• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.03 seconds

A LPG Dispensing Control System based on a 16-bit Microprocessor (16-bit 마이크로프로세서로 구현한 LPG 충전 제어 시스템)

  • 이상훈;홍남관
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2002
  • In this paper, a POS interfacing and temperature compensable LPG dispensing control system(LDCS) has been developed. A LDCS includes a 16-bit 80C196 microprocessor, RAM, ROM, video driver, and programmable peripheral devices. Based on gas flow encoding pulse, temperature-voltage conversion values and apparatus calibration values, the LDCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with a 10-bit A/D conversion and its range is from +7$0^{\circ}C$ to -3$0^{\circ}C$ with a 0.5$^{\circ}C$ resolution.

  • PDF

Multiplexed fabry-perot interferometric sensor system (다중화 Fabry-Perot 간섭형 광섬유 센서 시스템)

  • 나도성;예윤해;이동영;박광순
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.273-278
    • /
    • 1999
  • A TDM-multiplexed fiber optic pressure/temperature sensor system utilizing fiber optic Fabry-Perot interferometers as sensing devices was developed and applied to measure water level variations and temperature variations. The maximum measurement speed of the system without saving measurement data is 4500 times per second and the response time of the sensors is thought to be ~ms. The difference between the theoretical value and the measured value for the scale factor of water level sensor and temperature sensor was +13.7%, -18% respectively. The nonlinearity of the sensors after calibration was less than 1%. The sensor system was applied to verify the capability of measuring the temperature variations and water level variations at a high speed.

  • PDF

A Statistic Correlation Analysis Algorithm Between Land Surface Temperature and Vegetation Index

  • Kim, Hyung-Moo;Kim, Beob-Kyun;You, Kang-Soo
    • Journal of Information Processing Systems
    • /
    • v.1 no.1 s.1
    • /
    • pp.102-106
    • /
    • 2005
  • As long as the effective contributions of satellite images in the continuous monitoring of the wide area and long range of time period, Landsat TM and Landsat ETM+ satellite images are surveyed. After quantization and classification of the deviations between TM and ETM+ images based on approved thresholds such as gains and biases or offsets, a correlation analysis method for the compared calibration is suggested in this paper. Four time points of raster data for 15 years of the highest group of land surface temperature and the lowest group of vegetation of the Kunsan city Chollabuk_do Korea located beneath the Yellow sea coast, are observed and analyzed their correlations for the change detection of urban land cover. This experiment based on proposed algorithm detected strong and proportional correlation relationship between the highest group of land surface temperature and the lowest group of vegetation index which exceeded R=(+)0.9478, so the proposed Correlation Analysis Model between the highest group of land surface temperature and the lowest group of vegetation index will be able to give proof an effective suitability to the land cover change detection and monitoring.

Fabrication and Characteristic of an InSb Mognetic Flvxmeter (InSb 자속계의 제작과 그 특성에 관한 연구)

  • 윤재강;유용택
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.6
    • /
    • pp.5-8
    • /
    • 1975
  • An Insb magnetic fluxmeter was made of InSb Single Crystal that was grown by Bridgemannmethods and then purified by vapor cone refining method. We investigated some properties of the InSb magneto fluxmeter. It was found that the resistivity and the Hall Coefficient of this single Crystal Were 4.4${\times}10^{-2}{\Omega}$ and $4.5\textrm{cm}^3$/Coul, respectively, at room temperature. The Characteristic Curve of the InSb magnetic fluxmeter between the magnetic field the Hall voltage, with the Current flowing through the element a Parameter, had good lineanty i.e., We obtained a linear Calibration Curve of the flwmeter. The fluxmeter erved the purpose well enough up to 5 k-gaus.

  • PDF

Image Radiometric Quality Assessment of the Meteorological Payload on GEO-KOMPSAT-2A (정지궤도복합위성 기상탑재체 영상의 복사 성능 품질 측정)

  • Jin, Kyoung-Wook;Yang, Koon-Ho;Choi, Jae-Dong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.30-39
    • /
    • 2013
  • In this study, calibration processes and methods of evaluating the radiometric quality of satellite images from the meteorological payload on the GEO-KOMPSAT-2A were described. MTF(Modulation Transfer Function), SNR(Signal-To-Noise Ratio), NEdT(Noise Equivalent Delta Temperature), and Dynamic Range, which are the major parameters for assessment of data radiometric quality of space-borne visible and infrared sensors, are focused. Key process of the quality check of the satellite data is the comparing the image radiometric performance parameters during the In-Oribit Test with those acquired from the ground tests. Validation plan of the image quality of the GEO-KOMPSAT-2A Meteorological Imager is addressed based on the analyses results of COMS MI data during the COMS In-Orbit Test period

