Browse > Article
http://dx.doi.org/10.12989/sss.2012.10.4_5.411

SHM benchmark for high-rise structures: a reduced-order finite element model and field measurement data  

Ni, Y.Q. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
Xia, Y. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
Lin, W. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
Chen, W.H. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
Ko, J.M. (Department of Civil and Structural Engineering, The Hong Kong Polytechnic University)
Publication Information
Smart Structures and Systems / v.10, no.4_5, 2012 , pp. 411-426 More about this Journal
Abstract
The Canton Tower (formerly named Guangzhou New TV Tower) of 610 m high has been instrumented with a long-term structural health monitoring (SHM) system consisting of over 700 sensors of sixteen types. Under the auspices of the Asian-Pacific Network of Centers for Research in Smart Structures Technology (ANCRiSST), an SHM benchmark problem for high-rise structures has been developed by taking the instrumented Canton Tower as a host structure. This benchmark problem aims to provide an international platform for direct comparison of various SHM-related methodologies and algorithms with the use of real-world monitoring data from a large-scale structure, and to narrow the gap that currently exists between the research and the practice of SHM. This paper first briefs the SHM system deployed on the Canton Tower, and the development of an elaborate three-dimensional (3D) full-scale finite element model (FEM) and the validation of the model using the measured modal data of the structure. In succession comes the formulation of an equivalent reduced-order FEM which is developed specifically for the benchmark study. The reduced-order FEM, which comprises 37 beam elements and a total of 185 degrees-of-freedom (DOFs), has been elaborately tuned to coincide well with the full-scale FEM in terms of both modal frequencies and mode shapes. The field measurement data (including those obtained from 20 accelerometers, one anemometer and one temperature sensor) from the Canton Tower, which are available for the benchmark study, are subsequently presented together with a description of the sensor deployment locations and the sensor specifications.
Keywords
structural health monitoring; benchmark problem; high-rise structure; finite element model; field monitoring data;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Adewuyi, A.P., Wu, Z.S. and Serker, N.H.M.K. (2009), "Assessment of vibration-based damage identification methods using displacement and distributed strain measurements", Struct. Health Monit., 8, 443-461.   DOI
2 Aktan, A.E., Chase, S., Inman, D. and Pines, D.D. (2001), "Monitoring and managing the health of infrastructure systems", in: Health Monitoring and Management of Civil Infrastructure Systems, (Eds. Chase, S.B. and Aktan, A.E.), Proceedings of the SPIE Vol. 4337, SPIE, Bellingham, Washington, USA (CD-ROM).
3 Brownjohn, J.M.W. (2007), "Structural health monitoring of civil infrastructure", Philos. T. R. Soc. A., 365(1851), 589-622.   DOI   ScienceOn
4 Carden, E.P. and Fanning, P. (2004), "Vibration based condition monitoring: a review", Struct. Health Monit., 3(4), 355-377.   DOI   ScienceOn
5 Catbas, F.N. and Aktan, A.E. (2002), "Condition and damage assessment: issues and some promising indices", J. Struct. Eng.- ASCE, 128(8), 1026-1036.   DOI   ScienceOn
6 Chang, P.C., Flatau, A. and Liu, S.C. (2003), "Health monitoring of civil infrastructure", Struct. Health Monit., 2, 257-267.   DOI   ScienceOn
7 DeWolf, J.T., Lauzon, R.G. and Culmo, M.P. (2002), "Monitoring bridge performance", Struct. Health Monit., 1(2), 129-138.   DOI   ScienceOn
8 Doebling, S.W., Farrar, C.R. and Prime, M.B. (1998), "A summary review of vibration-based damage identification methods", Shock Vib., 30, 91-105.   DOI   ScienceOn
9 Fujino, Y., Siringoringo, D.M. and Abe, M. (2009), "The needs for advanced sensor technologies in risk assessment of civil infrastructures", Smart Struct. Syst., 5(2), 173-191.   DOI
10 Glisic, B., Inaudi, D. and Casanova, N. (2009), "SHM process lessons learned in 250 SHM projects", in: Proceedings of the 4th International Conference on Structural Health Monitoring and Intelligent Infrastructure, Zurich, Switzerland (CD-ROM).
11 Gorl, E. and Link, M. (2003), "Damage identification using changes of eigenfrequencies and mode shapes", Mech. Syst. Signal Pr., 17(1), 103-110.   DOI   ScienceOn
12 Hao, H. and Xia, Y. (2002), "Vibration-based damage detection of structures by genetic algorithm", J. Comput. Civil Eng., 16(3), 222-229.   DOI   ScienceOn
13 Ko, J.M. and Ni, Y.Q. (2005), "Technology developments in structural health monitoring of large-scale bridges", Eng. Struct., 27(12), 1715-1725.   DOI   ScienceOn
14 Lu, Z.R. and Law, S.S. (2007), "Features of dynamic response sensitivity and its application in damage detection", J. Sound Vib., 303(1-2), 305-329.   DOI   ScienceOn
15 Ni, Y.Q., Wong, K.Y. and Xia, Y. (2011), "Health checks through landmark bridges to sky-high structures", Adv. Struct. Eng., 14(1), 103-119.   DOI   ScienceOn
16 Sohn, H., Farrar, C.R., Hemez, F.M., Shunk, D.D., Stinemates, D.W., Nadler, B.R. and Czarnecki, J.J. (2004), A review of structural health monitoring literature: 1996-2001, Los Alamos National Laboratory, Report LA-13976-MS, Los Alamos, USA.
17 Ni, Y.Q., Xia, Y., Liao, W.Y. and Ko, J.M. (2009), "Technology innovation in developing the structural health monitoring system for Guangzhou New TV Tower", Struct. Control Health Monit., 16(1), 73-98.   DOI   ScienceOn
18 Ou, J. and Li, H. (2009), Structural health monitoring research in China: trends and applications, in: Structural Health Monitoring of Civil Infrastructure Systems, (Eds., Karbhari, V.M. and Ansari, F.), Woodhead Publishing, Cambridge, UK, 463-516.
19 Rolander, D.D., Phares, B.M., Graybeal, B.A., Moore, M.E. and Washer, G.A. (2001), "Highway bridge inspection: state-of-the-practice survey", Transport. Res. Record, 1749, 73-81.   DOI
20 Wang, M.L. and Yim, J. (2010), "Sensor enriched infrastructure system", Smart Struct. Syst., 6(3), 309-333.   DOI
21 Wong, K.Y. (2004), "Instrumentation and health monitoring of cable-supported bridges", Struct. Control Health Monit., 11(2), 91-124.   DOI   ScienceOn
22 Xia, Y., Ni, Y.Q., Zhang, P, Liao, W.Y. and Ko, J.M. (2011), "Stress development of a super-tall structure during construction: field monitoring and numerical analysis", Comput. Aided Civil Infrastruct. Eng., 26(7), 542-559.   DOI   ScienceOn
23 Yun, C.B., Lee, J.J. and Koo, K.Y. (2011), "Smart structure technologies for civil infrastructures in Korea: recent research and applications", Struct. Infrastruct. Eng., 7(9), 673-688.   DOI   ScienceOn