• Title/Summary/Keyword: technology evaluation

Search Result 16,935, Processing Time 0.046 seconds

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

Quantitative Indices of Small Heart According to Reconstruction Method of Myocardial Perfusion SPECT Using the 201Tl (201Tl을 이용한 심근관류 SPECT에서 재구성 방법에 따른 작은 용적 심장의 정량 지표 변화)

  • Kim, Sung Hwan;Ryu, Jae Kwang;Yoon, Soon Sang;Kim, Eun Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: Myocardial perfusion SPECT using $^{201}Tl$ is an important method for viability of left ventricle and quantitative evaluation of cardiac function and now various reconstruction methods are used to improve the image quality. But in case of small sized heart, you should always be careful because of the Partial Volume Effect which may cause errors of quantitative indices at the reconstruction step. So, In this study, we compared those quantitative indices of left ventricle according to the reconstruction method of myocardial perfusion SPECT with the Echocardiography and verified the degree of the differences between them. Materials and Methods: Based on ESV 30 mL of Echocardiography, we divided 278 patients (male;98, female;188, Mean age;$65.5{\pm}11.1$) who visited the Asan medical center from February to September, 2012 into two categories; below the criteria to small sized heart, otherwise, normal or large sized heart. Filtered and output each case, we applied the method of FBP and OSEM to each of them, and calculated EDV, ESV and LVEF, and we conducted statistical processing through Repeated Measures ANOVA with indices that measured in Echocardiography. Results: In case of men and women, there were no significant difference in EDV between FBP and OSEM (p=0.053, p=0.098), but in case of Echocardiography, there were meaningful differences (p<0.001). The change of ESV especially women in small sized heard, significant differences has occurred among FBP, OSEM and Echocardiography. Also, in LVEF, there were no difference in men and women who have normal sized heart among FBP, OSEM and Echocardiography (p=0.375, p=0.969), but the women with small sized heart have showed significant differences (p<0.001). Conclusion: The change in quantitative indices of left ventricle between Nuclear cardiology image reconstruction, no difference has occurred in the patients with normal sized heart but based on ESV, under 30 mL of small sized heart, especially in female, there were significant differences in FBP, OSEM and Echocardiography. We found out that overestimated LVEF caused by PVE can be reduced in average by applying OSEM to all kinds of gamma camera, which are used in analyzing the differences.

  • PDF

Evaluating the Impact of Attenuation Correction Difference According to the Lipiodol in PET/CT after TACE (간동맥 화학 색전술에 사용하는 Lipiodol에 의한 감쇠 오차가 PET/CT검사에서 영상에 미치는 영향 평가)

  • Cha, Eun Sun;Hong, Gun chul;Park, Hoon;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.67-70
    • /
    • 2013
  • Purpose: Surge in patients with hepatocellular carcinoma, hepatic artery chemical embolization is one of the effective interventional procedures. The PET/CT examination plays an important role in determining the presence of residual cancer cells and metastasis, and prognosis after embolization. The other hand, the hepatic artery chemical embolization of embolic material used lipiodol produced artifacts in the PET/CT examination, and these artifacts results in quantitative evaluation influence. This study, the radioactivity density and the percentage error was evaluated by the extent of the impact of lipiodol in the image of PET/CT. Materials and Methods: 1994 NEMA Phantom was acquired for 2 minutes and 30 seconds per bed after the Teflon, water and lipiodol filled, and these three inserts into the enough to mix the rest behind radioactive injection with $20{\pm}10MBq$. Phantom reconfigure with the iterative reconstruction method the number of iterations for two times by law, a subset of 20 errors. We set up region of interest at each area of the Teflon, water, lipiodol, insert artifact occurs between regions, and background and it was calculated and compared by the radioactivity density(kBq/ml) and the% Difference. Results: Radioactivity density of the each region of interest area with the teflon, water, lipiodol, insert artifact occurs between regions, background activity was $0.09{\pm}0.04$, $0.40{\pm}0.17$, $1.55{\pm}0.75$, $2.5{\pm}1.09$, $2.65{\pm}1.16 kBq/ml$ (P <0.05) and it was statistically significant results. Percentage error of lipiodol in each area was 118%, compared to the water compared with the background activity 52%, compared with a teflon was 180% of the difference. Conclusion: We found that the error due to under the influence of the attenuation correction when PET/CT scans after lipiodol injection performed, and the radioactivity density is higher than compared to other implants, lower than background. Applying the nonattenuation correction images, and after hepatic artery chemical embolization who underwent PET/CT imaging so that the test should be take the consideration to the extent of the impact of lipiodol be.

