• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.024 seconds

The Effects of Indigotin and Indirubin Pigments on the Dyeability and the Color of Silk Dyed with Indigo and Indirubin Mixed Dye (인디고 및 인디루빈 표준 혼합염료에서 인디고틴과 인디루빈 색소가 견직물에 대한 염착성과 색상에 미치는 영향 연구)

  • Yoo, Wansong;Ahn, Cheunsoon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.914-928
    • /
    • 2017
  • This research investigated the effect of pH of dyebath and dyeing temperature on the dyeability of indigotin and indirubin on silk as well as the relationship between the amount of indigotin and indirubin detected from the dyed silk through HPLC-DAD analysis and the color of samples measured using a spectro-colorimeter. Indigo standard dye and indirubin standard dye were deliberately mixed by ratios 100:0, 80:20, 60:40, 40:60, 20:80, and 0:100 to dye silk with a different pH of dyebath (7, 11) and different dyeing temperatures ($50^{\circ}C$, $70^{\circ}C$). The amount of indigotin and indirubin pigments in silk was calculated using regression equations obtained from standard calibration curves of indigotin and indirubin. A higher indigotin percent ratio resulted in the higher K/S values and the higher amount of indigotin detected from silk. However, higher indirubin percent ratio in the mixed dye did not relate to the higher indirubin pigment detected in silk. While indirubin showed low or negative contribution to the K/S values, it showed a higher effect on the color of dyed silk. Higher amounts of indirubin in dyed silk resulted in a darker PB color, which led to P color with increases in indirubin content.

Bioavailability of Tripotassium Dicitrato Bismuthate by ICP-MS in Human Volunteers (ICP-MS를 사용한 구연산비스마스칼륨 (Tripotassium dicitrato bismuthate)의 생체이용률 측정)

  • Kwon, Oh-Seung;Kwon, Jee-Young;Yoon, Ae-Rin;Park, Kyung-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.2
    • /
    • pp.79-84
    • /
    • 2007
  • This study was aimed to establish analytical method of Bi to develop a guideline of the bioequivalence test of tripotassium dicitrato bismuthate (TDB). For this purpose, a simple, specific and sensitive inductively coupled plasma-mass spectrometry (ICP/MS) method were developed and validated in human plasma. Various concentrations of bismuth standard solution (0-25ng/mL) were prepared with distilled water and human blank plasma. To 10mL of the volumetric flasks, 2mL of blank plasma was added with 8ml of distilled water. Bi standard solution was added to prepare the calibration samples and injected into ICP-MS. The plasma samples obtained from volunteers given 3 tablets of bismuth (total 900mg as TDB) were analyzed as described above. As a result, the coefficients of variation were <20% in quantitation limit (0.2 ng/mL) and <15% at the rest of concentrations. The stability test by repeated freezing-thawing cycles showed that the samples were stable only for 24hr. The stability tested for samples with a short-term period of storage at room temperature and pre-treatment prior to the analysis showed very stable over 24hr. In 8 healthy Korean subjects received Denol tablets at the dose of 900mg bismuth, AUC, $C_{max},\;T_{max}$ and half-life $(t_{1/2})$ were determined to be $198.33{\pm}173.78 ng{\cdot}hr/mL,\;64.48{\pm}27.06 ng/mL,\;0.52{\pm}0.21 hr,\;and\;5.15{\pm}2.67 hr$, respectively, from the plasma bismuth concentration-time curves. In conclusion, the method was suitable for the determination of bismuth in human plasma samples and could be applied to bioequivalence test of bismuth tablet.

