• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.021 seconds

RESULTS OF THE TOTAL DOSE EXPERIMENT ON KITSAT-1 (우리별 1호에서의 총 방사선 측정 실험)

  • 이대희;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.80-86
    • /
    • 1997
  • High energy particles in the earth's radiation belts cause transient and long term effects on electronic materials, devices, and integrated circuits on board the satellites. Hence, it is very important to have the information on the space radiation environment and the damage on the electronics caused by the se high energy particles. One of the radiation monitor devices frequently used in space is RADFET, a specially designed MOSFET with a thick gate oxide region. The present study focuses on the calibration of RADFET TOT500 using the $Co^{60}{\gamma}-ray$ source. The result shows that the response of RADFET is very sensitive to the change of temperature. The peculiar behavior observed in the TDE (Total Dose Experiment) on board the KITSAT-1 is identified as the thermal effect due to the change in the eclipse rate of the satellite.

  • PDF

Localization Algorithm for a Mobile Robot using iGS (iGS를 이용한 모바일 로봇의 실내위치추정 알고리즘)

  • Seo, Dae-Geun;Cho, Sung-Ho;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.3
    • /
    • pp.242-247
    • /
    • 2008
  • As an absolute positioning system, iGS is designed based on ultrasonic signals whose speed can be formulated clearly in terms of time and room temperature, which is utilized for a mobile robot localization. The iGS is composed of an RFID receiver and an ultra-sonic transmitter, where an RFID is designated to synchronize the transmitter and receiver of the ultrasonic signal. The traveling time of the ultrasonic signal has been used to calculate the distance between the iGS system and a beacon which is located at a pre-determined location. This paper suggests an effective operation method of iGS to estimate position of the mobile robot working in unstructured environment. To expand recognition range and to improve accuracy of the system, two strategies are proposed: utilization of beacons belonging to neighboring blocks and removal of the environment-reflected ultrasonic signals. As the results, the ubiquitous localization system based on iGS as a pseudo-satellite system has been developed successfully with a low cost, a high update rate, and relatively high precision.

A 4x Time-Domain Interpolation 6-bit 3.4 GS/s 12.6 mW Flash ADC in 65 nm CMOS

  • Liu, Jianwei;Chan, Chi-Hang;Sin, Sai-Weng;U, Seng-Pan;Martins, Rui Paulo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.395-404
    • /
    • 2016
  • A 6-bit 3.4 GS/s flash ADC in a 65 nm CMOS process is reported along with the proposed 4x time-domain interpolation technique which allows the reduction of the number of comparators from the conventional $2^N-1$ to $2^{N-2}$ in a N-bit flash ADC. The proposed scheme effectively achieves a 4x interpolation factor with simple SR-latches without extra clocking and calibration hardware overhead in the interpolated stage where only offset between the $2^{N-2}$ comparators needs to be calibrated. The offset in SR-latches is within ${\pm}0.5$ LSB in the reported ADC under a wide range of process, voltage supply, and temperature (PVT). The design considerations of the proposed technique are detailed in this paper. The prototype achieves 3.4 GS/s with 5.4-bit ENOB at Nyquist and consumes 12.6 mW power at 1 V supply, yielding a Walden FoM of 89 fJ/conversion-step.

Application of Organized Media for Rapid Spectrofluorimetric Determination of Trace Amounts of Cr(VI) in the Presence of Cr(III)

  • Madrakian, Tayyebeh;Afkhami, Abbas;Mohammadnejad, Masoumeh
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1252-1256
    • /
    • 2009
  • A simple, selective and sensitive fluorescence quenching method was developed to the determination Cr(VI). The method is based on the oxidation of $I^-\;to\;{{I_3}^-}$ by Cr(VI) in sulfuric acid solution followed by immediate formation of ion association compound between I3 − and rhodamine 6G in Tween-80 micellar media at room temperature. The influence of several surfactants on rhodamine 6G fluorescence signal was studied; particular attention was paid in the aggregation behavior of rhodamine 6G–Tween-80 system. The experimental parameters (e.g., type of surfactant, reagent concentration) were studied and the optimal conditions were established. The linear calibration graph was obtained in the range 2.0 - 100.0 ng m$L^{-1}$ Cr(VI). The detection limit of the method was 0.37 ng m$L^{-1}$. The relative standard deviation (R.S.D.) is less than 5% (n = 5). The efficiency of the method for the determination of Cr(VI) in the presence of Cr(III) in the sample was investigated. The method was applied successfully to the determination of Cr(VI) and total Cr in water, and liver tissue samples.

Measurement Technique for Single Phase Local Heat Transfer Coefficients of Subchannels in a Rod Bundle using a Copper Sensor (봉다발 부수로의 단상 국부열전달 계수 측정기법에 관한 연구)

  • Seo, Jeong-Sik;Choi, Young-Don;Bea, Kyong-Kuen;An, Jeong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.191-196
    • /
    • 2007
  • This paper presents the measuring technique for local heat transfer coefficients using a copper sensor in a rod bundle with mixing vanes. A copper sensor consists of a cartridge heater and four pieces of thermocouple. The Heater is located at the center of the copper sensor and thermocouples measure the surface temperature of the copper sensor. Unheated copper sensor and heated copper sensor are able to measure the local heat transfer coefficient at the position where the heated copper sensor is installed. However the entire region of a rod bundle is actually not heated, the decay of local heat transfer coefficients measured represents overestimated value rather than an actual value. The calibration curve for local heat transfer coefficients is presented using the correction factor calculated by CFD.

