure oscillation intensity of mixture gas condensation decreases with water temperature and non-condensable gas content increasing, which is significantly weaker than that of pure steam condensation. The oscillation dominant frequency decreases with the rise of water temperature and non-condensable gas content. The correlations for oscillation intensity and dominant frequency respectively are developed in pure steam and mixture gas condensation at low mass flux.

OPTIMUM PERFORMANCE AND DESIGN OF A RECTANGULAR FIN

  • Kang, H.S.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.705-711
    • /
    • 2007
  • A rectangular fin with a fluid in the inside wall is analyzed and optimized using a two-dimensional analytical method. The influence of the fluid convection characteristic number in the inside wall and the fin base thickness on the fin base temperature is listed. For the fixed fin volumes, the maximum heat loss and the corresponding optimum fin effectiveness and dimensions as a function of the fin base thickness, convection characteristic numbers ratio, convection characteristic number over the fin, fluid convection characteristic number in the inside wall, and the fin volume are represented. One of the results shows that both the optimum heat loss and the corresponding fin effectiveness increase as the fin base thickness decreases.

A study on a modeling method about current-voltage characteristic of HTS tape considering resistance of stabilizer

  • Lee, W.S.;Lee, J.;Nam, S.;Ko, T.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.9-12
    • /
    • 2013
  • Current-voltage characteristic models of superconducting material are suggested by many researchers. These current-voltage characteristic models are important because they can be used for design or simulation of superconductor devices. But widely used current-voltage models of superconductor wire still have some limitations. For example, a standard E-J power model has no parameters related with stabilizer's resistance in superconductor wire. In this paper, a current-voltage characteristic modeling method for high temperature superconductor (HTS) tape with considering the effect of stabilizer is introduced. And a current-voltage characteristic of a HTS tape is measured under different stabilizer conditions. Those measured current-voltage characteristics of the HTS tape modeled with proposed modeling method and the modeling results are compared.

시험 데이터를 지반으로 한 마이크로터빈 운전 시뮬레이션 (Operation Simulation of a Microturbine Based on Test Data)

  • 이종준;윤재은;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.22-28
    • /
    • 2006
  • Operation of a microturbine was simulated on the basis of component characteristic parameters obtained from performance test. Characteristic parameters, such as compressor and turbine efficiencies, recuperator effectiveness as well as turbine inlet temperature, were obtained for a wide operation range. Component characteristics including performance maps and characteristic curves were generated using measured data. Based on the component characteristics, a simulation program was constructed and operation of the microturbine was simulated, and the simulated results were compared with the measured data to verify the program. Also, influence of variation in the power control scheme on the operating characteristic and performance of the engine was simulated. The simulation program can be used for predicting operation of both healthy and degraded engine conditions.

고정된 핀 바닥 높이에 기준한 기하학적 비대칭 사다리꼴 핀의 최적 설계 (Optimum Design of a Geometrically Asymmetric Trapezoidal Fin Based on the Fixed Fin Base Height)

  • 강형석
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.81-87
    • /
    • 2008
  • A geometrically asymmetric trapezoidal fin with variable fin base thickness and height is optimized based on the fixed fin base height using a one-dimensional analytic method. The temperature profile along the normalized X position in the fin is presented. For the fixed fin base height, the optimum heat loss, fin length and efficiency as a function of inside fluid convection characteristic number, fin base thickness and height, fin shape factor, convection characteristic numbers ratio and ambient convection characteristic number are represented. One of the results shows that the effect of fin base height and ambient convection characteristic number on the optimum values is remarkable.

Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

  • Jung, Dong Kyung;Kim, Sung Kyu;Lee, Joon Ha;Youn, Sang Mo;Kim, Hyung Dong;Oh, Se An;Park, Jae Won;Yea, Ji Won
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.224-231
    • /
    • 2016
  • The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with that of the Gel Bolus phantom under conditions similar to those of an agar phantom that can continuously carry out temperature measurement. The temperatures of the agar phantom and the Gel Bolus phantom were raised to $36.5{\pm}3^{\circ}C$ and a temperature sensing was inserted at depths of 5, 10, and 15 cm from the phantom central axis. The temperature increase rate and the coefficient of determination were analyzed while applying output powers of 100 W and 150 W, respectively, at intervals of 1 min for 60 min under conditions where the indoor temperature was in the range $24.5{\sim}27.5^{\circ}C$, humidity was 35~40%, internal cooling temperature of the electrode was $20^{\circ}C$, size of the upper electrode was 250 mm, and the size of the lower electrode was 250 mm. The coefficients of determination of 150 W output power at the depth point of 5 cm from the central axis of the phantom were analyzed to be 0.9946 and 0.9926 in the agar and Gel Bolus phantoms, respectively; moreover, the temperature change equation of the agar and Gel Bolus phantoms with time can be expressed as follows in the state the phantom temperature is raised to $36^{\circ}C:Y(G)$ is equation of Gel Bolus phantoms (in 5 cm depth) applying output power of 150 W. Y(G)=0.157X+36. It can be seen that if the temperature is measured in this case, the Gel Bolus phantom value can be converted to the measured value of the agar phantom. As a result of comparing the temperature distribution characteristics of the agar phantom of a human-body-equivalent material with those of the Gel Bolus phantom that can be continuously used, the usefulness of Gel Bolus phantom was exhibited.

폴리론 화이버 공법의 현장적용을 위한 Mock-up Test (Mock-up Test for Field Application of a Polylon Fiber Method)

  • 권해원;손호정;지석원;이병훈;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.405-408
    • /
    • 2008
  • 본 연구는 폴리론 화이버 공법의 현장 적용을 위한 Mock-up 실험으로, 폴리론 화이버 0.05% 혼입한 고강도 콘크리트의 기초적 특성 및 내화특성에 대해 분석하였는데, 그 결과를 요약하면 다음과 같다. 굳지않은 콘크리트의 특성으로, 슬럼프플로우 및 공기량은 모두 목표 범위를 만족하는 것으로 나타났고, 경화 콘크리트의 특성으로 양생 조건에 따른 압축강도는 모두 설계기준강도 60 MPa 만족하는 것으로 나타났다. 내화특성으로, 시험체의 표면부에 일부 약간의 박리 폭렬 현상이 나타났지만, 전체적으로는 양호한 내화성능을 나타내었다. 온도이력 특성으로, 3시간 내화시험 후 주근부 최고온도 $531{\circ}C$, 평균온도 $405{\circ}C$로 국토해양부의 내화기준을 만족하였다.

  • PDF

분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석 (Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board)

  • 문현욱;김동우;길형준;김동욱;이기연;김향곤
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.100-106
    • /
    • 2009
  • 본 논문에서는 전기설비의 전기적 접속부 또는 전기배선 등에서 발생하는 이상발열을 감지하는 방법에 대해 알아보고, 분전함에서의 발열상태를 실시간으로 모니터링하는 전력설비 진단시스템에 사용되고 있는 광온도센서에 대하여 동작특성을 실험, 분석하였다. 광온도센서의 동작특성 실험을 위한 열원으로는 Black Body와 Hot Plate를 사용하였으며 각각에서의 열원의 온도변화에 따른 광온도센서 출력전압값을 측정, 분석하였다. 그리고 분전함내 차단기 단자에서의 체결불량으로 인한 이상발열 감지 실험을 기존의 발열 감지방법인 열전대와 적외선 열화상장치를 이용하여 실시하였고, 광온도센서를 이용해 실시하여 결과를 비교 분석하였다. 실험결과, 광온도센서의 이상발열 감지능력이 유사함을 확인할 수 있었다. 이러한 분석 결과는 향후 RFID형 광온도센서를 이용한 전력설비 진단시스템의 현장 적용에 있어 기본 자료가 될 것으로 기대된다.