Prediction of Water Quality in Haenam Estuary Reservoir Using Multiple Box Model (I) -Development and Application of Water Quality Subroutines- (Multiple Box 수질모형에 의한 해남호 수질예측 (I) - 수질부 모형의 개발과 적용 -)

  • 신승수;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.3
    • /
    • pp.116-129
    • /
    • 1990
  • A rational management of water resources in estuary reservoirs necessiates the prediction of water quality. In this study, a multiple box model for the water quality prediction was developed as a tool for the purpose of examining an adequate way to improve and maintain the water quality. Some submodels that are suitable for simulating the mixing behavior of pollutant materials in a lake were considered in this model. The model was appiled for predicting water qualities of Haenam Esturay Reservoir. The result from this study can be summarized as follows : 1.A water quality simulation model that can predict the 10-day mean value of water qualities was developed by adding some submodels that simulate the concentrations of chlorophyll-a, BOD, T-P and T-N to the existing Multiple Box Model representing the mixing and circulating of materials by the hydarulic action. 2.As input data for the model developed, the climatic data including precipitation, solar radiation, temperature, cloudness, wind speed and relative humidity, and the water buget records including the pumping discharge and the releasing discharge by drainage gate were ollected. The hydrologic data for the inflow discharge from the watershed was obtained by simulation with the aid of USDAUL-74/SNUA watershed model. Also the water quality data were measured at streams and the reservoir. 3.As a result of calibration and verification test by using four comonents of water quality such as Chlorophyll-a, BOD, T-P and T-N, it was found that the correlation coefficeints between the observed and the simulated water qualities showed greater than 0.6, therefore the capability of the model to simulate the water quality was proved. 4.The result based on the model application showed that the water quality of the Haenam Estuary Reservoir varies seasonally with the harmonic trend, however the water quality is good in winter and get worse in summer. Also it may be concluded that the current grarde of water quality in the Heanam Esutary Reservoir is ranked as grade 4 suitable only for the agricultutal use.

  • PDF

Measurement and Analysis of Free Water Evaporation at HaeNam Paddy Field (해남 농경지에서의 자유 수면 증발 관측과 해석)

  • Han Jin-Su;Lee Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.91-97
    • /
    • 2005
  • Class A evaporation pan has been used throughout the world to measure free water evaporation mainly by manual observation once a day. In this study, a new automatic water level measurement method is used for understanding of free water evaporation and numerical analysis. This new technique measures the weight of buoyancy bar in water, and does not need calibration because it is not affected by water density change with water temperature. Field observations of evaporation were made near Haenam Meteorological Station over paddy field located in southwestern Korea from 20 April to 30 May 2004 and the data from ten clear days (16 - 25 May) were used for this analysis. The observed total evaporation was about 50.7mm during this period whereas the estimated from an empirical equation was 50.4mm. As expected, the pan evaporation is well correlated with wind speed and the vapor pressure deficit between the water surface and the air.

Climate and Land use Changes Impacts on Hydrology in a Rural Small Watershed (장래 기후변화와 토지이용 변화에 따른 농촌소유역의 수문 영향 분석)

  • Kim, Hak-Kwan;Kang, Moon-Seong;Lee, Eun-Jeong;Park, Seung-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.75-84
    • /
    • 2011
  • The objective of this study is to evaluate the hydrologic impacts of climate and land use changes in a rural small watershed. HadCM3 (Hadley Centre Coupled Model, ver.3) A2 scenario and LARS-WG (Long Ashton Research Station - Weather Generator) were used to generate future climatic data. Future land use data were also generated by the CA-Markov (Cellular Automata-Markov) method. The Soil and Water Assessment Tool (SWAT) model was used to evaluate hydrologic impacts. The SWAT model was calibrated and validated with stream flow measured at the Baran watershed in Korea. The SWAT model simulation results agreed well with observed values during the calibration and validation periods. In this study, hydrologic impacts were analyzed according to three scenarios: future climate change (Scenario I), future land use change (Scenario II), and both future climate and land use changes (Scenario III). For Scenario I, the comparison results between a 30-year baseline period (1997~2004) and a future 30-year period (2011~2040) indicated that the total runoff, surface runoff, lateral subsurface runoff, groundwater discharge, and evapotranspiration increased as precipitation and temperature for the future 30-year period increased. The monthly variation analysis results showed that the monthly runoff for all months except September increased compared to the baseline period. For Scenario II, both the total and surface runoff increased as the built-up area, including the impervious surface, increased, while the groundwater discharge and evapotranspiration decreased. The monthly variation analysis results indicated that the total runoff increased in the summer season, when the precipitation was concentrated. In Scenario III, the results showed a similar trend to that of Scenario II. The monthly runoff for all months except October increased compared to the baseline period.