  • PDF

The Construction and Performance Test of Complex Networks based on Ubiquitous (유비쿼터스 기반의 복합통신망 구축 및 성능시험)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.4
    • /
    • pp.23-29
    • /
    • 2011
  • We try to build the base for implementation of smart water treatment plant through identifying status by data acquisition such as temperature, humidity, flow, level, pump status and CCTV by using USN terminal such as Zigbee, Wi-Fi, UHF at the center of the flowmeter calibration center in K-water institute. The data obtained from various sensors is transmitted to data processing device through different types of USN network, the processed data is implemented to monitor by smart phone and we try to perform low cost and high efficient USN-based pilot project by implementing remote monitoring system using network performance analysis and mobile devices.

KSR-III 과학탑재 시스템 개발

  • Hwang, Seung-Hyun;Kim, Jhoon;Chun, Young-Doo;Kim, Yong-Ha;Jang, Min-Hwan
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.83-90
    • /
    • 2002
  • This paper describes the development of scientific payload system onboard the KSR-III. The ozone detector(UVR), Langmuir electron probe(LEP), airglow photometer(AGP), and magnetometer(MAG) constitute this system. The purpose of the ozone detector is to measure the ozone density profile and the LEP measures the electron density and temperature in the ionosphere over the Korean Peninsula. The AGP detects airglow in the mesosphere over the Korean Peninsular. The MAG provides rocket attitude and the magnetic fluctuation information during the flight. With the developed payloads, the ground calibration tests and the environmental tests have been performed.

  • PDF

Synthesis of $SrTiO_3$ from the Mixtures of $SrCO_3$ and $TiO_2$ ($SrCO_3$$TiO_2$를 사용한 $SrTiO_3$의 합성반응에 관한 연구)

  • 이종권;이병하
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.1
    • /
    • pp.43-48
    • /
    • 1983
  • The formation of strontium titanate from several molar $SrCO_3$ and $TiO_2$ mixtures was studied in air and $CO_2$ gas Mixtures of $SrCO_3$ and $TiO_2$ were heated in air at 400-$600^{\circ}C$ DTA-TG was used to obtain thermal histories of simples heated in air and $CO_2$ gas. X-ray diffraction analysis was used to determine both the phase composition and the amounts of each phase present. The phase relationship of various compounds $SrTiO_3$, $Sr_2TiO_4$, $Sr_2Ti_3O_7$ and $Sr_4Ti_3O_{10}$ formed by the sintering in each composition was shown by the calibration curves. High temperature X-ray analysis was used to determine both the formation process and deformation process of each products. Small amount of SrTiO3 is formed first at the surface af contact SrTiO3 reacts with $SrCO_3$ to form Sr2TiO4 this is affected on the $CO_2$ pressure.

  • PDF

A Development Of The Portable Spirometry System Of Pressure Method Using Static Pressure In Pitot Tube (개구관에서의 정체압을 이용한 차동 압력 방식의 휴대형 호흡측정 시스템 개발)

  • 이종수;신창민;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.479-486
    • /
    • 2001
  • Spirometer is a medical equipment which diagnoses respiratory function by measuring 9as volume across Patient's lunes through airway. Because a little overdose of anesthesia medicine can take away Patient's life in the ventilator for a surgical operation. an exact measurement of respiring volume is very important. This Paper Presented an exact flow volume calculation method from factors having an influence on measurement and introduced a spirometry system for an anesthesia ventilato. This system, using differential Pressure sensor measured flow by mutual relation with Pressure. temperature. gas density and linearization from the 2nd order characteristics of differential pressure with flow.

  • PDF

A Study on the Characteristics of PCN-PZT Piezoelectric Acceleration Sensor (PCN-PZT 압전형 가속도센서의 특성에 관한 연구)

  • Kim, Yeong-Deok;Kim, Gwang-Il;Jeong, U-Cheol;Go, Jae-Seok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.354-360
    • /
    • 1999
  • PCN-PZT piezoelectric acceleration sensors of annular shear mode voltage type were fabricated and their characteristics have been investigated. Field tests are also carried out. To avoid noise problems from the environmental conditions, acceleration sensors employed solid state micro-electronics for pre-amplifier. The calibration procedures based on the principle of the comparison method were adopted for investigating the characteristics of fabricated acceleration sensors. The voltage sensitivity and resonant frequency of fabricated acceleration sensors were 83mv/g, 23kHz, respectively. The lower and upper frequency limit were 4Hz and 9kHz, respectively. The variation of the voltage sensitivity showed 10% at $-406{\circ}C\; and\; 9%\; at\; 121^{\circ}C$ compared to that of reference temperature at $40^{\circ}C$.

  • PDF