• 제목/요약/키워드: temperature and relative humidity

검색결과 1,757건 처리시간 0.029초

A Comparative Functionality Evaluation of Paulownia Wood Storage Boxes and Acid-free Archival Boxes to Store the Annals of Joseon Dynasty - Indoor and Outdoor Temperature and Relative Humidity Controls, and Heat Release Rate -

  • Park, Hae Jin;Kim, Seong Eun;Lee, Jin Kyung;Chung, Yong Jae
    • 보존과학회지
    • /
    • 제38권1호
    • /
    • pp.72-79
    • /
    • 2022
  • A paulownia wood has been widely used with various advantages as its low weight, permeability, convenient workability and aesthetic patterns for a long time. However, the related empirical researches and simultaneous evaluations of functionality are insufficient compared with acid-free archival boxes for now. In this study, the indoor and outdoor temperature and relative humidity control and heat release rate were evaluated under the controlled and uncontrolled circumstance in 2018. The paulownia wood storage box showed superior control effect of relative humidity than the acid-free archival box in constantly uncontrolled environment. Also, the possibility of the flame diffusion from the surface of the materials was higher for the paulownia materials, and the acid-free archival box showed more dangerous patterns in the early stages of the fire.

단립종 벼의 수분흡습특성 (Adsorption Characteristics of Short Grain Rough Rice)

  • 김종순;고학균;송대빈
    • Journal of Biosystems Engineering
    • /
    • 제23권5호
    • /
    • pp.465-472
    • /
    • 1998
  • In this study short gain rough rice(Chu-cheong) with initial moisture content of around 12%(w.b.) was exposed to 3 levels of relative humidity(70, 80 and 90%) and 3 levels of temperature(20, 25 and 3$0^{\circ}C$) of the air, in order to evaluate the adsorption characteristics of rough rice and the rate of cracked kernels which will serve as the basic data when developing the quality adjusting equipment. The result showed that the moisture content of rough rice increased rapidly during the early stages of moisture adsorption like other grains, and at least 70% of the adsorption occurred within the first 24 hours of exposure to the humid environment. Adsorption rate was more related to relative humidity than the temperature of air stream, and the higher the relative humidity, the higher the adsorption rate. And the Page's equation predicted best the adsorption process of this study. Experimental results for the crack generation during the adsorption process showed that the higher the relative humidity the more the cracked kernels, and that the temperature had little effect. An empirical equation was developed to predict the crack ratio for the conditions of this study, and Nishiyama model predicted better the crack generation than Hoerl model.

  • PDF

드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정 (Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone)

  • 김희상;박용희;김우영;은희람;안강호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

An Integrated Sensor for Pressure, Temperature, and Relative Humidity Based on MEMS Technology

  • Won Jong-Hwa;Choa Sung-Hoon;Yulong Zhao
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.505-512
    • /
    • 2006
  • This paper presents an integrated multifunctional sensor based on MEMS technology, which can be used or embedded in mobile devices for environmental monitoring. An absolute pressure sensor, a temperature sensor and a humidity sensor are integrated in one silicon chip of which the size is $5mm\times5mm$. The pressure sensor uses a bulk-micromachined diaphragm structure with the piezoresistors. For temperature sensing, a silicon temperature sensor based on the spreading-resistance principle is designed and fabricated. The humidity sensor is a capacitive humidity sensor which has the polyimide film and interdigitated capacitance electrodes. The different piezoresistive orientation is used for the pressure and temperature sensor to avoid the interference between sensors. Each sensor shows good sensor characteristics except for the humidity sensor. However, the linearity and hysteresis of the humidity sensor can be improved by selecting the proper polymer materials and structures.

Girdle 착용이 인체생리반응과 의복기후에 미치는 영향 (A Study on the Physiological Responses and the Microclimate in Girdle)

  • 김현식;최정화
    • 한국의류학회지
    • /
    • 제11권2호
    • /
    • pp.57-67
    • /
    • 1987
  • The purpose of this study was to confirm the effects of girdle on the physiological responses and the microclimate in summer. The measuring points were rectal temperature, skin temperature, pulse rate and sweat volume as physiological responses and the inside clothing temperature, relative humidity as microclimate when the subjects wore girdle (girdle A; polyurethan+nylon, girdle B; polyurethan+cotton) for the period of rest and exercise in climate chamber. The enviromental conditions were at $25^{\circ}C$ ($65{\pm}5\%$ RH) and $30^{\circ}C$ ($75{\pm}5\%$ RR). The results were as followings. 1. Mean skin temperature increased in girdle during the exercise at $30^{\circ}C$. 2. The pulse rate decreased in girdle during the rest at $25^{\circ}C$. In the case of girdle A, it was remarkably decreased. Rectal temperature increased in girdle A and B during the exercise at $25^{\circ}C$. But the kinds of girdle didn't affect the pulse rate and rectal temperature. 3. The total sweat volume in girdle was larger than in control. 4. The difference between skin temperature and inside clothing temperature of abdomen had a tendency to increase at all experiment condition. 5. The relative humidity of inside ($RH_1$) and outside ($RH_2$) of girdle increased in girdle during the rest at $25^{\circ}C$ and $30^{\circ}C$. And the relative humidity of wearing girdle B was hig-her than girdle A during the rest at $25^{\circ}C$ and $30^{\circ}C$. The $RH_1$ after stepping at $30^{\circ}C$ was the highest in girdle A and the lowest in control. From this point of view, we concluded that physiological responses and the microclimate were affected by wearing girdle. And mean skin temperature and relative humidity of inside clothing were affected by the materials of girdle.

