• Title/Summary/Keyword: television monitoring

Search Result 117, Processing Time 0.023 seconds

SHM benchmark for high-rise structures: a reduced-order finite element model and field measurement data

  • Ni, Y.Q.;Xia, Y.;Lin, W.;Chen, W.H.;Ko, J.M.
    • Smart Structures and Systems
    • /
    • v.10 no.4_5
    • /
    • pp.411-426
    • /
    • 2012
  • The Canton Tower (formerly named Guangzhou New TV Tower) of 610 m high has been instrumented with a long-term structural health monitoring (SHM) system consisting of over 700 sensors of sixteen types. Under the auspices of the Asian-Pacific Network of Centers for Research in Smart Structures Technology (ANCRiSST), an SHM benchmark problem for high-rise structures has been developed by taking the instrumented Canton Tower as a host structure. This benchmark problem aims to provide an international platform for direct comparison of various SHM-related methodologies and algorithms with the use of real-world monitoring data from a large-scale structure, and to narrow the gap that currently exists between the research and the practice of SHM. This paper first briefs the SHM system deployed on the Canton Tower, and the development of an elaborate three-dimensional (3D) full-scale finite element model (FEM) and the validation of the model using the measured modal data of the structure. In succession comes the formulation of an equivalent reduced-order FEM which is developed specifically for the benchmark study. The reduced-order FEM, which comprises 37 beam elements and a total of 185 degrees-of-freedom (DOFs), has been elaborately tuned to coincide well with the full-scale FEM in terms of both modal frequencies and mode shapes. The field measurement data (including those obtained from 20 accelerometers, one anemometer and one temperature sensor) from the Canton Tower, which are available for the benchmark study, are subsequently presented together with a description of the sensor deployment locations and the sensor specifications.

A Study on Electric Power Monitoring System per Appliance (기기별 전력 모니터링 시스템 개발에 관한 연구)

  • Park, Sung-Wook;Kim, Jong-Shick;Lim, Su-Jin;HwangBo, Sea-Hee;Son, Joon-Ik;Lee, In-Yong;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • This paper presents ideas of service scenarios for home residents using electric power monitoring system per appliance, the implementation of the monitoring system, and analysis of acquired electric power usage pattern. By acquiring and analyzing electric power usage pattern, home residents can get information of power usage pattern of every legacy (non-Demand Response-ready) appliance. Further they can get pieces of recommendation how to reduce energy consumption, intelligent standby power blocking service, and alarming service to abnormality of appliances. In order to check the feasibility of the ideas, a system that can acquire electric power pattern per appliance is implemented, and electric power pattern of some appliances are stored to a database and it was analyzed to show if auto-identification of a type of a device is possible, which is a basic required function for the scenarios presented.

Reducing Standby Power Consumption System by Monitoring the AC Input Current for the AV Devices (AV 기기를 위한 AC 입력 전류 모니터링 대기 전력 저감 시스템)

  • Lee, Dae Sik;Yi, Kang Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1493-1496
    • /
    • 2016
  • This paper proposes a system for reducing the standby power consumption in using the consumer electronic devices such as a television, a home theater, a set-top box, or a DVD player. The system is consisted of a flyback converter, monitoring circuits, a relay and a micro-processor. The proposed system can reduce the standby power consumption by disconnecting the AC input and the consumer devices can be turned on with a remote control. The proposed standby power system consumes the low power to receive the infrared signal from the remote controller. Furthermore, a electronic double layer capacitor is used to store the energy with high efficiency. The proposed power system can operate the 플라이백 converter to charge the electronic double layer capacitor and connect the AC input to the consumer electronic devices. The proposed power circuit can reduce the standby power consumption in AV devices without increasing the cost. The prototype is implemented to verify the system with the commercialized products.

