• 제목/요약/키워드: temperature distribution

검색결과 7,464건 처리시간 0.038초

접선 연소식 보일러의 최종 과열기 열부하 분포 및 튜브 온도 예측에 관한 연구 (Prediction of Thermal Load Distribution and Temperature of the Superheater in a Tangentially Fired Boiler)

  • 박호영;서상일
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.478-485
    • /
    • 2008
  • The extreme steam temperature deviation experienced in the superheater of a tangentially fired boiler can seriously affect its economic and safe operation. This temperature deviation is one of the main causes of boiler tube failures. The steam temperature deviation is mainly due to the thermal load deviation in the lateral direction of the superheater. The thermal load deviation consists of several causes. One of the causes is the non-uniform heat flow distribution of burnt gas on the superheater tube system. This distribution is very difficult to measure in situ using direct experimental techniques. So, we need thermal load model to estimate the tube temperature. In this paper, we propose a thermal load distribution model by using CFD analysis and plant data. We successfully predict the tube temperature and the steam flow rate in a final superheater system from the thermal load model and one dimensional heat-flow system analysis. The proposed model and analysis method would be valuable in preventing the frequent tube failure of the final superheater tubes.

Off-Axis 디지털홀로그래피를 이용한 마이크로히터의 실시간 온도분포측정 (Real Time Temperature Distribution Measurement of a Microheater by Using Off-Axis Digital Holography)

  • 체랭돌가르;백병준;김대석
    • 한국진공학회지
    • /
    • 제20권2호
    • /
    • pp.106-113
    • /
    • 2011
  • 본 논문은 마이크로히터표면의 실시간 온도분표측정을 위한 마하젠더 간섭계 기반의 off-axis 디지털홀로그래피기술에 대한 것이다. 제안된 방법은 재료표면의 온도분포에 직접적인 함수인 2차원 위상 분포를 측정하고, 이를 통해 실시간으로 재료표면의 온도 map을 측정할 수 있다. 본 논문에서는 섭씨 20도에서 60도 사이의 온도구간에서 마이크로히터 표면의 위상변화와 실제표면온도가 선형적인 관계가 있음을 실험적으로 보였다. 제안된 방법은 재료표면의 온도분포를 실시간으로 측정하고자 하는 다양한 응용분야에 적용될 수 있을 것으로 기대된다.

A Study on Thermal Performance of Heat Pipe for Optimum Placement of Satellite Equipment

  • Park, Jong-Heung
    • ETRI Journal
    • /
    • 제19권2호
    • /
    • pp.59-70
    • /
    • 1997
  • A study on the operation of a heat pipe with two heat sources has been performed to optimize the heat distribution of satellite equipment. A numerical modeling is used to predict the temperature profile for the heat pipe assuming cylindrical two-dimensional laminar flow for the vapor, and the conduction heat transfer for the wall and wick. An experimental study using the copper-water heat pipe with the length of 0.45 m has been performed to evaluate the numerical model and to compare the temperature distribution at the outer wall for the non-uniform heat distribution. The results on temperature profiles for the heat input range from 29 W to 47 W on each heater are presented. Also the correlation between the heat input and the temperature increase is presented for the optimum distribution on two heaters. The result shows that the outer wall temperature can be controlled by redistribution of heat sources. It is also concluded that the heat source closer to the condenser can carry more heat while maintaining lower temperatures at the outer wall.

  • PDF

PIC 렌즈 전조등 렌즈면의 온도분포에 관한 실험적 연구 (An Experimental Study on the Lens Surface Temperature Distribution of P/C Headlamp Using the Three Category of H4 Halogen Bulbs)

  • 박경석;강병도
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.158-165
    • /
    • 2002
  • This Paper deals with the headlamp lens surface temperature distribution of p/c headlamp using the three categories of H4 halogen bulbs. Glass is gradually replaced by P/C for the lens material off vehicle headlamp due to the weight reduction and stream lined body of a vehicle. With this trend, the newly established standards for a headlamp with a P/C lens in Europe requires that the heat generated by a bulb should not distort the lens surface. Also the requirements fur the bulb of a headlamp are being enforced in U.S.A & Europe. However, such requirements are not established yet in Korea. By using three kinds (60/55w, 100/90w, 130/90w) of H4 halogen bulbs in this experiment, the surface temperature distribution and Max. temperature on the lens were measured. The results of this study implies the necessity of requirement fur the bulb off headlamp.

