• 제목/요약/키워드: temperature calibration

검색결과 516건 처리시간 0.025초

Realization of silver fixed-point and application for the high temperature platinum resistance thermometry using the gas-pressure controlled sodium heat-pipe furnace (가스압력조절식 나트륨 열관전기로를 이용한 은 고정점 실현과 고온백금저항온도 계측에의 응용)

  • Gam, K.S.;Choi, I.M.;Yang, I.;Kim, Y.G.
    • Journal of Sensor Science and Technology
    • /
    • 제18권2호
    • /
    • pp.116-121
    • /
    • 2009
  • Pressure-controlled sodium heat pipe furnace was designed and fabricated, and its characteristics was investigated. Pressure control system was controlled within ${\pm}0.5\;Pa$ at 150 kPa and the stability of pressure was decreased to ${\pm}2.5\;Pa$, when the pressure-controlled system connected with the heat pipe. The melting curve of Ag fixed-point realized well by the adiabatic method using the pressure-controlled sodium heat pipe furnace and its accuracy showed ${\pm}2.27\;mK$ from the calculation of 20% to 80% at the plateau. The freezing curve of Ag fixed-point also realized and its plateau value was 2.23 mK lower than that of the melting curve.

Hydrodynamic Modeling of Saemangeum Reservoir and Watershed using HSPF and EFDC (HSPF-EFDC를 이용한 새만금호와 유역의 수리 변화 모의)

  • Shin, Yu-Ri;Jung, Ji-Yeon;Choi, Jung-Hoon;Jung, Kwang Wook
    • Journal of Korean Society on Water Environment
    • /
    • 제28권3호
    • /
    • pp.384-393
    • /
    • 2012
  • Saemangeum lake is an artificial lake created by reclamation works and an estuary embankment since 2006. The sea water flows into the lake by the operation of two sluice gates, and the freshwater enters into the lake by the upper streams. For the reflection of hydrology and hydrodynamics effects in Saemangeum area, a hydrodynamics model was developed by connecting Hydrological Simulation Program with Fortran (HSPF) and Environmental Fluid Dynamic Code (EFDC). The HSPF was applied to simulate the freshwater discharge from the upper steam watershed, and the EFDC was performed to compute water flow, water temperature, and salinity based on time series from 2008 to 2009. The calibration and validation are performed to analyze horizontal and vertical gradients. The horizontal trend of model simulation results is reflected in the trend of observed data tolerably. The vertical trend is conducted an analysis of seasonal comparisons because of the limitation of vertically observed data. Water temperature reflects on the seasonal changes. Salinity has an effect on the near river input spots. The impact area of salinity is depending on the sea water distribution by gate operation, mainly.

Hydro-thermal Numerical Simulation for an Artificial Recharge Test in a Fractured Rock Aquifer (암반대수층 지하수 인공함양 시험에 대한 열-수리 모델링)

  • Park, Daehee;Koo, Min-Ho;Kim, Yongcheol
    • Journal of Soil and Groundwater Environment
    • /
    • 제20권1호
    • /
    • pp.65-75
    • /
    • 2015
  • An artificial recharge test aimed at investigating transport characteristics of the injected water plume in a fractured rock aquifer was conducted. The test used an injection well for injecting tap water whose temperature and electrical conductivity were different from the groundwater. Temporal and depth-wise variation of temperature and electrical conductivity was monitored in both the injection well and a nearby observation well. A highly permeable fracture zone acting as the major pathway of groundwater flow was distinctively revealed in the monitoring data. A finite element subsurface flow and transport simulator (FEFLOW) was used to investigate sensitivity of the transport process to associated aquifer parameters. Simulated results showed that aperture thickness of the fracture and the hydraulic gradient of groundwater highly affected spatio-temporal variation of temperature and electrical conductivity of the injected water plume. The study suggests that artificial recharge of colder water in a fractured rock aquifer could create a thermal plume persistent over a long period of time depending on hydro-thermal properties of the aquifer as well as the amount of injected water.

Environment Effects on the Stability of the CQUEAN CCD

  • Choi, Nahyun;Pak, Soojong;Choi, Changsu;Park, Won-Kee;Im, Myungshin;Jeon, Yiseul;Baek, Giseon
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제37권2호
    • /
    • pp.222.2-222.2
    • /
    • 2012
  • Camera for QUasars in EArly uNiverse (CQUEAN) is an optical CCD camera attached to the 2.1m Otto Struve telescope at the McDonald Observatory, USA. CCD output signal contains the electrons generated by photoionization of incident light and thermal ionization. Therefore reliable photometric result can be obtained only under the stable condition of CCD thermal properties. We investigated the temperature dependency of the various characteristics of CQUEAN CCD chip, including bias level, dark level, gain, and quantum efficiency (QE), with the CQUEAN observation and calibration data obtained during 2012 May run. We discuss the environmental effects, i.e., ambient temperature, as well as CCD temperature on the stability of its characteristics.