System identification of a super high-rise building via a stochastic subspace approach

  • Faravelli, Lucia;Ubertini, Filippo;Fuggini, Clemente
    • Smart Structures and Systems
    • /
    • v.7 no.2
    • /
    • pp.133-152
    • /
    • 2011
  • System identification is a fundamental step towards the application of structural health monitoring and damage detection techniques. On this respect, the development of evolved identification strategies is a priority for obtaining reliable and repeatable baseline modal parameters of an undamaged structure to be adopted as references for future structural health assessments. The paper presents the identification of the modal parameters of the Guangzhou New Television Tower, China, using a data-driven stochastic subspace identification (SSI-data) approach complemented with an appropriate automatic mode selection strategy which proved to be successful in previous literature studies. This well-known approach is based on a clustering technique which is adopted to discriminate structural modes from spurious noise ones. The method is applied to the acceleration measurements made available within the task I of the ANCRiSST benchmark problem, which cover 24 hours of continuous monitoring of the structural response under ambient excitation. These records are then subdivided into a convenient number of data sets and the variability of modal parameter estimates with ambient temperature and mean wind velocity are pointed out. Both 10 minutes and 1 hour long records are considered for this purpose. A comparison with finite element model predictions is finally carried out, using the structural matrices provided within the benchmark, in order to check that all the structural modes contained in the considered frequency interval are effectively identified via SSI-data.

A study on operation efficacy and security improvement through structural modification of CCTV network for bansong water purification plant (반송정수장 CCTV망의 구조개선을 통한 운영효율화 및 보안성 개선사례에 관한 연구)

  • Park, Yeunchul;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.193-200
    • /
    • 2018
  • Owing to the development in information and communications technologies have improved the technology for high-speed transmission of massive data, which has changed closed-circuit television (CCTV) video transmission technology. In particular, digitization of the CCTV video format and streaming technology has made it possible to minimize transmission loss and integrate video transmission and camera control(pan/tilt). It has also become possible to provide additional services like remote emergency warning broadcasting with just Internet Protocol (IP). However, because of the structural problems of IP, these changes have also brought about the threat of hacking of CCTV monitoring systems. In this study, we propose a methode to optimize network management by examining cases of enhancement of operational efficiency and security by improving the structure of CCTV monitoring network.

Social Worker's Image Perceived by Middle and High School Students -Comparison of the Image of Social Worker and Nurse- (중·고등학생들이 지각하는 사회복지사 이미지에 관한 연구 -사회복지사와 간호사 이미지 비교를 중심으로-)

  • Lee, Kyung Cheol;Kim, Yu-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.528-536
    • /
    • 2016
  • The aim of this study was to understand the difference between the image of social-workers and nurses perceived by middle school and high school students, and determine the experience related to social workers and the role of social workers projected in the media. The subjects of this study were 386 students of middle and high school located in S city. Data were collected from Oct. 15, 2013 to Nov. 23, 2013 and analyzed using the SPSS win 18.0 program. A comparison of the image of nurses and social workers in two groups showed that middle school students tended to have a more positive image of nurses than high school students, and the image of nurses appeared to be more positive than that of social workers. As a result of analyzing the contents exposed in media, the students received most of their information on social workers from TV. Therefore, it is necessary to have a strategy to help students choose a major or a job by reinforcing mass media monitoring based on TV, which may have a major impact on the image of social workers and provide them with the correct information on the profession.

Network vision of disaster prevention management for seashore reclaimed u-City (해안매립 신도시의 재해 예방관리 네트워크 비젼)

