• Title/Summary/Keyword: technology acceptance

Search Result 2,225, Processing Time 0.03 seconds

Analysis on the International Trends in Safe Management of Very Low Level Waste Based upon Graded Approach and Their Implications (차등접근법에 근거한 극저준위폐기물의 안전관리 국제동향 및 시사점에 대한 고찰)

  • Cheong, Jae-Hak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.1
    • /
    • pp.49-62
    • /
    • 2011
  • Recently, International Atomic Energy Agency and major leading countries in radioactive waste management tend to subdivide the categories of radioactive waste based upon risk-graded approach. In this context, the category of very low level waste has been newly introduced, or optimized management options for this kind of waste have been pursued in many countries. The application of engineered surface landfill type facilities dedicated to dispose of very low level waste has been gradually expanded, and it was analyzed that their design concept of isolation has been much advanced than those of the old fashioned surface trench-type disposal facilities for low and intermediate level waste, which were usually constructed in 1960's. In addition, the management options for very low level waste in major leading countries are varied depending upon and interfaced with the affecting factors such as: national framework for clearance, legal and practical availability of low and intermediate level waste repository and/or non-nuclear waste landfill, public acceptance toward alternative waste management options, and so forth. In this regard, it was concluded that optimized long-term management options for very low level waste in Korea should be also established in a timely manner through comprehensive review and discussions, in preparation of decommissioning of large nuclear facilities in the future, and be implemented in a systematic manner under the framework of national policy and management plan for radioactive waste management.

Development of Sorption Database (KAERI-SDB) for the Safety Assessment of Radioactive Waste Disposal (방사성폐기물 처분안전성 평가 자료 제공을 위한 핵종 수착 데이터베이스(KAERI-SDB) 개발)

  • Lee, Jae-Kwang;Baik, Min-Hoon;Jeong, Jongtae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.1
    • /
    • pp.41-54
    • /
    • 2013
  • Radionuclide sorption data is necessary for the safety assessment of radioactive waste disposal. However the use of sorption database is often limited due to the accessability. A web-based sorption database program named KAERI-SDB has been developed to provide information on the sorption of radionuclides onto geological media as a function of geochemical conditions. The development of KAERI-SDB was achieved by improving the performance of pre-existing sorption database program (SDB-21C) developed in 1998 and considering user's requirements. KAERI-SDB is designed that users can access it by using a web browser. Main functions of KAERI-SDB include (1) log-in/member join, (2) search and store of sorption data, and (3) chart expression of search results. It is expected that KAERI-SDB could be widely utilized in the safety assessment of radioactive waste disposal by enhancing the accessibility to users who wants to use sorption data. Moreover, KAERI-SDB opened to public would also improve the reliability and public acceptance on the radioactive waste disposal programs.

Explicating Motivations & Attitudes Affecting the Persistent Intention to Adopt Binge-Watching (수용자의 몰아보기 이용동기와 지속적 이용의도에 영향을 미치는 영향 요인에 대한 연구)

  • Han, Sun Sang;Yu, Hongsik;Shin, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.2
    • /
    • pp.521-534
    • /
    • 2017
  • In 2013 the Netflix, an OTT in USA, launched all at once 13 episodes of the House of Cards season. Binge-watching is the word which means watching continuously 2~6 episodes of a TV program with one sitting, the new normal of TV watching behavior, cultural and social currents all over the world. This study has analyzed the factors and motivations which affect to the persistent intention to use binge-watching. It conducted an online survey from 333 Quota sample from Korean age groups between 20th~60th with 81 questionnaires. The 5 groups were induced as motivation factors to binge-watching. The 3 groups which consisted of , , are affecting as positive to intention to use binge-watching. But the other 2 groups which are and doing as negative. The survey has shown that the persistent intention to binge-watching is affected by ages more younger, whom doing binge watching more frequently, whom estimating more higher to the conceived usefulness to use. As a theoretical model, expanded technology acceptance model was adopted and US drama House of Cards. This study could promote the next generation contents planning and S-VOD service industry.

