• 제목/요약/키워드: temperature analysis

검색결과 19,344건 처리시간 0.042초

우리나라의 겨울철 기온 변화 및 한파 발생빈도 분석 (An Analysis of a Winter-time Temperature Change and an Extreme Cold Waves Frequency in Korea)

  • 전미정;조용성
    • 한국기후변화학회지
    • /
    • 제6권2호
    • /
    • pp.87-94
    • /
    • 2015
  • To compare changes in winter temperature over South Korea, 30-year average climate data and climate data of recent 10 years (2014~2014) such as mean temperature, daily maximum temperature and daily minimum temperature were analyzed. Also, we set analysis extreme cold waves frequency related to winter such as freezing days, snow days, days with temperature of below -5, and days with temperature of below -10. This process enabled the comparative analysis of winter temperature changes and extreme cold waves frequency related to winter. This study estimated that winter temperature has gradually increased throughout the last five decades, however, the frequency of extreme weather, such as cold waves has also increased.

Defrost nozzle의 토출 공기에 의한 승용차 실내 유동장 및 온도장 해석 (3-D Numerical analysis of flow and temperature field of automobile cabin by discharged air from defrost nozzle)

  • 강규태;박금성;박원규;장기룡
    • 한국전산유체공학회지
    • /
    • 제7권2호
    • /
    • pp.25-32
    • /
    • 2002
  • The velocity and temperature profiles in the cabin of the automobile affect greatly the comfortableness of passengers. In this paper, the three dimensional flow and temperature analysis in the cabin of real automobile have been peformed. The three dimensional Navier-Stokes equation solver was validated by comparing with the other numerical data of a 1/5 scale model. The temperature field of cavity was also analyzed for the validation of energy equation solver. After the code validation, the numerical analysis of real field of flow and temperature of an automobile was peformed and the present result provides the insight of flow and temperature field of the inside of cabin.

에폭시 경화물 DSC에 의한 유리전이 온도 측정의 분석조건 의존성 (The Effect of DSC Analysis Condition on the Glass Transition Temperature of curred Epoxy This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.)

  • 오무원;권혁삼
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.30-33
    • /
    • 1994
  • This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.

  • PDF

공원녹지의 토지피복비율과 기온간의 요인분석 (Factor Analysis of the Relation Between Land Cover Ratio of Green Spaces and Temperature)

  • 윤용한;박봉주;김원태;박선영
    • 한국환경과학회지
    • /
    • 제17권5호
    • /
    • pp.485-491
    • /
    • 2008
  • The present study examined the relation between land cover condition and temperature in various types of urban green spaces. The diagram of temperature distribution showed that high-temperature zones are formed around paved areas, and low temperature zone around planted areas and grassy areas. Even in planted areas where low-temperature zones were formed, temperature was different according to hierarchical structure. That is, temperature was relatively low in areas covered with arbor + sub-arbor. With regard to land cover ratio, the increase of planted areas and grassy areas had an effect on the fall of temperature and the effect was higher in order of planted areas and grassy areas. On the contrary, paved areas and bare areas had an effect on the rise of temperature. According to the results of factor analysis, in case of the highest temperature, planted area and grassy area were put together into a factor lowering temperature, paved area and temperature into a factor raising temperature, and bare area alone into a factor of low significance. In case of the lowest temperature, grassy area and bare area were put together into a factor, and the validity of the factor analysis was proved by the analysis of urban heat islands. An increase in the number of trees by height was effective in lowering temperature, and the effect was high in order to arbor and sub-arbor, and the source of coldness in planted area was tall trees.

FVM과 반무한체 해석을 이용한 표면온도예측에 관한 연구 (A Study for Estimation of the Surface Temperature Rise Using the FVM and Semi-Infinite Solid Analysis)

  • 김태완;이상돈;조용주
    • Tribology and Lubricants
    • /
    • 제18권6호
    • /
    • pp.389-395
    • /
    • 2002
  • The surface temperature at the interface of bodies in a sliding contact is one of the most important factors influencing the behavior of machine components. The calculation of the surface temperature at a sliding contact interface has been an interesting and important subject for tribologist. Temperature analyses were usually performed under the consideration contacted two bodies as semi-infinite. But the analysis was difficulty in being applied to finite body and considering the boundary condition. In this study, contact temperature rise of two finite bodies and surfaces due to frictional heating under the rectangular and the circular sliding contact is calculated. Heat partition factor is calculated using semi-infinite solid analysis and the temperature of the finite bodies is calculated using FVM. It will be shown that Most frictional heat in the fore part of contact region for sliding direction is conducted into body that has a moving heat source and the site of the maximum temperature rise moves to the opposite direction of sliding during sliding.

