• Title/Summary/Keyword: temperature and relative humidity

Search Result 1,757, Processing Time 0.034 seconds

Enhanced Graft-take Ratio and Quality of Grafted Tomato Seedlings by Controlling Temperature and Humidity Conditions (토마토 공정묘의 접목활착율과 묘소질 향상을 위한 접목 활착실내의 적정 온.습도 조건 구명)

  • Vu, Ngoc-Thang;Zhang, Cheng-Hao;Xu, Zhi-Hao;Kim, Young-Shik;Kang, Ho-Min;Kim, Il-Soep
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.146-153
    • /
    • 2013
  • This study was conducted to enhance graft-take ratio and quality of grafted tomato seedlings by controlling temperature and humidity during the healing and acclimatization processes. Three temperature levels ($20^{\circ}C$, $23^{\circ}C$, and $26^{\circ}C$) were carried out to determine optimum temperature on four rootstocks. In addition, twelve combinations of three relative humidity levels (70%, 80%, and 90%) and four temperature levels ($17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$, and $26^{\circ}C$) were set up to evaluate the effect of relative humidity and temperature on the graft-take ratio of grafted seedlings. In the other hand, five relative humidity periods (H0, H1, H2, H3, and H4: 90% relative humidity for first 0, 1, 2, 3 and 10 days and afterwards relative humidity was reduced to 70%, respectively) were examined effect of relative humidity periods on the graft-take and quality of grafted seedlings. The higher graft-take ratios (84.0~87.4%) were showed at $23^{\circ}C$ compared to $20^{\circ}C$ and $26^{\circ}C$ in all rootstocks. Graft-take ratios decreased and number of diseased plants increased at high temperature. The graft-take ratios increased with increasing relative humidity in all temperature levels on the $3^{rd}$ and $7^{th}$ day after grafting. However, increasing relative humidity significantly increased percent of diseased plants. The graft-take ratio reduced at ($26^{\circ}C$) and ($17^{\circ}C$) temperature under all relative humidity conditions. The graft-take ratio increased with increasing period of 90% relative humidity. Maximum graft-take ratios were observed in H2 and H3 treatments. Graft-take ratio decreased with increasing 90% relative humidity for 10 days (H4). Diseased plants had not been found in H0, H1, H2, and H3 treatments. Seedling quality was improved through increasing fresh and dry weight of root, compactness, and root morphology of tomato seedlings in H2 and H3 treatments. Therefore, high relative humidity (90%) for first 2 or 3 days and afterwards reduced low relative humidity (70%) at $23^{\circ}C$ condition during healing and acclimatization promoted the graft-take and quality of grafted tomato seedlings.

A Study on Prediction of Temperature and Humidity for Estimation of Cooling Load (냉방부하 추정을 위한 온도와 습도 예측에 관한 연구)

  • Yoo, Seong-Yeon;Lee, Je-Myo;Han, Kyou-Hyun;Han, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.394-402
    • /
    • 2007
  • To estimate the cooling load for the following day, outdoor temperature and humidity are needed in hourly base. But the meteorological administration forecasts only maximum and minimum temperature. New methodology is proposed for predicting hourly outdoor temperature and humidity by using the forecasted maximum and minimum temperature. The correlations for normalized outdoor temperature and specific humidity has been derived from the weather data for five years from 2001 to 2005 at Seoul, Daejeon and Pusan. The correlations for normalized temperature are independent of date, while the correlations for specific humidity are linearly dependent on date. The predicted results show fairly good agreement with the measured data. The prediction program is also developed for hourly outdoor dry bulb temperature, specific humidity, dew point, relative humidity, enthalpy and specific volume.

Variations of Air Temperature, Relative Humidity and Pressure in a Low Pressure Chamber for Plant Growth (식물생장용 저압챔버 내의 기온, 상대습도 및 압력의 변화)

  • Park, Jong-Hyun;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.200-207
    • /
    • 2009
  • This study was conducted to analyze the variations of air temperature, relative humidity and pressure in a low pressure chamber for plant growth. The low pressure chamber was composed of an acrylic cylinder, a stainless plate, a mass flow controller, an elastomer pressure controller, a read-out-box, a vacuum pump, and sensors of air temperature, relative humidity, and pressure. The pressure leakage in the low pressure chamber was greatly affected by the material and connection method of tubes. The leakage rate in the low pressure chamber with the welding of the stainless tubes and a plate decreased by $0.21kPa{\cdot}h^{-1}$, whereas the leakage in the low pressure chamber with teflon tube and rubber O-ring was given by $1.03kPa{\cdot}h^{-1}$. Pressure in the low pressure chamber was sensitively fluctuated by the air temperature inside the chamber. An elastomer pressure controller was installed to keep the pressure in the low pressure chamber at a setting value. However, inside relative humidity at dark period increased to saturation level.. Two levels (25 and 50kPa) of pressure and two levels (500 and 1,000sccm) of mass flow rate were provided to investigate the effect of low pressure and mass flow rate on relative humidity inside the chamber. It was concluded that low setting value of pressure and high mass flow rate of mixed gas were the effective methods to control the pressure and to suppress the excessive rise of relative humidity inside the chamber.

