• Title/Summary/Keyword: technique effect

Search Result 6,944, Processing Time 0.038 seconds

Fracture Characteristic of TiNi/A16061 Share Memory Alloy Composite using Acoustic Emission Technique (AE 기법을 이용한 TiNi/A16061 형상기억복합재료의 파괴특성평가)

  • Lee, Jin-Kyung;Park, Young-Chul;Ku, Hoo-Taek;Park, Dong-Sung;Lee, Kyu-Chang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.275-282
    • /
    • 2002
  • Tensile residual stress happen by difference of coefficients of thermal expansion between fiber and matrix is one of the serious problems in metal matrix composite(MMC). In this study, TiNi fiber was used to solve the tensile residual stress as the reinforced material. TiNi fiber improves the tensile strength of composite by occurring compressive residual stress in matrix using shape memory effect of it. Pre-strain was added to generate compressive residual stress inside TiNi/A16061 composite. It was also evaluated the effect of compressive residual stress corresponding to pre-strains variation. AE technique was used to clarify the microscopic damage behavior at high temperature and the effect of pre-strain difference of TiNi/A16061 shape memory alloy composite.

Combined Effects of Physical Evidence and Functional Service at Bulgogi Restaurants on Customers' Store Image and Purchase Behaviors: Application of Video Scenario Technique

  • Hwang, Daye;Chang, Hyeja
    • Journal of the Korean Society of Food Culture
    • /
    • v.35 no.2
    • /
    • pp.181-192
    • /
    • 2020
  • This study aimed to identify whether or not four service situations varying according to positive and negative combinations of physical evidence and functional service influence store image and purchase behavioral intentions of customers at bulgogi restaurants. The video-scenario technique was used for the study. Data were analyzed with the SPSS (Window 19.0) package using frequency analysis, one-way ANOVA, 2 by 2 factorial ANOVA, exploratory factor analysis, and multiple regression analysis to confirm the hypotheses. The combined effect of functional service and physical evidence influenced store image and purchase intention. In terms of seperate effect of physical evidence and functional service, the effect of employee service on store image was more powerful than that of physical evidence, even though the effect differed depending on the situation. Purchase intention was only influenced by functional service quality from employees under the four different scenarios. Thus, when opening a Korean restaurant, proper management of tangible evidence suitable to service, and the prices expected from local customers should be determined. Additionally, extremely high or low levels of physical evidence management should be avoided.

A Research on the Magnitude/Phase Asymmetry Measurement Technique of the RF Power Amplifier Based on the Predistortive Tone Cancellation Technique

  • Choi, Heung-Jae;Shim, Sung-Un;Kim, Young-Gyu;Jeong, Yong-Chae;Kim, Chul-Dong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.2
    • /
    • pp.73-77
    • /
    • 2010
  • This paper proposes a novel memory effect measurement technique in RF power amplifiers(PAs) using a two-tone intermodulation distortion(IMD) signal with a very simple and intuitive algorithm. Based on the proposed predistortive tone cancellation technique, the proposed measurement method is capable of measuring the relative phase and magnitude of the third-order and fifth-order IMDs, as well as the fundamental signal. The measured relative phase between the higher and lower IMD signal for specific tone spacing can be interpreted as the group delay(GD) information of the IMD signal concerned. From the group delay analysis, we can conclude that an adaptive control of GD as well as the magnitude and phase is a key function in increasing the linearization bandwidth and the dynamic range in a predistortion(PD) technique.

Ultrasonic Inspection of Cracks in Stud Bolts of Reactor Vessels in Nuclear Power Plants by Signal Processing of Differential Operation

  • Choi, Sang-Woo;Lee, Joon-Hyun;Oh, Won-Deok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.439-445
    • /
    • 2005
  • The stud bolt is one of crucial parts for safe operation of reactor vessels in nuclear power plants, Crack initiation and propagation were reported in stud bolts that arc used for closure of reactor vessel and head, Stud bolts are inspected by ultrasonic technique during overhaul periodically for the prevention of stud bolt failure which could induce radioactive leakage from nuclear reactor, In conventional ultrasonic testing for inspection of stud bolts, cracks are detected by using shadow effect It takes too much time to inspect stud bolts by using conventional ultrasonic technique. In addition, there were numerous spurious signals reflected from every oblique surfaces of thread, In this study, the signal processing technique for enhancing conventional ultrasonic technique was introduced for inspecting stud bolts. The signal processing technique provides removing spurious signal reflected from every oblique surfaces of thread and enhances detectability of defects. Detectability for small crack was enhanced by using this signal processing in ultrasonic inspection of stud bolts in Nuclear Power Plants.

New Social Video Techniques through The Convergence of a Social Video and Color Marketing (소셜 영상과 컬러 마케팅의 융합을 통한 새로운 소셜 영상 기법)

  • Lim, Seungae;Choi, Hakhyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • In this paper, it aims to get an effective marketing strategy in terms of business by introducing combined social video and color marketing technique. The process of research will be implementing a stop motion technique video by combining a black and white video with an extracted color image and then, further investigates each process. The expected result is that the effects can contribute to the development and the activation of company or brand's social video marketing by using the new video production technique. From the perspective of a company, the technique can effect in a positive way. They can provide consistent message to customers (public) by the color effect which contain brand's core message.