Bioequivalence of Kyongbocefaclor Capsule to Ceclor Capsule (Cefaclor 250 mg) (시클러 캡슐(세파클러 250 mg)에 대한 경보세파클러 캡슐의 생물학적동등성)

  • Cho, Hea-Young;Kang, Hyun-Ah;Kim, Se-Mi;Park, Chan-Ho;Oh, In-Joon;Lim, Dong-Koo;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.1
    • /
    • pp.39-44
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two cefaclor capsules, Ceclor (Lilly Korea Co., Ltd.) and Kyongbocefaclor (Kyongbo Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of cefaclor from the two cefaclor formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty four healthy male subjects, $22.96{\pm}1.52$ years in age and $67.03{\pm}7.90$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After one capsule containing 250 mg of cefaclor was orally administered, blood was taken at predetermined time intervals and the concentrations of cefaclor in serum were determined using HPLC method with UV detector. The dissolution profiles of two formulations were similar at all dissolution media. In addition, the pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Ceclor, were -1.90%, 2.68% and -7.60% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 $(e.g.,\;log0.91{\sim}log\;1.06\;and\;log0.92{\sim}log\;1.18\;for\;AUC_t\;and\;C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Kyongbocefaclor capsule was bioequivalent to Ceclor capsule.

Bioequivalence of Yutanal® Capsule to Harnal® Capsule (Tamsulosin HCl 0.2 mg) (하루날® 캡슐(염산 탐스로신, 0.2 mg)에 대한 유타날® 캡슐의 생물학적동등성)

  • Im, Ho-Taek;Cho, Sung-Hee;Lee, Heon-Woo;Park, Wan-Su;Kim, Young-Kwan;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.309-315
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of tamsulosin HCl capsule, $Harnal^{\circledR}$(Jeil Korea Ltd.) and $Yutanal^{\circledR}$(Kukje Korea Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four normal male volunteers, $23.29{\pm}2.14$ year in age and $72.08{\pm}7.83$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one capsule containing 0.2 mg of tamsulosin HCl were orally administered, blood was taken at predetermined time intervals and concentrations of tamsulosin in plasma were determined using LC-MS/MS. Pharmacokinetic parameters such as $AUC_t$, $T_{max}$ and $C_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals for the log transformed data were acceptance range of log0.8 to log1.25 (e.g., $log0.93{\sim}log1.11$ and $log0.80{\sim}log0.94$ for $AUC_t$, and $C_{max}$, respectively). The major parameters, $AUC_t$, and $C_{max}$, met the criteria of KFDA for bioequivalence indicating that $Yutanal^{\circledR}$ capsule is bioequivalent to $Harnal^{\circledR}$ capsule.

Bioequivalence of Tylicol ER Tablet to Tylenol® ER Tablet (Acetaminophen 650 mg) (타이레놀이알서방정(아세트아미노핀 650 mg)에 대한 타이리콜이알정의 생물학적동등성)

  • Kang, Hyun-Ah;Kim, Dong-Ho;Park, Sun-Ae;Yun, Hwa;Kim, Kyung-Ran;Park, Eun-Ja;Cho, Hea-Yeong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.201-207
    • /
    • 2006
  • Acetaminophen (paracetamol), a para-aminophenol derivative, has analgesic and antipyretic properties and weak anti-inflammatory activity. The purpose of the present study was to evaluate the bioequivalence of two acetaminophen tablets, $Tylenol^{\circledR}$ ER (Janssen Korea Ltd.) and Tylicol ER (Hana Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of acetaminophen from the two acetaminophen formulations in vitro was tested using KP VIll Apparatus II method with pH 1.2 buffer solution. Twenty six healthy male subjects, $22.8{\pm}1.99$ years in age and $65.6{\pm}8.03$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 650 mg as acetaminophen was orally administered, blood samples were taken at predetermined time intervals and the concentrations of acetaminophen in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in pH 1.2 buffer solution. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Tylenol^{\circledR}$ ER, were 2.84, 1.89 and -1.36% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log $0.987{\sim}log$ 1.08 and log $0.944{\sim}log$ 1.17 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Tylicol ER tablet was bioequivalent to $Tylenol^{\circledR}$ ER tablet.