Influence of Relative Humidity on the Temperature Increase of a Power Converter

  • Xu, Yang;Chen, Hao;Hu, Zhentao;Li, Dong
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.841-848
    • /
    • 2015
  • As a vital part of renewable energy and electrical traction, power converters are supposed to have high reliability and good performance. However, power semiconductors produce considerable heat when the power converter works, which results in high junction temperatures that lower the reliability and performance of the power semiconductors. Many studies show that ambient humidity has a significant effect on power devices, but the influence of high humidity on junction temperatures has yet to be studied. Therefore, this paper presents a thermal model for power converters in moist air to obtain the junction temperature increase, which is utilized for the power converter used in a Switched Reluctance Motor System. Simulation results show that the law of converter temperature distribution is independent of the relative humidity in the case of fixed ambient temperature, whereas the temperature in the power converter decreases as the ambient relative humidity increases. These simulation results are validated with the experimental results.

A Study on the Characteristics of Environmental Factors of Granite Dome Models with Different Material during Winter Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.71-76
    • /
    • 2001
  • Factors governing the rate of heat exchange comprise temperature, air velocity, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment in different envelop structures using granite dome models. The interior relative humidity is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF

A study on the characteristics of environmental factors of granite dome models with different envelope structures in winter (외피 유형별 석재 모형돔의 동절기 환경 특성에 관한 연구)

  • 공성훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.642-646
    • /
    • 1999
  • Factors governing the rate of heat exchange comprise the air temperature, the speed of air movement, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as the dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment with the different envelope structures using a granite dome model. According to the variation of humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

Characteristics of Meteorological Environment Variation Before and After Construction of Nak-dong River Estuary Barrage (낙동강 하구둑 건설 전·후의 기상환경 변화 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.135-145
    • /
    • 2005
  • This study was conducted to investigate the characteristics of meteorological environment variation before and after construction of Nak-dong river estuary barrage. We used meteorological data(air temperature, precipitation, relative humidity, visibility, wind) at Gimhae airport meteorological station. The construction of river estuary barrage can change climate at the neighboring districts and influence human's health and vegetable. The construction of Nakdong river estuary barrage brought rise of temperature, decrease of relative humidity and increase of poor visibility frequency.

A study on the Characteristics of Urban Dryness in Daegu (대구의 도시건조화 특성에 관한 연구)

  • Park, Myung-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.171-178
    • /
    • 2007
  • It is well known that urban relative humidity has continuous decreasing trend owing to the influence of urbanization. The change of relative humidity is directly influenced by two factors, namely, temperature effect and water vapor effect in various urban effects. In this study, the temperature and tile water vapor effects on the relative humidity change were analyzed by using monthly mean relative humidities for a long period($1961{\sim}2005$) in Daegu and Chupungnung. The major results obtained in this study can be summarized as follows. Firstly, the urban dryness was caused mainly by water vapor effect in summer. But, for the other seasons, the urban dryness is mainly due to the temperature effect. Secondly, the relative humidity in Daegu is on the decrease until now. This phenomenon is similar to another Korean huge cities such as Seoul, Daejeon and Incheon. But, it is different compared with Japanese huge cities such as Tokyo, Osaka and Nagoya, indicating a standstill in relative humidity change after 1980s.

Development of an Environmental Control System for Agricultural Storage Facility (상온저장 시설의 환경 제어 시스템 개발)

  • 임종환;현명택
    • Food Science and Preservation
    • /
    • v.4 no.2
    • /
    • pp.101-113
    • /
    • 1997
  • Temperature, relative humidity and ventilation are closely related one another, and they are the main factors to be controlled for the environmental control system of a storage facility. Conventional environmental control systems do not consider the interrelationship between temperature, relative humidity and ventilation, which results in low performance and high energy consumption. To overcome the inefficiency of the conventional ones, it was developed an on-off control system based on the interrelationship between the factors. The usefulness of the system was illustrated with the results produced by a set of experiments in a real world.

  • PDF

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Low-Priced Generic Ceramic Panel Materials for Humidity Control - Focuses on analyzed measurements of temperature and humidity obtained from the housing units - (저가보급형 습도조절용 세라믹패널의 조습성능 평가 - 리빙랩 온·습도 모니터링 분석을 통한 실측결과를 중심으로 -)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.39-40
    • /
    • 2017
  • This study aims to evaluate the humidity control performance of low-priced generic ceramic panels that are used to control humidity. Temperature and humidity are monitored by using 'Living Lab' and the change of indoor relative humidity is measured and analyzed. According to the results of the study, the indoor relative humidity of rooms installed with ceramic panels was found to be low compared to that of living rooms by 2.2%RH (test period) and 3.2%RH (daily). In the case of maximum relative humidity, rooms installed with ceramic panels were found to be low by 6.9%RH. The results are attributable to the humidity absorption of ceramic panels. Accordingly, future ceramic panels need the improvement of performance and an appropriate construction area should be derived depending on indoor space.

  • PDF