  • PDF

A Study on the Use of Active Protocol Using the Change of Pitch and Rotation Time in PET/CT (PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구)

  • Jang, Eui Sun;Kwak, In Suk;Park, Sun Myung;Choi, Choon Ki;Lee, Hyuk;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.67-71
    • /
    • 2013
  • Purpose: The Change of CT exposure condition have a effect on image quality and patient exposure dose. In this study, we evaluated effect CT image quality and SUV when CT parameters (Pitch, Rotation time) were changed. Materials and Methods: Discovery Ste (GE, USA) was used as a PET/CT scanner. Using GE QA Phantom and AAPM CT Performance Phantom for evaluate Noise of CT image. Images are acquired by using 24 combinations that four stages pitch (0.562, 0.938, 1.375, 1.75:1) and six stages X-ray tube rotation time (0.5s-1.0s). PET images are acquired using 1994 NEMA PET Phantom ($^{18}F-FDG$ 5.3 kBq/mL, 2.5 min/frame). For noise test, noise are evaluated by standard deviation of each image's CT numbers. And then we used expectation noise according to change of DLP (Dose Length Product) to experimental noise ratio for index of effectiveness. For spatial resolution test, we confirmed that it is possible to identify to 1.0 mm size of the holes at the AAPM CT Performance Phantom. Finally we evaluated each 24 image's SUV. Results: Noise efficiency were 1.00, 1.03, 1.01, 0.96 and 1.00, 1.04, 1.02, 0.97 when pitch changes at the QA Phantom and AAPM Phantom. In case of X-ray tube rotation time changes, 0.99, 1.02, 1.00, 1.00, 0.99, 0.99 and 1.01, 1.01, 0.99, 1.01, 1.01, 1.01 at the QA Phantom and AAPM Phantom. We could identify 1.0 mm size of the holes all 24 images. Also, there were no significant change of SUV and all image's average SUV were 1.1. Conclusion: 1.75:1 pitch is the most effective value at the CT image evaluation according to pitch change and It doesn't affect to the spatial resolution and SUV. However, the change of rotation time doesn't affect anything. So, we recommend to use the effective pitch like 1.75:1 and adequate X-ray tube rotation time according to patient size.

  • PDF

Evaluation of Image Quality Using CT Attenuation Correction in SPECT/CT (SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가)

  • Cho, Sung Wook;Kim, Gye Hwan;Sung, Yong Joon;Lee, Hyung Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.78-83
    • /
    • 2013
  • Purpose: SPECT/CT, a combination of SPECT and CT, is capable of expressing the results of attenuation correction on images biased by automatic program. As a result, this research evaluates the usefulness of images with CT attenuation correction, using various phantoms and images of patients. Materials and Methods: From July of 2012 to September of 2012, this research was conducted on the contrast, spatial resolution, and images of patients. We studied the contrast with IEC body phantom and Jaszczak phantom, while the spatial resolution was evaluated with NEMA triple line phantom. Further, a comparative study was carried out on the quality of the images, on the difference between the images before and after the CT attenuation correction. Results: Compared the differences between the contrast before and after the CT attenuation correction in IEC body phantom. The contrast was improved by 33.6% at minimum, 89.8% at maximum. In case of Jaszczak Phantom, the contrast was enhanced by 9.9% at minimum, 27.8% at maximum. In NEMA Triple line phantom, the resolution was raised by 4.5% in average: 4.4% in horizontal, 4.5% in vertical. In Anthropomorphic Torso Phantom, the perfusion score of the interior wall with the most severe attenuation was measured to be 29.4%. In the experiment carried out on myocardial perfusion SPECT/CT patients, 9% improvement was discovered in the interior wall, where the most dramatic attenuation occurred, after the CT attenuation correction. Conclusion: SPECT/CT proved its clinical usefulness by enabling the acquisition of images with enhanced contrast and spatial resolution compare to the ones resulted from SPECT.

  • PDF

The Evaluation of Usefulness of 99Mo-99mTc Generator Using(n,γ)99Mo Developed by Korea Atomic Energy Research ((n,γ)99Mo를 이용한 99Mo-99mTc발생기의 유용성 평가)