Bioequivalence of Glycomin Tablet to Glucophage Tablet (Metformin HCl 500 mg) (굴루코파지 정(염산메트폴민 500 mg)에 대한 그리코민 정의 생물학적 동등성)

  • Cho, Hea-Young;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.3
    • /
    • pp.223-229
    • /
    • 2002
  • Metformin is an oral antihyperglycemic agent used in the therapy of noninsulin-dependent diabetes mellitus and does not cause hypoglycemia at the therapeutic dose. Its mechanism of action may involve an increased binding of insulin to its receptors and glucose uptake at the post-receptor level. The purpose of the present study was to evaluate the bioequivalence of two metformin tablets, Glucophage (Daewoong Pharmaceutical Co., Ltd.) and Glycomin (Ilsung Pharmaceuticals Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The metformin release from the two metformin tablets in vitro was tested using KP VII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty four normal male volunteers, $23.75{\pm}1.96$ years in age and $68.77{\pm}10.41\;kg$ in body weight, were divided into two groups with a randomized $2{\times}2$ cross-over study. After one tablet containing 500 mg as metformin was orally administered, blood was taken at predetermined time intervals and the concentrations of metformin in serum were determined using HPLC with UV detector. Besides, the dissolution profiles of two metformin tablets were very similar at 떠1 dissolution media. The pharmacokinetic parameters such as $AVC_t,\;C_{max}\;and\;T_{max}$ were calculated. The ANOVA test was performed for the statistical analysis of the logarithmically transformed $AVC_t\;and\;C_{max}$, untransformed $T_{max}$. The results showed that the differences in $AVC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on the Glucophage were 0.09%, 6.09% and -8.22%, respectively. There were no sequence effects between two tablets in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) $(e.g.,\;log(0.94){\sim}log(1.09)\;and \;log(1.01){\sim}log(1.15)$\;for\;AVC_t\;and\;C_{max},\;respectively)$, indicating that Glycomin tablet is bioequivalent to Glucophage tablet.

Bioequivalence of Kuhnil Propiverine Hydrochloride Tablet to BUP-4 Tablet (Propiverine Hydrochloride 20 mg) (비유피-4 정(염산프로피베린 20 mg)에 대한 건일염산프로피베린 정의 생물학적동등성)

  • Cho, Hea-Young;Park, Eun-Ja;Kang, Hyun-Ah;Baek, Seung-Hee;Kim, Se-Mi;Park, Chan-Ho;Oh, In-Joon;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.419-425
    • /
    • 2004
  • The purpose of the present study was to evaluate the bioequivalence of two propiverine hydrochloride tablets, BUP-4 (Jeil Pharm. Co., Ltd.) and Kuhnil Propiverine Hydrochloride (Kuhnil Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The propiverine release from the two propiverine hydrochloride formulations in vitro was tested using KP VIII Apparatus II method with a variety of dissolution media (pH 1.2, 4.0, 6.8 buffer solutions, water and blend of polysorbate 80 into pH 6.8). Twenty six healthy male subjects, $23.73{\pm}2.79$ years in age and $67.04{\pm}7.93\;kg$ in body weight, were divided into two groups and a randomized $2\;{\times}\;2$ cross-over study was employed. After one tablet containing 20 mg as propiverine hydrochloride was orally administered, blood was taken at predetermined time intervals and the concentrations of propiverine in serum were determined using HPLC method with UV detector. The dissolution profiles of two formulations were similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t,\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the BUP-4 were 0.17%, 7.98% and 4.55% for $AUC_t,\;C_{max}\;and\;T_{max}$. respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(1.25) $(e.g.,\;log(0.88){\sim}log(1.l2)\;and\;log(0.90){\sim}log(1.l5)\;for\;AUC_t\;and\;C_{max},\;respectively)$. Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Kuhnil Propiverine Hydrochloride tablet was bioequivalent to BUP-4 tablet.