A Modeling Study of Lake Thermal Dynamics and Turbid Current for an Impact Prediction of Dam Reconstruction (댐 재개발이 호수 수온 및 탁수 거동 변화에 미치는 영향 예측을 위한 모델 연구)

  • Jeong, Seon-A;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.813-821
    • /
    • 2005
  • This paper presents a modeling study of thermal dynamics and turbid current in the Obong Lake, Kangreung. The lake formed by the artificial dam in 1983 for agricultural water supply, is currently under consideration of reconstruction in order to expand the volume of reservoir for water supply and flood control in downstream area. The US Army Corps of Engineers' CE-QUAL-W2, a two-dimensional laterally averaged hydrodynamic and water quality model, was applied to the lake after reconstruction as well as the present lake. The model calibration and verification were conducted against surface water levels and temperature of the lake measured during the years of 2001 and 2003. The model results showed a good agreement with fold measurements both in calibration and verification. Utilizing the validated model, an impact of dam reconstruction on vertical temperature and hydrodynamics were predicted. The model results showed that steep temperature gradient between epilimnion and hypolimnion would be formed during summer, along with extension of cold deep water after reconstruction. During winter and spring seasons, however, the vertical temperature profiles was predicted to be quite similar both before and after reconstruction. This results indicated that thermal stratification would become stronger during summer and stay longer after dam reconstruction. From the examination of predicted water movements, it was noticed that the upstream turbid current would infiltrate into the interface between metalimnion and hypolimnion and then suspended solids would slowly settle down to the bottom before reconstruction. After reconstruction, however, it was shown that the upstream turbid current would stay longer in metalimnion with similar density due to strong stratification. The model also predicted that dam reconstruction would make suspended solids near the dam location significantly decrease.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

Measurement of combustor surface temperature using phosphor thermometry (형광체를 이용한 연소기 표면온도 측정기술)

  • Kim, Yong-Gyoo;Lee, Seok Hwan;Kim, Sunghun;Yang, Inyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.228-231
    • /
    • 2017
  • The surface temperature of a combustor such as an aircraft engine is one of the important measuring factors related to the combustion performance. However, a conventional temperature measurement technique have a large measurement error due to a bad environment such as a combustion flame, vibration, and dust. In order to solve this problem, a technology has been developed which can measure the surface temperature of the combustor in real time using the wavelength change or attenuation time change according to the temperature of the phosphor. In this study, we developed a technique that can measure surface temperature of scram-jet combustor using phosphor thermometry. The calibration curve was obtained according to the temperature from $200^{\circ}C$ to $800^{\circ}C$ in the calibrated temperature chamber. So, we confirmed that phosphor thermometry can be used for measuring surface temperature of scram-jet combustor.

  • PDF

Intake Valve Temperature Effect on the Mixture Preparation in a SI Engine During Warm-up

  • 신영기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.51-66
    • /
    • 1997
  • A heat transfer model of the intake valve in a spark ignition engine is presented, which is calibrated with a number of the valve temperature profiles measured during engine warm-up for the gaseous fuel(propane). The valve is divided into four identical elements for which the assumption of lumped thermal mass is applied. The calibration is made so that the difference between the measued and simulated valve temperatures becomes minimal. Then the model is applied to the cases of the liquid fuel(indolene) to estimate the amount of the liquid fuel vaporized from the intake valve by assuming that fuel evaporation accounts for the deficit of the heat balance budget. The results of the model show quantitative contribution of each heat transfer source to the heat balance. The behavior of the calculated mass fraction of the fuel vaporized from the intake valve explains how the liquid fuel evaporate during engine warm-up. The mass fraction at warmed-up condition is closely related with the fraction directly targeted on the valve back by the fuel spray geometry.

  • PDF

Determination of the interface heat transfer coefficient for hot-forming process of Ti-6Al-4V (Ti-6Al-4V 합금의 열간성형공정에 대한 계면열전달계수의 결정)

  • 염종택;임정숙;나영상;박노광;신태진;황상무;심인옥
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.299-302
    • /
    • 2003
  • The interface heat transfer coefficient was measured for non-isothermal bulk forming of Ti-6Al-4V. FE analysis and experiments were conducted. Equipment consisting of AISI H13 die was instrumented with thermocouples located at sub-surface of the bottom die. Die temperature changes were investigated in related to the process variables such as reduction, lubricant and initial die temperature. The calibration approach based on heat conduction and FE analysis using an inverse algorithm were used to evaluate the interface heat transfer between graphite-lubricated die and glass-coated workpiece. The coefficients determined determined were affected mainly by the contact pressure. The validation of the coefficients was made by the comparison between experimental data and FE analysis results.

  • PDF