• Title/Summary/Keyword: temperature and humidity variation

Search Result 303, Processing Time 0.03 seconds

A Study on the Plasma Biochemical Indices of Heat-Stressed Broilers

  • Lin, H.;Du, R.;Gu, X.H.;Li, F.C.;Zhang, Z.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.9
    • /
    • pp.1210-1218
    • /
    • 2000
  • Four experiments were conducted to evaluate the effect of temperature and humidity on biochemical indices of Arbor Acres broilers at different weeks of age. The alkaline phosphatase (AKP), acid phosphatase (ACP), lactic dehydrogenase (LD), creatine kinase (CK), plasma glucose (Glu), calcium (Ca), potassium (K), chloride (Cl), urea nitrogen (UN), uric acid (UA), plasma thyroxin (T4), triiodothyronine (T3) and insulin levels were determined in all the four experiments. In experiment 1, the plasma Glu, LD and CK levels were increased by heat exposure ($35{^{\circ}C}$ and 35, 60, or 85% RH, 2 h) and this effect was aggravated by longer exposure (24 h). No significant changes (p>0.05) were found in Ca concentration, activity of AKP and ACP. In experiment 2, temperature (10, 20, 30, $33{^{\circ}C}$) had significant effect on the levels of K, Cl, UN, UA levels and the activity of LD (p<0.01), but had no significant influence on the activity of CK (p>0.05). The UN, UK and LD levels were elevated by low temperature $(10{^{\circ}C})$ (p<0.01), Cl content was increased by high temperature ($(33{^{\circ}C})$ (p<0.01), and K level was decreased by high ($(33{^{\circ}C})$ or low $(10{^{\circ}C})$ temperature and increased by medium temperature $(30{^{\circ}C})$ (p<0.01). The humidity (35, 85% RH) only had significant effect on Cl concentration which was decreased by high humidity (p<0.01). In experiment 3, the result showed that only the LD and CK activity were significantly increased (p<0.01) by high temperature (7, 24, 28, $32{^{\circ}C}$) or high humidity (35, 85% RH). Temperature and humidity had no significant effect on K, Cl, UA, UN and Glu levels (p>0.05). In experiment 4 (24, 27, 30, $33{^{\circ}C}$; 30, 45, 60, 75, 90% RH), plasma T3 level was declined by high temperature $(33{^{\circ}C})$, and this phenomena disappeared in birds under high temperature and high humidity environment. T4 concentration in plasma was not affected by temperature (p>0.05), but was increased by high or low humidity (p<0.01). Neither temperature nor humidity had significant effect on plasma insulin concentration (p>0.05). The results of the four experiments suggested that broilers at different growth periods might have different thermal requirements and would response differently to heat exposure. The plasma biochemical indices themselves had big variation; the reaction of the indices to thermal exposure treatment differed with the age of broilers. The big variation of biochemical indices themselves might cover the response of indices to temperature and humidity treatments.

Analysis for Temperature and Relative Humidity of Showcase in Exhibition Hall Operated Intermittent Air Conditioning (간헐공조 전시관내 유물 진열장의 온·습도 환경 분석)

  • Lee, Sun Myung;Lim, Bo A;Kim, Seojin
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.311-320
    • /
    • 2013
  • The showcase has insufficient temperature control, but it has excellent humidity control. The annual average temperature and relative humidity inside the showcase was $18.8^{\circ}C$ and 60.3%, respectively, and the showcase showed lower temperature and higher humidity than the exhibition room. The temperature inside the showcase appeared with high variation according to the seasons, while relative humidity was ranging from 59% to 61% regardless of the seasons. The showcase showed high temperature and humidity likewise the exhibition room in summer. In addition, lowering of temperature was elevated relative humidity according to the operation of air conditioner in summer. A moisture problem occurred because the temperature and humidity differences between the exhibition room and showcase were large according to the operation of air conditioner in winter. PI for temperature and relative humidity inside the showcase is 18.0%, and it means conservation environment for exhibition is unsuitable. In particular, continuous management of temperature and humidity inside the showcase is required because PI in the summer and winter is less than 1.0%.

Dynamic Simulation of a Dedicated Outdoor Air-conditioning System (외기 전용 공조기의 동특성 시뮬레이션)

  • Kim, Jung-Min;Kim, Young-Il;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

A Study on the Influence of Climate Factors on Construction Accidents (기후요소가 건설안전사고에 미치는 영향에 관한 연구)

  • Son Chang-Baek;Kim Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.91-97
    • /
    • 2005
  • The purpose of this study is to provide basic data for establishment of prevention counterplan against construction accidents in preparation for variation of climate conditions. In order to execution of this study, it was analyzed relations of climate factors and cases of construction accident occurred construction sites. In occurrence of construction accidents inducing death upon variation of Climate factors, precipitation and wind velocity were not related directly to construction accidents inducing death. On the other hand, the more temperature and humidity are high, the more construction accidents inducing death occurred. Especially, when temperature and humidity are above $24^{\circ}C,\;70\%$ respectively, field managers must pay attention to safety management of construction sites.