Bioequivalence of Broadcef Capsule to Cefradine Yuhan Capsule (Cephradine 500 mg) (유한세프라딘 캅셀(세프라딘 500 mg)에 대한 브로드세프 캅셀의 생물학적 동등성)

  • Cho, Hea-Young;Lee, Suk;Kang, Hyun-Ah;Oh, In-Joon;Lim, Dong-Koo;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.3
    • /
    • pp.215-221
    • /
    • 2002
  • Cephradine is a first generation cephalosporin and has broad spectrum antibacterial activity against gram-positive and gram-negative microorganisms, through inhibition of bacterial cell wall synthesis. Cephradine is useful for treatment of infections of the urinary and respiratory tract, skin and soft tissues. The purpose of the present study was to evaluate the bioequivalence of two cephradine capsules, Cefradine Yuhan (YuHan Corporation) and Broadcef (Ilsung Pharmaceuticals Co. Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The cephradine release from the two cephradine capsules in vitro was tested using KP VII Apparatus II method with various different kinds of dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty normal male volunteers, $23.10{\pm}2.90$ years in age and $67.69{\pm}8.04\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one capsule containing 500 mg as cephradine was orally administered, blood was taken at predetermined time intervals and the concentrations of cephradine in serum were determined using HPLC method with UV detector. The dissolution profiles of two cephradine capsules were very similar at all dissolution media. Besides, the pharmacokinetic parameters such as $AVC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AVC_t\;and\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences in $AVC_t,\;C_{max}\;and\;T_{max}$ between two capsules based on the Cefradine Yuhan were -2.87%, -0.96% and -4.85%, respectively. There were no sequence effects between two capsules in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of 1og(0.8) to log(1.25) $(e.g.,\;log(0.93){\sim}log(1.02)\;and\;log(0.88){\sim}log(1.13)\;for \;AVC_t\;and\;C_{max},\;respectively)$. The 90% confidence interval using untransformed data was within ${\pm}20%$ $(e.g., \;-17.54{\sim}7.78\;for\;T_{max})$. All parameters met the criteria of KFDA guideline for bioequivalence, indicating that Broadcef capsule is bioequivalent to Cefradine Yuhan capsule.

Bioequivalence of Kuhnil GabapentinTM Capsule 300 mg to NeurontinTM Capsule 300 mg (Gabapentin 300 mg) (뉴론틴 캡슐 300밀리그람(가바펜틴 300 mg)에 대한 건일가바펜틴 캡슐 300밀리그람의 생물학적동등성)

  • Cho, Hea-Young;Kang, Hyun-Ah;Park, Eun-Ja;Oh, Se-Won;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.193-199
    • /
    • 2005
  • Gabapentin is an antiepileptic drug that is structurally similar to ${\gamma}-aminobutyric$ acid (GABA), but does not interact with the GABA receptor. It does not bind significantly to plasma proteins, and is excreted to unchanged form in the urine. The purpose of the present study was to evaluate the bioequivalence of two gabapentin capsules, $Neurontin^{TM}$ capsule 300 mg (Pfizer Pharm. Co., Ltd.) and Kuhnil $Gabapentin^{TM}$ capsule 300 mg (Kuhnil Pharm. Co., Ltd), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of gabapentin from the two gabapentin formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty six healthy male subjects, $22.46{\pm}1.86$ years in age and $67.64{\pm}7.24$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single capsule containing 300 mg as gabapentin was orally administered, blood samples were taken at predetermined time intervals and the concentrations of gabapentin in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar at all dissolution media. In addition, the pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Neurontin^{TM}$ capsule 300 mg, were -2.03, -0.43 and 4.29% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 $(e.g.,\;log\;0.89{\sim}log\;1.09\;and\;log\;0.91{\sim}log\;1.09$ for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Kuhnil $Gabapentin^{TM}$ capsule 300 mg was bioequivalent to $Neurontin^{TM}$ capsule 300 mg.