전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화 (NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE)

  • 이수윤;안준;신승원
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.1-8
    • /
    • 2009
  • Diverging channel from gas engine exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B), two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of the boiler(Case C) and uniformity in velocity and temperature distribution has been improved considerably. Secondly, the diverging channel length can be further reduced to compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화 (Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser)

  • 조지용;김중경
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

Time-dependent Optimal Heater Control in Thermoforming Preheating Using Dual Optimization Steps

  • Li, Zhen-Zhe;Heo, Kwang-Su;Seol, Seoung-Yun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.51-56
    • /
    • 2008
  • Thermoforming is one of the most versatile and economical processes available for shaping polymer products, but obtaining a uniform thickness of the final product using this method is difficult. Heater power adjustment is very important because the thickness distribution depends strongly on the distribution of the sheet temperature. In this paper, the steady-state optimum distribution of heater power is first ascertained by a numerical optimization to obtain a uniform sheet temperature. The time-dependent optimal heater input is then determined to decrease the temperature difference through the direction of the thickness using the response surface method and the D-optimal method. The optimal results show that the time-dependent optimum heater power distribution gives an acceptable uniform sheet temperature in the forming temperature range by the end of the heating process.

Distribution of Cathodic Protection Potential for Concrete Slab Specimens at Diverse Environmental Conditions

  • Jin, Chung-Kuk;Jeong, Jin-A
    • International Journal of Ocean System Engineering
    • /
    • 제3권2호
    • /
    • pp.90-94
    • /
    • 2013
  • This study represents the recent laboratory results from cathodic protection (CP) system with the use of sacrificial anodes at different environmental conditions (temperature of $10^{\circ}C$ and $40^{\circ}C$). Specimens were slab type with a dimension of $500mm{\times}50mm{\times}100mm$, and concrete cover thickness were 25mm. Zinc mesh and/or bulk type anodes were installed at the center of specimen to confirm the distance that CP system has influences on the specimen to distribute uniform CP current to rebar. Two different kinds of temperature condition were applied to verify the effect of temperature. Experiments were conducted for 60 days, and the distribution of potential and current that supplied from anode to rebar was measured. From the results, CP potential was varied with time, and temperature played an important role in CP potential variations. Current was also changed with time, and current distribution could be improved by installing additional bulk type anode.

The Determination of Stress Distribution in WC-Ni Cemented Carbide Composites by Neutron Diffraction

  • Seol, Kyeongwon
    • 한국재료학회지
    • /
    • 제5권2호
    • /
    • pp.232-238
    • /
    • 1995
  • The thermal stress distribution of WC and Ni binder phases In WC-26st.%Ni and WC-6wt.%Ni composites has been investigated over the temperature range 100-900 K using a time-of-flight neutron diffractometer. To determine the stress distribution, the breadths of WC and Ni peaks in the reference powder and the composites were analyzed. The peak breadths were corrected for particle size effect using a procedure based on the integral peak breadth method of particle size-strain analysis. The result shows a broad range of strain, and thus stress, is present in the WC and Ni binder phases of the composites. The strain distribution of both phases broadens as the temperature decreases, and some fraction of total strain distribution of the WC phase remains tensile regardless of the temperature. The strain distribution of the WC phase broadens as the binder content increases, and that of Ni binder phase broadens as the binder content decreases, which means the strain distribution broadens as the absolute value of residual stress increase.

  • PDF

광 조사에 따른 온도분포를 이용한 생체조직 내 비정상조직 탐지에 대한 연구 (A Study on the Detection of Abnormal Tissues in Biological Tissue Using Temperature Distribution According to Light Irradiation)

  • 고동국;임익태
    • 대한기계학회논문집B
    • /
    • 제41권5호
    • /
    • pp.303-309
    • /
    • 2017
  • 본 연구에서는 비정상조직(파라핀)을 가진 생체조직에 광을 조사하고 그에 따른 조직의 표면온도와 비정상조직 주위에서의 온도분포를 실험과 해석적 방법을 통해 분석하였다. 파라핀을 이용하여 비정상 조직을 모사한 후 조사하는 광의 파장과 시간을 변화시키면서 조직 주위에서의 온도를 K형 열전대를 사용하여 측정하였다. 또한 전산열전달 기법을 이용하여 해석적으로 조직에 대한 온도분포를 예측하였다. 정상조직과 비정상조직의 주위에서의 온도는 차이가 있었으며, 비정상조직이 있는 경우 표면과 조직 주위의 온도가 높게 나타났다.