Simultaneous Determination of Liquiritin, Nodakenin, Hesperidin and Glycyrrhizin in Bojungikgi-tang Using HPLC-PDA (HPLC-PDA를 이용한 보중익기탕 중 Liquiritin, Nodakenin, Hesperidin 및 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.57 no.3
    • /
    • pp.187-193
    • /
    • 2013
  • Bojungikgi-tang has been widely used for enhancement of physical fitness in Korea. The convenient, simple, and accurate high-performance liquid chromatography (HPLC) method was established for simultaneous determination of four marker compounds, liquiritin, nodakenin, hesperidin, and glycyrrhizin in Bojungikgi-tang (Buzhongyiqi-tang in Chinese, Hochuekkito in Japanese), a traditional Korean herbal prescription. The column for optimizing HPLC separation was used a Gemini $C_{18}$ column at column oven temperature of $40^{\circ}C$ with 1.0% (v/v) aqueous acetic acid (A) and 1.0% (v/v) acetic acid in acetonitirle (B) by gradient flow. The flow rate was 1.0 ml/min and the detector was a photodiode array (PDA) set at 254 nm, 280 nm, and 335 nm. Calibration curves of four components were acquired with $r^2$ values ${\geq}0.9999$. The recoveries were found to range 92.11~105.68% with relative standard deviations (RSDs, %) value less than 2.50%. The RSD values of intraand inter-day precision were 0.07~2.50% and 0.16~1.99%, respectively. The contents of liquiritin, nodakenin, hesperidin and glycyrrhizin in Bojungikgi-tang were 3.85~3.92 mg/g, 2.27~2.32 mg/g, 4.14~4.19 mg/g, and 3.39~3.45 mg/g, respectively. The established simultaneous analysis method will be effective for quality control of Bojungikgi-tang.

An analysis of Electro-Optical Camera (EOC) on KOMPSAT-1 during mission life of 3 years

  • Baek Hyun-Chul;Yong Sang-Soon;Kim Eun-Kyou;Youn Heong-Sik;Choi Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.512-514
    • /
    • 2004
  • The Electro-Optical Camera (EOC) is a high spatial resolution, visible imaging sensor which collects visible image data of the earth's sunlit surface and is the primary payload on KOMPSAT-l. The purpose of the EOC payload is to provide high resolution visible imagery data to support cartography of the Korean Peninsula. The EOC is a push broom-scanned sensor which incorporates a single nadir looking telescope. At the nominal altitude of 685Km with the spacecraft in a nadir pointing attitude, the EOC collects data with a ground sample distance of approximately 6.6 meters and a swath width of around 17Km. The EOC is designed to operate with a duty cycle of up to 2 minutes (contiguous) per orbit over the mission lifetime of 3 years with the functions of programmable gain/offset. The EOC has no pointing mechanism of its own. EOC pointing is accomplished by right and left rolling of the spacecraft, as needed. Under nominal operating conditions, the spacecraft can be rolled to an angle in the range from +/- 15 to 30 degrees to support the collection of stereo data. In this paper, the status of EOC such as temperature, dark calibration, cover operation and thermal control is checked and analyzed by continuously monitored state of health (SOH) data and image data during the mission life of 3 years. The aliveness of EOC and operation continuation beyond mission life is confirmed by the results of the analysis.