  • Seo, Han Kyung;Kim, Jeong Ho;Shim, Cheol Min;Kim, Byung Cheol;Choi, Do Cheol;Gwon, Yong Ju;Park, Yung Sun;Kim, Dong Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: The Molybdenum which is the raw material of $^{99}Mo-^{99m}Tc$ generator is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. So $^{99}Mo-^{99m}Tc$ generator using$(n,{\gamma})^{99}Mo$ is developed by Korea Atomic Energy Research Institute (KAERI). Medicinal availability of this generator is evaluated in this study. Materials and Methods: The radioactivity of $^{99m}Tc$ eluted in generator 1, 2 and 3 unit developed by KAERI was measured. The quality control test of generator such as appearance test, pH test, LAL test, sterility test, chemical impurity (Al) test and radiochemical purity test were performed. Planar and SPECT/CT image sof SD rat (6 weeks, Female) at 2 hr after injection of $^{99m}Tc-HDP$ (hydroxymethylenediphosphonate) (TechneScan HDP, Malinckrodt Medical, Dutch) and $^{99m}Tc-DPD$ (diphosphono-1, 2-propanedicarboxylicacid) (TECEOS, CIS bio international, France) which were labeled with $^{99m}Tc$ eluted in KAERI and commercial generator (40.5 GBq, Malinckrodt Medical, Dutch) using SPECT/CT camera (Symbia, Siemense, Germany) were obtained respectively. Results: The mean radioactivity of $^{99m}Tc$ elution generator 1unit was 4.18 GBq (113 mCi), generator 2 unit was 4.73 GBq (128 mCi) and generator 3 unit was 3.33 GBq (90 mCi). All quality control tests were within normal limit except pyrogentest. Pyrogen test was positive. Planar and SPECT/CT images of rat injected $^{99m}Tc-HDP$ which was labeled with $^{99m}Tc$ eluted in commercial generator show increased uptake in bone, stomach and bowl. Planar images show increased uptake in liver and bone in case of $^{99m}Tc-DPD$. However, images of rat injected $^{99m}Tc-HDP$ and $^{99m}Tc-DPD$ which were labelled $^{99m}Tc$ eluted in KAERI generator show increased uptake in bone, liver and spleen. Conclusion: If shortcoming is removed such as pyrogen and liver appearance, domestic role as an alternative generator is thought to be able to fill and to secure the national medical service by supplying $^{99m}Tc$ when the supply of $^{99m}Tc$ be comes short.

  • PDF

Preparation of Semi-Solid Apple-Based Baby Food (반고형 사과 이유보충식의 제조)

  • Sohn, Kyung-Hee;Kim, Mi-Ran;Yim, Sung-Kyoung;Park, Hyun-Kyung;Park, Ok-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.43-50
    • /
    • 2002
  • To develop commercial semi-solid apple baby food, the physicochemical characteristics of apple puree in relation to different preparing methods and the effect of the addition methods of ascorbic acid on browning reaction were investigated. The preparing methods were classified into 3 groups by initial heating treatment: no heating (A), steaming at $120^{\circ}C$ (B), and blancing at $100^{\circ}C$ (C). The viscosity of tested apple puree was $2,600{\sim}5,856\;cp$, and contents of anhydrogalaturonic acid (AGA) and neutral sugar ranged $4.15{\sim}11.92\;mg%$ and $6.18{\sim}10.65\;mg%$, respectively. Among free sugars tested, level of fructose was the highest $(5.43{\sim}8.87%)$, followed by glucose $(2.11{\sim}4.23%)$, sucrose $(1.64{\sim}2.94%)$, in that order. Since small amounts of ascorbic acid were detected $(1.54{\sim}1.83\;mg%)$, it seemed to be lost by heating process in preparing of apple puree. For apple puree A, its lightness was lower and redness was higher than those of apple puree B and C. Its degree of browning of apple puree was so high that sodium ascorbic acid was added as a antibrowning agent. Puree had low sensory score and nutrient quality. The adding methods of ascorbic acid were classified into 4 groups by adding time: dipping, blending (2), heating (3), and blending + heating (4). Considering color and preference evaluation, preparing method B and adding method 2 showed the highest inhibitory activity on apple puree browning and desirable color for retort baby food. After retort sterilization, the viscosity of apple baby food was decreased from 3,477 cp to 2,294 cp, thiamin was destroyed completely, and the contents of riboflavin and ascorbic acid were decreased 41% and 21%, respectively. However, contents of free sugar and free amino acid and sensory parameter were not influenced by retort sterilization. In overall, the preparing method B-adding method 2 was a good processing condition for the retort apple baby food.

Factors Affecting Concentration of Polycyclic Aromatic Hydrocarbons in Oyster, Laver and Rockfish (굴, 김 및 조피볼락에서 다환성방향족탄화수소(Polycyclic Aromatic Hydrocarbons, PAHs)의 잔류에 미치는 요인에 대한 연구)