An Experimental Study on the Effect of Temperature and Humidity on the Pressure Change of the Bootstrap type Reservoir in the Aircraft (자체여압 형 항공기용 저장조의 온도 및 습도에 따른 내부압력 변화에 관한 실험적 연구)

  • Kim, Jung-Sik;Yu, Han-Sik;Park, Dong-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.170-175
    • /
    • 2013
  • For this study, the domestically developed bootstrap reservoir of the aircraft is set up in accordance with the temperature and humidity conditions depicted on the qualification test, and the variation in the internal pressure of the bootstrap reservoir of the aircraft is examined. The study shows that the bootstrap reservoir has less variation in the internal pressure at room temperature than at low temperature($-40^{\circ}C$). As a result, the internal pressure can be maintained stably when the temperature of working fluid in the bootstrap reservoir and the atmosphere environment is over room temperature($25^{\circ}C$). Therefore the keeping of temperature above room temperature is very important to operate the bootstrap reservoir of the aircraft properly.

Electrical impedance-based crack detection of SFRC under varying environmental conditions

  • Kang, Man-Sung;An, Yun-Kyu;Kim, Dong-Joo
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • This study presents early crack detection of steel fiber-reinforced concrete (SFRC) under varying temperature and humidity conditions using an instantaneous electrical impedance acquisition system. SFRC has the self-sensing capability of electrical impedance without sensor installation thanks to the conductivity of embedded steel fibers, making it possible to effectively monitor cracks initiated in SFRC. However, the electrical impedance is often sensitively changed by environmental effects such as temperature and humidity variations. Thus, the extraction of only crack-induced feature from the measured impedance responses is a crucial issue for the purpose of structural health monitoring. In this study, the instantaneous electrical impedance acquisition system incorporated with SFRC is developed. Then, temperature, humidity and crack initiation effects on the impedance responses are experimentally investigated. Based on the impedance signal pattern observation, it is turned out that the temperature effect is more predominant than the crack initiation and humidity effects. Various crack steps are generated through bending tests, and the corresponding impedance damage indices are extracted by compensating the dominant temperature effect. The test results reveal that propagated cracks as well as early cracks are successfully detected under temperature and humidity variations.

The $CH_4$and $C_4$$H_{10}$ Sensitivity Measurement and Voltage Variation Using Catalytic Combustion Type Gas Sensor (접촉연소식 센서를 이용한 $CH_4$$C_4$$H_{10}$ 감도 측정 및 전압변화)

  • 윤헌주;신종열;홍진웅
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.44-48
    • /
    • 2001
  • In this study, we analyzed the $CH_4$and $C_4$$H_{10}$ sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. Gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 65 percent at a temperature of $20^{\circ}c$ and humidity of 85 percent at a temperature of $40^{\circ}c$. The gas detecter sensors are to be subjected to operation for 210 days in an area that has been determined to be equivalent to a typical residential atmosphere with an air velocity of 50 cm/sec. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a seperate source of supply direct applied voltage 2.1V, 2.2V, 2.3V. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the isobutane characteristic graph and methane characteristic graph by a relative humidity of 65% and 85% at a temperature($20^{\circ}c$, $40^{\circ}c$) show a similar linear pattern on the whore.

  • PDF

The Variations of Temperature and Humidity with the Insultor Materials in Wingtering Beehouse (단열재에 따른 저온양봉사 내부의 온.습도변화)

  • 이석건;김란숙;이현우;이종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.424-428
    • /
    • 1999
  • The simulation and experiments were conducted to anlayzed the vaiation of the temperature and humicity in the wintering beehouses which had two kinds of the insulator materials of urethane foam and sandwich panel individually . It was found that inside temperature of sandwich panel beehouse was similar to the urethane foam at the same outside temperature by the simulation results. The variation of the inside temperature and humidity for the urethane foam was less than the sandwich panel.

  • PDF

Humidity Dependence of Electrical Conductivity of Vacuum Evaporated Au Films on Glass (유리표면에 진공증착된 금박막의 전기전도도의 습도 의존성)

  • 이동영;박현수
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.6
    • /
    • pp.572-578
    • /
    • 1987
  • The vacuum evaporated Au films on soda-lime glasses were measured by the electrical conductivity with the variation of the annealing time, relative humidity, and temperature. Au films structures were observed by scanning Electron Microscope and X-ray Diffractometer. As the annealing time and temperature increased, the electrical conductivity was increased due to the migration or annihilation of defects, but the electrical conductivity was decreased as with the relative humidity increased. Au films by XRD and SEM examination showed the negligible effect of chemical reactions.

  • PDF

Dimensional Responses of Wood Under Cyclical Changing Temperature at Constant Relative Humidity

  • Yang, Tiantian;Ma, Erni;Shi, Yi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.539-547
    • /
    • 2015
  • To investigate dimensional responses of wood under dynamic temperature condition, poplar (populous euramericana Cv.) specimens, 20 mm in radial (R) and tangential (T) directions with two thicknesses of 4 and 10 mm along the grain, were exposed to cyclic temperature changes in square wave between $25^{\circ}C$ and $40^{\circ}C$ at 60% relative humidity (RH) for three different cycling periods of 6 h, 12 h and 24 h. R and T dimensional changes measured during the cycling gave the following results: 1) Transverse dimensional changes of the specimens were generally square but at an opposite phase and lagged behind the imposed temperature changes. The phase lag was inversely correlated with cycling period, but positively related to specimen thickness, while the response amplitude was directly proportional to cycling period, but in a negative correlation with specimen thickness. 2) The specimens showed swelling hysteresis behavior. The heat shrinkage coefficient (HSC) became greater as cycling period increased or specimen thickness decreased. 3) Dimensional changes of the specimens produced deformation accumulation during repeated adsorption and desorption. The deformation accumulating ratio decreased with an increase in cycling period and specimen thickness. 4) Wood suffered 1.5 times as many dimensional changes per unit temperature variation as per unit humidity variation, and this deformation behaved even more seriously under static condition.