강판 종별 온도에 따른 산화 민감도 조사 (Investigation of Oxidation Sensitivity with Temperature of Steel Plate Type)

  • 김주한;이기만
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.455-464
    • /
    • 2019
  • Experiments were conducted to investigate the sensitivity of steel plate oxidation with temperature in a simulated furnace. Used steel plates were a general steel and a high tensile steel. Porous media burner (PM burner) used in model furnace was made for uniform temperature profile. The surrounding temperature was controlled by adjusting the flow rate of the mixture in the combustor. Oxide layer analysis was performed using SEM image analysis and EDS line scanning. Both steel sheets showed a tendency to increase the thickness of the steel sheet surface oxide layer as the temperature increases, and it was confirmed that the flaking phenomenon in surface oxidation layer appeared when the temperature was above a certain temperature.

기후변화와 건강 - 저온과 고온이 사망에 미치는 영향에 관한 체계적 고찰 (Climate Change and Health - A Systemic Review of Low and High Temperature Effects on Mortality)

  • 임연희;김호
    • 한국환경보건학회지
    • /
    • 제37권6호
    • /
    • pp.397-405
    • /
    • 2011
  • Objectives: The impact of climate change on the health has been of increasing concern due to a recent temperature increase and weather abnormality, and the research results of the impact varied depending on regions. We synthesized risk estimates of the overall health effects of low and high temperature taking account of the heterogeneity. Methods: A comprehensive literature search was conducted using PUBMED to identify journal articles of low and/or high temperature effects on mortality. The search was limited to the English language and epidemiological studies using time-series analysis and/or case-crossover design. Random-effect models in meta analysis were used to estimate the percent increase in mortality with $1^{\circ}C$ temperature decrease or increase with 95% confidence intervals (CI) in cold or hot days. Results: Twenty three studies were presented in two tables: 1) low temperature effects; 2) high temperature effects on mortality. The combined effects of low and high temperatures on total mortality were 2% (95% CI, 1-4%) per $1^{\circ}C$ decrease and 4% (95% CI, 2-5%) per $1^{\circ}C$ increase of temperature, respectively. Conclusions: This meta analysis found that both low and high temperatures affected mortality, and the magnitude of high temperature appeared to be stronger than that of low temperature.

표층화분의 WA-PLS 분석을 통한 한반도 남동부지역 홀로세 고기온 복원 (Reconstruction of Paleo-Temperature During the Holocene Using WA-PLS Analysis of Modern Pollen From the Surface Soil in the Southeastern Part of the Korean Peninsula)

  • 윤순옥;황범진;황상일
    • 한국지형학회지
    • /
    • 제24권4호
    • /
    • pp.13-25
    • /
    • 2017
  • To reconstruct the paleo-temperature quantitatively and to overcome limitation of traditional qualitative pollen analysis, this study was performed pollen analysis using the modern surface soil at Yulha-dong, Gimhae-si of southeastern part of Korean peninsula. Canonical Correspondence Analysis(CCA) was done to identify the most important environment variable about composition of modern surface pollen sample. Also, Weighted Average-Partial Least Square(WA-PLS) was analyzed to obtain modern surface pollen-temperature transfer function. The transfer function was applied to the results of qualitative fossil pollen analysis at Yulha-dong, Gimhae-si, Sampyung-ri, Ulsan-si and Taewha-dong, Ulsan-si. Therefore, the paleo-temperature was reconstructed during the Holocene since 6,200 yr BP. According to the results of the research, it is $1{\sim}2^{\circ}C$ lower than the current average annual temperature at the study area in 6,200 yr BP, since then it increased to the same level to the current temperature and decreased again until 2,600 yr BP. From the 2,600 yr BP, the temperature was fluctuated to the present.

측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석 (Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position)

  • 이충근;신항식
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

해석적 기법을 이용한 초고압 GIS용 삼상모선의 온도분포 해석 (Analysis of Temperature Distribution in EHV GIS Three-Phase Busbar Using Analytic Technique)

  • 한성진;김중경
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권4호
    • /
    • pp.196-202
    • /
    • 2006
  • This paper presents a new magneto-thermal finite element analysis for predicting the temperature rise of the EHV GIS busbar. Joule's heat due to current flowing in the main conductor and the heat due to the induced eddy current in the tank are calculated by the magnetic field analysis. And these heats are used as the input data to predict the temperature rise for the thermal analysis. However, it is not easy to apply the heat-transfer coefficients on the boundaries for the thermal analysis. In this paper, the heat-transfer coefficients on the boundaries are analytically calculated by applying the Nusselt number considering material constant and model geometry for the natural convection. The temperature distribution in the busbar by coupled magneto-thermal finite element analysis shows good agreement with the experimental data.