• Title/Summary/Keyword: tee junction

Search Result 9, Processing Time 0.024 seconds

Development of Optimal Design User Interface for Waveguide tee Junction using PSO Algorithm and VBA (PSO 알고리즘과 VBA를 이용한 Waveguide tee Junction의 최적설계 인터페이스 개발)

  • Park, Hyun-Soo;Byun, Jin-Kyu;Lee, Dal-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.36-39
    • /
    • 2009
  • We developed an optimal design interface based on VBA(Visual Basic Application) that takes advantage of API(Application Program Interface) function of commonly used EM analysis software. The developed interface is adopted for an optimal design of a septum in a waveguide tee junction using PSO(Particle Swarm Optimization) algorithm. The objective function of the optimal design is defined by $S_{11}$-parameter of the waveguide tee junction Design variables are established as position of the septum, that are changed to satisfy the design goal Using the developed design interface and PSO algorithm, the objective function converged to the smallest value, showing the validity of the proposed method. The design interface was developed using Microsoft Excel software, enabling easy control of design parameters for user. Also, various analysis parameters can be set in the Excel interface, including waveguide input mode and frequency. After completion of the design, field solutions at user-specified positrons can be extracted to the output files in complex number form.

  • PDF

Numerical Simulation of Thermal Fluctuation of Hot and Cold Fluids Mixing in a Tee Junction

  • Gao, Kai;Lu, Tao
    • International Journal of Advanced Culture Technology
    • /
    • v.3 no.2
    • /
    • pp.171-178
    • /
    • 2015
  • In this work, mixing processes of hot and cold fluids of three different jet types are predicted by large-eddy simulation (LES) on FLUENT platform. Temperature at different positions of internal wall and mixing conditions of T-junctions at different times are obtained, then the simulated normalized mean and root-mean square (RMS) temperature, temperature contour and velocity vector of every case are compared. The results indicate that, the mixing regions in the tee junction is related to the jet type, and temperature fluctuations on the pipe wall in the type of the deflecting jet is the least.

Assessment of Fatigue and Fracture on a Tee-Junction of LMFBR Piping Under Thermal Striping Phenomenon

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Bong Yoo
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.267-275
    • /
    • 1999
  • This paper deals with the industrial problem of thermal striping damage on the French prototype fast breeder reactor, Phenix and it was studied in coordination with the research program of IAEA. The thermomechanical and fracture mechanics evaluation procedure of thermal striping damage on the tee-junction of the secondary piping using Green's function method and standard FEM is presented. The thermohydraulic(T/H) loading condition used in the present analysis is the random type thermal loads computed by T/H analysis on the turbulent mixing of the two flows with different temperatures. The thermomechanical fatigue damage was evaluated according to ASME code section 111 subsection NH. The results of the fatigue analysis showed that fatigue failure would occur at the welded joint within 90,000 hours of operation. The assessment for the fracture behavior of the welded joint showed that the crack would be initiated at an early stage in the operation. It took 42,698.9 hours for the crack to propagate up to 5 mm along the thickness direction. After then, however, the instability analysis, using tearing modulus, showed that the crack would be arrested, which was in agreement with the actual observation of the crack. An efficient analysis procedure using Green's function approach for the crack propagation problem under random type load was proposed in this study. The analysis results showed good agreement with those of the practical observations.

  • PDF

Applicability Evaluation of Methodology for Evaluating High Cycle Thermal Fatigue of a Mixing Tee in Nuclear Power Plants (원전 혼합배관 고주기 열피로 평가방법론의 적용성 평가)

  • Kim, Sun-Hye;Sung, Hee-Dong;Choi, Jae-Boong;Huh, Nam-Su;Park, Jeong-Soon;Choi, Young-Hwan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.44-50
    • /
    • 2011
  • Turbulent mixing of hot and cold coolants is one of the possible causes of high cycle thermal fatigue in piping systems of nuclear power plants. A typical situation for such mixing appears in turbulent flow through a T-junction. Since the high cycle thermal fatigue caused by thermal striping was not considered in the piping fatigue design in several nuclear power plants, it is very important to evaluate the effect of thermal striping on the integrity of mixing tees. In the present work, before conducting detailed evaluation, three thermal striping evaluation methodology suggested by EPRI, JSME and NESC are analyzed. Then, a by-pass pipe connected to the shutdown cooling system heat exchanger is investigated by using these evaluation methodology. Consequently, the resulting thermal stresses and the fatigue life of the mixing tee are reviewed and compared to each other. Futhermore, the limitation of each methodology are also presented in this paper.