  • Kim, Kang-Jeon;Choi, Sang-Hoon;Park, Kwan-Ha
    • The Korean Journal of Malacology
    • /
    • v.24 no.3
    • /
    • pp.253-260
    • /
    • 2008
  • A total of 15 different residues of polycyclic aromatic hydrocarbons (PAHs) in each 20 samples of Pacific oysters, dried laver and rockfish obtained from seafood markets were analyzed. The prevalence of samples in which more than one PAH residues were found was 75% in oyster, 35% in rock fish hepatopancreas, 0% in rockfish muscle and laver, respectively. To estimate factors contributing to this residue level difference among organisms, tissue concentrations were analyzed after exposing three organisms to phenanthrene, a representative PAH, with concentration of 0.01 or $0.1{\mu}g/mL$ for 2 weeks. Phenanthrene levels after exposure were higher in the oyster digestive gland, laver and rockfish hepatopancreas, but were lower in the oyster whole meat or rockfish muscle. This finding disproved that any close relationship between the residue difference of market samples and concentrating properties of PAHs. The second possible factor analyzed was total lipid contents in the three organisms. Although higher lipid level in hepatopancreas of rockfish may contribute accumulation of PAH residues in the rockfish, lipid factor did not affect to PAH levels in other organism samples. Activity of 7-ethyoxyresorufin-O-deethylase (EROD), a kind of cytochrome $P_{450}$ enzyme, was measured to evaluate the eliminated amount of PAHs through metabolism. The higher EROD activity in rockfish, compared to that in oyster, was likely to contribute to the lower PAH residues in the rockfish. More factors, such as different exposure history, organisms' ability to escape, ingestion through prey organisms, and post-harvest loss, should be studied in the future.

  • PDF

Study on the Whitening Efficacy and Skin Barrier by Lysosome-related Organelle Extract (LOE) from Egg White (난백(Egg White)에서 추출한 리소좀 추출물(LOE)의 미백 효능 및 피부장벽에 관한 연구)

  • Choi, Da Hee;Jeon, Gyeongchan;Yoon, Jihee;Min, Jiho;Park, Si Jun;Kim, Jung Su;Hwang, Ee Taek;Hwang, Hyung Seo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.4
    • /
    • pp.389-397
    • /
    • 2019
  • Lysosomes are cellular organelles involved in energy metabolism and intracellular digestion in eukaryotic cells, including protease, nuclease, glycosidase, lipase, and phosphatase. Our previous studies have confirmed that egg white lysosomes had melanin decolorization and reduction activity. However, there have been few studies on skin barrier and skin regeneration as well as inhibition of melanin production by egg white lysosomes on B16F10 melanocyte cell line. In this study, we attempted to identify the effect of lysosome-related organelle extract (LOE) extracted from egg white on the melanin content change and skin barrier enhancement in cells. First, cytotoxicity evaluation was performed on B16F10 melanocyte cell line to confirm the whitening efficacy of LOE. Cytotoxicity by LOE was not observed at 20 mg/mL concentration, but cytotoxicity was observed at 40 mg/mL, and the maximum concentration value was set to 20 mg/mL in all subsequent experiments. LOE samples of 5, 10, 20 mg/mL inhibited melanin production by 61.5 ± 4.0%, 61.4 ± 7.3%, 58.3 ± 8.3%, respectivly, compared to α-MSH, a negative control in melanin contents assay. MITF mRNA expression was reduced by about 39.7 ± 3.2% compared to the α-MSH treatment group. TEER assay using HaCaT showed that LOE increased TEER resistance in a dose-dependent manner, indicating that LOE is involved in strengthening the skin barrier. LOE also increased the TEER resistance under TNF-α treatment. Skin barrier was normally restored by LOE even under the condition of inflammation. LOE had a positive effect on cell division and cell migration promotion, confirmed by the observing the effect of promoting cell migration by LOE through cell migration assay. Taken together, we expect that LOE can be developed as a cosmetic material to enhance has effects on skin regeneration and skin barrier strengthening as well as whitening function if enzyme stabilization and formulation technology are combined.

Physicochemical Changes in Olive Flounder (Paralichthys olivaceus) Muscle by Iced Water Pre-treatment (얼음물 전처리 방법이 넙치육의 품질특성에 미치는 영향)

  • Shin, Seung-Ho;Sung, Ki-Hyub;Chung, Chang-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.700-707
    • /
    • 2013
  • The purpose of this study was to monitor physicochemical changes of olive flounder (Paralichthys olivaceus) muscle by iced water pre-treatment. Moisture content, crude fat content, nucleotide content, texture (hardness and toughness), and rigor mortis were assessed. The sensory evaluation was performed with a nine-point hedonic test. K-values, a parameter of fish flesh freshness, were also calculated from the content of nucleotides and their corresponding decomposition products. Pre-treatment of flounder flesh with iced water was found to be fresher compared to the control, as determined by a difference in the K-values. Iced water pre-treatment hastened postmortem stiffness, as judged from the rigor index, and increased inosine monophosphate (IMP), which is known to be a savory taste compound, more quickly as adenosine triphosphate (ATP) degradation proceeded.