  • PDF

Electron Dose Measurement with Polycarbonate Film Dosimeter

  • Yoo, Young-Soo
    • Nuclear Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.9-17
    • /
    • 1976
  • Dosimetrical properties of polycarbonate film for high-level dosimetry of electrons have been examined. Polycartonate film of 0.1mm in thickness was chosen for this purpose. It can cover the dose range of 1.0-130 Mrad and the measurable range can be extended up to 200 Mrad by using calibration curve. The measurement error was within 3.5%. The radiation induced optical density at 330nm shows rapid initial fading of 7-l3n for one day after irradiation at room temperature and subsequent fading rate is very small, about 0.6% per day. The fading depends on the absorbed dose, storage temperature, and wavelengths. The effects of storage time and temperature during and after irradiation of this film are presented. For practical dosimetry, it is necessary to stabilize the induced optical density by storing the irradiated film for a day or by heat treatment at 10$0^{\circ}C$ for an hour.

  • PDF

Drift Test Method of Meteorological Instrument for Type Approval (형식승인을 위한 측기의 드리프트 검사 방법)

  • Seo, Dae-Il;Lee, Kyung-Hun;Kwon, Byung-Hyuk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제17권5호
    • /
    • pp.927-932
    • /
    • 2022
  • Instrument drift is caused by the passage of time, environmental changes, normal wear and tear, debris buildup, sudden shock, vibrations, electromagnetic fields, and improper use. Since it is inappropriate to directly determine the change of the output value as drift during the limited test period, a new algorithm that reflects both zero drift and span drift by giving changes over time to the calibration method of the instrument was proposed. The temperature drift was calculated to be 0.49% for about 60 minutes at 1-minute intervals in the nine-step constant temperature environment through the warming and cooling process.

Retrieval of Oceanic Skin Sea Surface Temperature using Infrared Sea Surface Temperature Autonomous Radiometer (ISAR) Radiance Measurements (적외선 라디오미터 관측 자료를 활용한 해양 피층 수온 산출)

  • Kim, Hee-Young;Park, Kyung-Ae
    • Journal of the Korean earth science society
    • /
    • 제41권6호
    • /
    • pp.617-629
    • /
    • 2020
  • Sea surface temperature (SST), which plays an important role in climate change and global environmental change, can be divided into skin sea surface temperature (SSST) observed by satellite infrared sensors and the bulk temperature of sea water (BSST) measured by instruments. As sea surface temperature products distributed by many overseas institutions represent temperatures at different depths, it is essential to understand the relationship between the SSST and the BSST. In this study, we constructed an observation system of infrared radiometer onboard a marine research vessel for the first time in Korea to measure the SSST. The calibration coefficients were prepared by performing the calibration procedure of the radiometer device in the laboratory prior to the shipborne observation. A series of processes were applied to calculate the temperature of the layer of radiance emitted from the sea surface as well as that from the sky. The differences in skin-bulk temperatures were investigated quantitatively and the characteristics of the vertical structure of temperatures in the upper ocean were understood through comparison with Himawari-8 geostationary satellite SSTs. Comparison of the skin-bulk temperature differences illustrated overall differences of about 0.76℃ at Jangmok port in the southern coast and the offshore region of the eastern coast of the Korean Peninsula from 21 April to May 6, 2020. In addition, the root-mean-square error of the skin-bulk temperature differences showed daily variation from 0.6℃ to 0.9℃, with the largest difference of 0.83-0.89℃ at 1-3 KST during the daytime and the smallest difference of 0.59℃ at 15 KST. The bias also revealed clear diurnal variation at a range of 0.47-0.75℃. The difference between the observed skin sea surface temperature and the satellite sea surface temperature showed a mean square error of approximately 0.74℃ and a bias of 0.37℃. The analysis of this study confirmed the difference in the skin-bulk temperatures according to the observation depth. This suggests that further ocean shipborne infrared radiometer observations should be carried out continuously in the offshore regions to understand diurnal variation as well as seasonal variations of the skin-bulk SSTs and their relations to potential causes.