Shape Optimization of Waveguide Tee Junction in H-plane (자기 평면 도파관 소자의 최적형상설)

  • 이홍배;한송엽;천창열
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1020-1026
    • /
    • 1994
  • This paper presents a technique to optimize the shape of waveguide components in H-plane. The technique utilizes the numerical optimization process which employs the vector finite element method. In the optimization process, the sensitivity of an objective function with respect to design variables is computed by introducting adjoint variables, which makes the computation easy. The steepest descent method is then employed to update design variables. As a numerical example, an H-plane waveguide teejunction was considered to obtain optimized shape. Comparison between the initial and optimized shape was made.

A Novel Waveguide-based Ka-band Power Divider/Combiner Using Slotline-to-Microstrip Transitions (슬롯라인-마이크로스트립 변환을 이용한 도파관 형태의 Ka-band 전력 분배/결합기)

  • 정진호;천창율;권영우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.5C
    • /
    • pp.506-511
    • /
    • 2002
  • In this paper, waveguide-based power combiner using conventional slotline-to-microstrip transition was proposed at Ka-band. The proposed 2-way and 4-way power combiner consist of waveguide-to-slotline transition, two or four slotline-to-microstrip transitions, and impedance matching networks. Their structures were simulated and optimized by 3-D FEM simulation. The 2-way power combiner showed a very low back-to-back insertion loss of 1.0 dB and return loss better than 15 dB from 25.7 GHz to 29.8 GHz except the resonant frequency. The 2-way power combining approach was extended to 4-way power combining using slotline tee junction. The 4-way power combiner showed the similar performance to that of 2-way power combiner with 2 GHz smaller bandwidth.

Evaluation of thermal striping damage for a tee-junction of LMR secondary piping”

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Bong Yoo;Yoon, Sam-Son
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.837-843
    • /
    • 1998
  • This paper presents the thermomechanical and fracture mechanics evaluation procedure of thermal striping damage on the secondary piping of LMFR using Green's function method and standard FEM. The thermohydraulic loading conditions used in the present analysis are simplified sinusoidal thermal loads and the random type data thermal load. The thermomechainical fatigue damage was evaluated according to ASME code subsectionNH. The analysis results of fatigue for the sinusoidal and random load cases show that fatigue failure would occur at a geometrically discontinuous location during 90,000 hours of operation The fracture mechanics analysis showed that the crack would be initiated at an early stage of the operation. The fatigue crack was evaluated to propagate up to 5 ㎜ along the thickness direction during the first 944 and 1083 hours of operation for the sinusoidal and the random loading cases, respectively.

  • PDF

A New Type of 5-Pole Low Pass Filter Using Defected Ground Structure (결함 접지 구조를 이용한 새로운 5-단 저역 통과 여파기)

  • Lim Jong-Sik;Kim Chul-Soo;Ahn Dal;Jeong Yong-Chae;Nam Sangwook;Kim Kwangsoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.594-602
    • /
    • 2005
  • In this paper, a new type of 5-pole low pass filter(LPF) having defected ground structure(DGS) and very wide transmission line elements is proposed. The previously presented design method of 3-stage LPF using DGS is generalized to design N-pole LPFs for $N\geq5$. As an example, a 5-pole LPF having DGS is designed and measured. The accurate curve-fitting method to determine the series inductors in the prototype filter, and ultimately the size of DGS is described. The proposed 5-pole LPF has transmission line elements with a very low impedance to realize the required shunt capacitance instead of open stubs. Therefore, open stub. Therefore, open stub, Tee-junction, Cross-junction, and high impedance line are not required for the proposed LPF, while they all have been essential in conventional LPFs.

Tensile Behavior of CFT Column-to-H beam Connections with External T-shaped Stiffeners (T-스티프너 보강 콘크리트충전 각형강관 기둥-H형강 보 접합부의 인장거동)

  • Kang, Chang Hoon;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.121-130
    • /
    • 2002
  • This paper presents the tensile behavior of a Concrete-Filled Square Steel Tubular (CFT) column to H-beam welded connections. These connections were externally reinforced with T-shaped stiffeners at the junction of CFT column and beam. The tensile loading tests of eighteen tee-joint connections and finite element analysis using ANSYS were carried out. The main parameters of tests are as follows: 1) the thickness of Square Steel Tubular Column : 6 mm, 9 mm, 2) the strength ratios of tensile strength of horizontal stiffeners to tensile strength of beam flange : 70 %, 100 %, 150 %, 3) the strength ratios of shear strength of vertical stiffeners to tensile strength of beam flange : 80 %, 115 %, 160 %. The results of the tests demonstrate that overall behavior and failure modes of all the specimens are governed mainly by the horizontal stiffeners rather than the vertical stiffeners, and the vertical stiffener played only a role in transferring load introduced from beam to column.