Corrosion fatigue crack growth behavior of 316LN stainless steel in high-temperature pressurized water

  • Zhang, Ziyu;Tan, Jibo;Wu, Xinqiang;Han, En-Hou;Ke, Wei
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2977-2981
    • /
    • 2021
  • Corrosion fatigue crack growth (FCG) behavior of 316LN stainless steel was investigated in high-temperature pressurized water at different temperatures, load ratios (R = Kmax/Kmin) and rise times (tR). The environmental assisted effect on FCG rate was observed when both the R and tR exceeded their critical values. The FCG rate showed a linear relation with stress intensity factor range (ΔK) in double logarithmic coordinate. The environmental assisted effect on FCG rate depended on the ΔK and quantitative relations were proposed. Possible mechanisms of environmental assisted FCG rate under different testing conditions are also discussed.

Effects of HR-AC Techniques and Kinesio Taping on Pain Changes in Delayed Onset Muscle Soreness (지연성근육통에 적용한 HR-AC기법과 키네시오 테이핑이 통증 변화에 미치는 영향)

  • Bae, Sea-hyun;Kim, Kyung-yoon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Background: This study aimed to investigate the effect of hold-relax and antagonist contraction (HR-AC) technique and Kinesio taping on pain changes in delayed-onset muscle soreness (DOMS) of 20's adults. Methods: Based on voluntary participation, 14 participants with induced-DOMS were randomly divided into control (non-treatment, n=7) and experiment group (HR-AC technique and kinesio taping, n=7). Measurement were used visual analogue scale (VAS), heart rate variability (HRV), and brain wave (alpha). There were 5 sets of the HR-AC technique application on the 5th day from the day of DOMS induction (rest for 30s between sets). Kinesio taping was applied to the same area after HR-AC. Results: The VAS showed significant changes according to the period and in the interaction between the period and the group (p<.01). HRV and alpha wave (Fp1) showed significant changes according to the period (p<.001). The analgesic effect was more rapid and continuous in the experimental group than in the control group. Conclusion: This study showed that the HR-AC technique and Kinesio taping are effective interventions for the management of pain and stress caused by DOMS.

PMD Effect on the Clock-based Optimum Dispersion Compensation Monitoring Technique

  • Kim, Sung-Man
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.112-115
    • /
    • 2009
  • We investigate the effect of polarization-mode dispersion (PMD) on the optimum dispersion compensation (ODC) monitoring and nonlinear penalty in optical transmission systems. We report that PMD may reduce the fiber nonlinearity. We also report that the monitoring error of the clock-based ODC monitoring technique decreases after the first-order PMD compensation. A simple explanation of this phenomenon is shown.

Effect of Hold-Relax Technique for College Students with Hamstring Shortening (슬괵근 단축이 있는 대학생에 대한 유지-이완 기법의 효과)

  • Oh, Yeong-Taek
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.3
    • /
    • pp.433-441
    • /
    • 2013
  • PURPOSE: The purpose of this study was to determine the effectiveness of three PNF stretching techniques for improving hamstring flexibility and to compare the effectiveness of three PNF stretching techniques(direct and indirect and mix(direct&indirect) of hold-relax technique). METHODS: The subjects were randomly assigned into three groups: group1-direct-hold-relax technique(n=10); group2-indirect-hold-relax technique(n=8); group3-mix(direct&indirect)-hold-relax technique(n=10). For each group, stretch was performed three times a week for a period of three weeks. Hamstring flexibility for each group was measured using the ASLR and PSLR. RESULTS: The results showed significant improvement in hamstring flexibility for all subjects of three groups. However, were not significantly different between the three groups. CONCLUSION: In conclusion, three PNF stretching techniques are confirmed to be useful for improving hamstring flexibility. The choice for a qualified technique has to be made individually according to patient and therapist.

Comparison of Two Intramuscular Injection Techniques on the Severity of Discomfort and leasions at the Injection Site (근육주사법에 따른 주사부위의 불편감과 조직손상의 차이에 관한 연구)

  • 김경선
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.3
    • /
    • pp.257-268
    • /
    • 1988
  • The purpose of this study was to compare the effect of the Z-track intramuscular injection technique with the effect of the stand and intramuscular injection technique on the severity of discomfort and leasions at the injection site. The subjects of the study were 20 patients with only early tuber culosis excluding another abnormalities (a akin rash, allergy to topical use of alcohol, jaundice, edema, neurosensory abnormality, coagulation defects, obesity and thin). Data collection was done from Feb. 1 to March 15, 1988 by means of Korean Pain Measurement Tool, Visual Analogue Scale, and Objective measures of injection site lesions. The results of this study were as follows ; 1) Hypothesis 1 ; “The severity of subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion injection technique.” was not sopported 2) Hypothesis 2 ; “The degress of severity subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion of the standard intramuscular injection technique.” was not supported. 3) Hypothesis 3 ; “The severity of injection site lesions is less following administra tion of the Z-track intramuscular injection technique than following administration of the standard intramuscular injection techniques.” was not supported. 4) The terms that were selected included factor II (mild-moderate pain) of Ratio Scale Measuring Pain using Korean Pain Terms. In conclusion ; it was found that there was not a difference from the severity of subject discomfort between two groups, but the degress of severity of subject discomfort about following administration of the Z-t-rack intramuscular injection was tended to be declined. Therefore further studies suggest that the Z-track intramuscular injection technique can decrease the severity of discomfort in persons receiving frequently intramuscular injections. First of all, it is necessery to be developed an effective tool of discomfort measurement for the intramuscular injection in Korean.

  • PDF