  • PDF

표고버섯의 건조 특성 및 주요성분의 변화 1. 건조특성 및 건조모델 (Drying Characteristics and Content Change of Major Components of Shiitake Mushroom (Lentinus erodes) 1. Drying Characteristics and Drying Model)

  • 최병민;서재신;최주호
    • 한국식품저장유통학회지
    • /
    • 제4권3호
    • /
    • pp.271-278
    • /
    • 1997
  • Drying of Shiitake mushroom was investigated to see the effect of temperature, relative humidity of drying air and diameter of the pileus on its rates. The drying rate was increased with the increase of the air temperature and the decrease of the relative humidity. The external color was dark brown at higher drying temperature and higher relative humidity. Exponential and Thompson nodel were found to describe well the raying process of the Shiitake mushroom.

  • PDF

Probabilistic evaluation of chloride ingress process in concrete structures considering environmental characteristics

  • Taisen, Zhao;Yi, Zhang;Kefei, Li;Junjie, Wang
    • Structural Engineering and Mechanics
    • /
    • 제84권6호
    • /
    • pp.831-849
    • /
    • 2022
  • One of the most prevalent causes of reinforced concrete (RC) structural deterioration is chloride-induced corrosion. This paper aims to provide a comprehensive insight into the environmental effect of RC's chloride ingress process. The first step is to investigate how relative humidity, temperature, and wind influence chloride ingress into concrete. The probability of initiation time of chloride-induced corrosion is predicted using a probabilistic model that considers these aspects. Parametric analysis is conducted on several factors impacting the corrosion process, including the depth of concrete cover, surface chloride concentration, relative humidity, and temperature to expose environmental features. According to the findings, environmental factors such as surface chloride concentration, relative humidity and temperature substantially impact on the time to corrosion initiation. The long- and short-distance impacts are also examined. The meteorological data from the National Meteorological Center of China are collected and used to analyze the environmental characteristics of the chloride ingress issue for structures along China's coastline. Finally, various recommendations are made for improving durability design against chloride attacks.

SELECTION OF THE SENSORS FOR THE ENVIRONMENTAL CONTROL SYSTEMS OF PIG-HOUSING IN TEMPERATE ZONE

  • Chang, Dong-Il;Chang, Hong-Hee
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1126-1135
    • /
    • 1996
  • This study was conducted to select the sensors for measuring temperature, relative humidity, and air velocity among the major environmental factors affecting the pig productivity as a part of the study for the optimum production system model development of pig-housing. The study results are summarized as the follows : Two sensors , HMP233L and HANI, were tested for measuring temperature and relative humidity , Test results were analyzed by the statistical methods. And the sensor, HMP233L was selected as a proper sensor for temperature sand relative humidity measurement . An air velocity sensor was tested. Test results showed that its accuracy was low and incongruent for the air velocity measurement when it was lower than 4m/s.

  • PDF

벼의 저온 박층건조모델 (Low Temperature Thin Layer Drying Model of Rough Rice)

  • 김훈;금동혁;김의웅
    • Journal of Biosystems Engineering
    • /
    • 제29권6호
    • /
    • pp.495-500
    • /
    • 2004
  • This study was performed to develop thin layer drying equations for low temperature. Thin layer drying tests of short grain rough rice were conducted at three low temperature levels of 15, 25, $35^{\circ}C$ and two relative humidity levels of 30, $50\%$, respectively. The measured moisture ratios were fitted to the selected four drying models (Page, Thompson, Simplified diffusion and Lewis model) using stepwise multiple regression analysis. The overall drying rate increased as the drying air temperature was increased and as relative humidity was decreased, but the effect of temperature increase was dominant. Half response time (Moisture ratio=0.5) of drying was affected by both drying temperature and relative humidity at drying temperature of below $25^{\circ}C$, but at $35^{\circ}C$ was mainly affected by drying temperature. The results of comparing coefficients of determination and root mean square error of moisture ratio for low drying models showed that Page model was found to fit adequately to all drying test data.

Humidity Calibration for a Pressure Gauge Using a Temperature-Stable Quartz Oscillator

  • Suzuki, Atsushi
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.124-127
    • /
    • 2016
  • Humidity calibration for a temperature-stable quartz oscillator (TSQO) was investigated to exclude the influences of relative humidity on the TSQO output in order to use the corresponding devices outdoors. The TSQO output is a voltage that is inversely proportional to the electric impedance of the quartz oscillator, which depends on the viscosity and density of the measured gas. The TSQO output was humidity calibrated using its humidity dependence, which was obtained by varying the relative humidity (RH) from 0 to 100 RH% while other conditions were kept constant. The humidity dependencies of the TSQO output were fit by a linear function. Subtracting the change in the TSQO output induced by the change in humidity, calculated with the function from the experimentally measured TSQO output for a range of 0-100RH%, eliminated the influence of humidity on the TSQO output. The humidity calibration succeeded in reducing the fluctuations of the TSQO output from 0.4-3% to 0.1-0.3% of the average values for a range of 0-100RH%, at constant temperatures. The necessary stability of the TSQO output for application in hydrogen sensors was below one-third of the change observed for a hydrogen leakage of 1 vol.% hydrogen concentration, corresponding to 0.33% of the change in each background. Therefore, the results in this study indicate that the present humidity calibration effectively suppresses the influence of humidity, for the TSQO output for use as an outdoor hydrogen sensor.