  • Ahn, Sang-Ro
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.117-129
    • /
    • 2009
  • This paper studied the safety management network system of infrastructure which constructed smart sensors, closed-circuit television(CCTV) and monitoring system. This safety management of infrastructure applied to bridge, cut slop and tunnel, embankment etc. The system applied to technologies of standardization guidelines, data acquirement technologies, data analysis and judgment technologies, system integration setup technology, and IT technologies. It was constructed safety management network system of various infrastructure to improve efficient management and operation for many infrastructure. Integrated safety management network system of infrastructure consisted of the real-time structural health monitoring system of each infrastructure, integrated control center, measured data transmission using i of tet web-based, collecting data using sf ver, early alarm system which the dangerous event of infrastructure occurred. Integrated control center consisted of conference room, control room to manage and analysis the data, server room to present the measured data and to collect the raw data. Early alarm system proposed realization of warning and response within 5 minute or less through development of sensor-based progress report and propagation automation system using the media such as MMS, VMS, EMS, FMS, SMS and web services of report and propagation. Based on this, the most effective u-Infrastructure Safety Management System is expected to be stably established at a less cost, thus making people's life more comfortable. Information obtained from such systems could be useful for maintenance or structural safety evaluation of existing structures, rapid evaluation of conditions of damaged structures after an earthquake, estimation of residual life of structures, repair and retrofitting of structures, maintenance, management or rehabilitation of historical structures.

  • PDF

A Snoop-Based Kernel Introspection System against Address Translation Redirection Attack (메모리 주소 변환 공격을 탐지하기 위한 Snoop기반의 커널 검사 시스템)

  • Kim, Donguk;Kim, Jihoon;Park, Jinbum;Kim, Jinmok
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.5
    • /
    • pp.1151-1160
    • /
    • 2016
  • A TrustZone-based rootkit detecting solution using a secure timer ensures the integrity of monitoring system, because ARM TrustZone technology provides isolated environments from a monitored OS against intercepting and modifying invoke commands. However, it is vulnerable to transient attack due to periodic monitoring. Also, Address Translation Redirection Attack (ATRA) cannot be detected, because the monitoring is operated by using the physical address of memory. To ameliorate this problem, we propose a snoop-based kernel introspection system. The proposed system can monitor a kernel memory in real-time by using a snooper, and detect memory-bound ATRA by introspecting kernel pages every context switch of processes. Experimental results show that the proposed system successfully protects the kernel memory without incurring any significant performance penalty in run-time.

Response of Bioluminescent Bacteria to Sixteen Azo Dyes

  • Lee, Hwa-Young;Park, Sue-Hyung;Gu, Man-Bock
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.101-105
    • /
    • 2003
  • Recombinant bioluminescent bacteria were used to monitor and classify the to xicity of azo dyes. Two constitutive bioluminescent bacteria, Photobacterium phosphoreum and Es-Cherichia coli, E, coli GC2 (lac::luxCOABE), were used to detect the cellular toxicity of the azo dyes. In addition, four stress-inducible bioluminestent E. coli, DPD2794 (recA::luxCDABE), a DNA damage Sensitive strain; DPD2540 (fabA::luxCDABE), a membrane damage sensitive strain; DPD2511 (katG::luxCDABE), an oxidative damage sensitive strain; and TV1061 (grpE::luxCDABE), a protein damage sensitive strain, were used to provide information about the type of toxicity caused by crystal violet, the most toxic dye of the 16 azo dyes tested. These results suggest that azo dyes result in serious cellular toxicity in bacteria, and that toxicity monitoring and classific ation of some azo dyes, In the field, may be possible using these recombinant bioluminescent bacteria.

A Study on Passenger Information Integrated System Based IP (IP 기반의 승객안내 통합시스템에 대한 고찰)

  • Kwon, Myoung-Jin;Jeon, Yoon-Su;Lee, Chan-Yong;Park, Sung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1716-1721
    • /
    • 2011
  • The Public Address and Passenger Information System of Rolling Stock should be able to perform automatic announcements in connection with TCMS(Train Control and Monitoring System), common announcements and emergency announcements for safe operation and the passengers. CCTV(Closed Circuit Television) System also should be able to watch passenger compartment for safety. Those equipments are very important thing for train service and safety. but the installation of equipment is restricted by space, weight, modulation. therefore, Passenger Information Intergrated System(PIIS) is required to consider economical efficiency, technical trend, expansion and space insufficiency. and system based on IP network has to be considered as new PIIS. so PIIS could meet economical efficiency and expansion. and it could go further and share network with TCMS and others.

  • PDF