Pressure-load Calibration of Multi-anvil Press and the Thermal Gradient within the Sample Chamber (멀티 앤빌 프레스의 압력-부하 보정 작업과 시료 내의 온도구배 연구)

  • Kim, Eun Jeong;Lee, Sung Keun
    • Journal of the Mineralogical Society of Korea
    • /
    • 제31권3호
    • /
    • pp.161-172
    • /
    • 2018
  • Multi-anvil press (MAP) is one of the high pressure apparatuses and often generates the pressure-conditions ranging from 5 to 25 GPa and temperature-conditions up to $2,300^{\circ}C$. The MAP is, therefore, suitable to explore the pressure-induced structural changes in diverse earth materials from Earth's mantle and the bottom of the mantle transition zone (~660 km). In this study, we present the experimental results for pressure-load calibration of the 1,100-ton multi-anvil press equipped in the authors' laboratory. The pressure-load calibration experiments were performed for the 14/8 step, 14/8 G2, 14/8 HT, and 18/12 assembly sets. The high pressure experiments using ${\alpha}$-quartz, wollastonitestructure of $CaGeO_3$, and forsterite as starting materials were analyzed by powder X-ray diffraction spectroscopy. The phase transition of each mineral indicates the specific pressure that is loaded to a sample at $1,200^{\circ}C$: a transition of ${\alpha}$-quartz to coesite at 3.1 GPa, that of garnet-structure of $CaGeO_3$ to perovskite-structure at 5.9 GPa, that of coesite to stishovite at 9.2 GPa, and that of forsterite to wadsleyite at 13.6 GPa. While the estimated pressure-load calibration curve is generally consistent with those obtained in other laboratories, the deviation up to 50 tons is observed at high pressure above 10 GPa. This is partly because of the loss of oil pressure at high pressure resulting from the differences in a sample chamber, and the frictional force between pressure medium and second anvil. We also report the ${\sim}200^{\circ}C/mm$ of thermal gradient in the vertical direction of the sample chamber of 14/8 HT assembly. The pressure-load calibration curve and the observed thermal gradient within the sample chamber can be applied to explain the structural changes and the relevant macroscopic properties of diverse crystalline and amorphous earth materials in the mantle.

Mathematical Prediction of the Lunar Surface Temperature Using the Lumped System Analysis Method (집중계 해석법을 이용한 달 표면온도 예측)

  • Kim, Taig Young;Lee, Jang-Joon;Chang, Su-Young;Kim, Jung-Hoon;Hyun, Bum-Seok;Cheon, Hyeong Yul;Hua, Hang-Pal
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제46권4호
    • /
    • pp.338-344
    • /
    • 2018
  • The lunar surface temperature is important as a environmental parameter for the thermal design of the lunar exploration vehicles such as orbital spacecraft, lander, and rovers. In this study, the temperature is numerically predicted through a simplified lumped system model for the energy conservation. The physical values required for the analysis of the energy equation are derived by considering the geometric shape, and the values presented in the previous research results. The areal specific heat, which is the most important thermo-physical property of the lumped system model, was extracted from the temperature measurements by the Diviner loaded on the LRO, and the value was predicted by calibration of the analytical model to the measurements. The predicted temperature distribution obtained through numerical integration has sufficient accuracy to be applied to the thermal design of the lunar exploration vehicles.

A Design of Output Voltage Compensation Circuits for Bipolar Integrated Pressure Sensor (바이폴라 공정을 이용한 압력센서용 출력전압 보상회로의 설계)

  • Lee, Bo-Na;Kim, Kun-Nyun;Park, Hyo-Derk
    • Journal of Sensor Science and Technology
    • /
    • 제7권5호
    • /
    • pp.300-305
    • /
    • 1998
  • In this paper, integrated pressure sensor with calibration of offset voltage and full scale output and temperature compensation of offset voltage and full scale output were designed. The signal conditioning circuitry are designed that calibrate the offset voltage and full scale output to desired values and minimize the temperature drift of offset voltage and full scale output. Designed circuits are simulated using SPICE in a bipolar technology. The ion implanted resistor of different temperature coefficient were used to trimming the desired values. As a results, offset voltage was calibrated to 0.133V and the temperature drift of offset voltage was reduced to $42\;ppm/^{\circ}C$. Also, the full scale output was calibrated to 4.65V and the temperature coefficient of full scale output was reduced to $40ppm/^{\circ}C$ after temperature compensation.

  • PDF