  • PDF

Effect of critical flow model in MARS-KS code on uncertainty quantification of large break Loss of coolant accident (LBLOCA)

  • Lee, Ilsuk;Oh, Deogyeon;Bang, Youngseog;Kim, Yongchan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.755-763
    • /
    • 2020
  • The critical flow phenomenon has been studied because of its significant effect for design basis accidents in nuclear power plants. Transition points from thermal non-equilibrium to equilibrium are different according to the geometric effect on the critical flow. This study evaluates the uncertainty parameters of the critical flow model for analysis of DBA (Design Basis Accident) with the MARS-KS (Multi-dimensional Analysis for Reactor Safety-KINS Standard) code used as an independent regulatory assessment. The uncertainty of the critical flow model is represented by three parameters including the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio, and their ranges are determined using large-scale Marviken test data. The uncertainty range of the thermal non-equilibrium factor is updated by the MCDA (Model Calibration through Data Assimilation) method. The updated uncertainty range is confirmed using an LBLOCA (Large Break Loss of Coolant Accident) experiment in the LOFT (Loss of Fluid Test) facility. The uncertainty ranges are also used to calculate an LBLOCA of the APR (Advanced Power Reactor) 1400 NPP (Nuclear Power Plants), focusing on the effect of the PCT (Peak Cladding Temperature). The results reveal that break flow is strongly dependent on the degree of the thermal non-equilibrium state in a ruptured pipe with a small L/D ratio. Moreover, this study provides the method to handle the thermal non-equilibrium factor, discharge coefficient, and length to diameter (L/D) ratio in the system code.

USN-based Water Treatment Plant Facilities Data Management Techniques and Reliability (USN 기반 수직형 정수처리시설 데이터 최적관리 및 신뢰성 검증연구)

  • Jang, Sang-Bok;Shin, Gang-Wook;Hong, Sung-Taek;Lee, An-Kyu;Park, Hye-Mi;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2736-2744
    • /
    • 2013
  • In this paper, we present a Smart Water Treatment Plant using Zigbee USN devices and a real-time monitoring system in K-water Flow Meter Calibration Center Building. For verification, the data of vertical type WTP such as flow rate, pressure, water level and water temperature are obtained by the Zigbee USN devices, operating in 2.45 GHz band, and be wirelessly surveilled by the real-time monitoring system. The received data from the sensor is transmitted to the data processing device, and then the processed data can be monitored on a smart phone. Consequently, the pilot plant based on the low-cost and high-efficiency USN has been developed with the performance analysis for the communication network and remote monitoring system on mobile devices.

CHARACTERISTICS OF THE FAIRCHILD 486 CCD AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKISTAN (우즈베키스탄 Maidanak 천문대 Fairchild 486 CCD의 기본적인 특성)

  • Lim, Beom-Du;Sung, Hwan-Kyung;Karimov, R.;Ibrahimov, M.
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Understanding of the basic characteristics of an astronomical instrument is a prerequisite to obtaining reliable data from the instrument. We have analyzed more than 1,000 calibration images from the Fairchild 486 CCD (hereafter the Maidanak 4k CCD system) attached to the AZT-22 1.5m telescope at Maidanak Astronomical Observatory in Uzbekistan. The Maidanak 4k CCD system supports three readout modes through 1, 2, or 4 amplifiers. In most cases observers use 4-amplifier readout mode to save time. We have tested the stability and seasonal variation of zero levels and confirm that two quadrants of the images (Amp 1 & 2) show no appreciable seasonal variation. but the other two quadrants (Amp 3 & Amp 4) show an evident seasonal variation in the bias level. The Cryo Tiger, the cooling system used at the Maidanak 4k CCD system, maintains the CCD temperature at -108'E, and effectively suppresses the dark electrons. The mean value versus the variance plot of the flat images does not show the expected relation for an ideal Poisson noise distribution and this is attributed to the large variation in quantum efficiency between different pixels. In addition, we confirm that there is no appreciable difference in gain between readout amplifiers, but there is a large variation in quantum efficiency across CCD chip especially in U. Due to the finite length of shutter opening and closing time, the effective exposure time varies across the science images. We introduce two parameters to quantify the effect of this uneven illumination and present a method to remove these effects. We also present a method to remove the interference patterns appearing in the images obtained with longer wavelength filters and investigate the spatial variation of the point spread function.