• Title/Summary/Keyword: tapered

Search Result 902, Processing Time 0.037 seconds

An Experimental Study on the Failure of a Novel Composite Sandwich Structure (새로운 형상의 복합재 샌드위치 체결부 구조의 파손거동 연구)

  • Kwak, Byeong-Su;Kim, Hong-Il;Dong, Seung-Jin;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • The failure of composite sandwich structures with thickness and material variation was studied. The main body of the structure is sandwich plate made of the carbon composite face and Aluminum honeycomb core. It is connected with composite laminated flange without core through transition region of tapered sandwich panel with foam core. Tension and compression tests were conducted for the total of 6 panels, 3 for each. Test results showed that the panels under compression are vulnerable to the face failure along the material discontinuity line between two different cores. However the failure load of which panel does not show such failure can carry 16% more load and fails in honeycomb core and face debonding. For the tensile load, the extensive delamination failure was observed at the corner radius which connects the panel and the flange. The average failure load for compression is about 7 times the tensile failure load. Accordingly, these sandwich structures should be applied to the components that endure the compressive loadings.

Safety and Effectiveness of Long Acting Injectable Antipsychotic Paliperidone Palmitate Treatment in Schizophrenics : A 24-Week Open-Label Study (조현병 환자에서 장기지속형 항정신병 주사제 팔리페리돈 팔미테이트의 효능과 안전 : 24주 개방형 연구)

  • Kang, Hyun-Ku;Hahm, Woong;Shon, In-Ki;Paik, In-Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.20 no.3
    • /
    • pp.111-117
    • /
    • 2013
  • Objectives We investigated the effectiveness and safety when treated in schizophrenics with paliperidone palmitate, a long acting injectable antipsychotic. Methods This was a 24-week open-label study, performed at one center in Korea. The eligible patients with schizophrenia diagnosed by Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) criteria were enrolled. Patients received long-acting paliperidone palmitate injection (234 mg, baseline; 156 mg, week 1 ; then once 4 weeks flexible dosing). Effectiveness assessments were measured by the Positive and Negative Syndrome Scale (PANSS), The Clinical Global Impression Severity Scale (CGI-S), The Personal and Social Performance (PSP) at baseline, week 1, every 4 weeks untill 24 weeks or endpoint. Safety assessments were measured by The Extrapyramidal Symptom Rating Scale (ESRS), body weight (BW) and incidence of adverse events. Oral antipsychotics were stopped or tapered off within next 14 days. Results Of 20 patients recruited, 9 patients (45%) completed the study. Paliperidone palmitate produced a significant improvement in PANSS total score from baseline to endpoint. The response rate was 75% [mean change (${\pm}SD$) $-25.9{\pm}14.4$, all p < 0.001]. The CGI-S and PSP total scores significantly improved during 24 weeks (All p < 0.001). Eighty percent of patients reported adverse events and most common adverse events (${\geq}10%$) in paliperidone palmitate were anticholinergic adverse event, extrapyramidal symptoms, weight gain, akathisia, insomnia, headache, agitation, anxiety and GI trouble. ESRS score is not statistically significant, but tends to get better at the end of the study when compared to baseline. Conclusions Our study results demonstrated maintained effectiveness and safety of paliperidone palmitate treatment in schizophrenics. And provides both clinicians and patients with a new choice of treatment that can improve the outcome of long term therapy. Their potential effectiveness and safety should be better addressed by future randomized-controlled trials.

Analysis of inner parts in the disc cutters applied to the field tests (현장적용 디스크커터의 내부부품 분석)

  • Bae, Gyu-Jin;Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Song, Bong-Chan;Kim, Kab-Boo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.4
    • /
    • pp.473-485
    • /
    • 2015
  • The problems for non-rotating of a disc cutter proceed from the faults in inner parts of the disc cutter such as the leak of hydraulic fluid, the intrusion of tunnel mucks and water, overloading, overheating, poor assembly and substandard material. The rotating of a disc cutter is an indicator to show that the inner parts of disc cutter is operable, although the rotational torque depends on the extent of the damage. Therefore, the key in the problems for non-rotating of disc cutter is to maintain that the tapered roller bearings are working properly. This study aims to investigate the inner parts disassembled from disc cutters applied to the field tests in order to help decision for reuse of the disc cutters. As results, surface finishing to remove the scratch on the load zone of the hubs is needed, with the intent to reuse a hub. And the investigation of lapping surface by optical microscope of floating seals and the contamination test of oil need to be performed for reuse of a disc cutter. Especially, the analysis results show that the floating seals play a key role in the normal operation of bearings. There is nothing significant to report in the rest parts such as bearing, shaft, seal retainers.

Analysis of crown size and morphology, and gingival shape in the maxillary anterior dentition in Korean young adults

  • Song, Jae-Won;Leesungbok, Richard;Park, Su-Jung;Chang, Se Hun;Ahn, Su-Jin;Lee, Suk-Won
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.315-320
    • /
    • 2017
  • PURPOSE. The aim of this investigation was to analyze the dimensions of clinical crowns and to classify the crown and the gingival type in the anterior teeth in Korean young adults. MATERIALS AND METHODS. Casts were obtained from 50 subjects ranging in age from 24 to 32. Measurements of length and width were made on the casts using a pair of digital calipers on the entire dentition. Crown thickness and papilla height were also measured and MDW/CL (mesiodistal width to clinical length) and CW/CL (cervical width to clinical length) ratios of the maxillary anterior teeth were calculated. The K-clustering method was used for CW/CL to classify the anterior tooth shape into three groups (tapered, ovoid, and square), and one-way analysis of variance and Duncan's post-hoc comparison were used to evaluate statistical significance between the groups. Pearson's correlation analysis was performed between tooth shape and papillary height (PH) to demonstrate the correlation between tooth shape and gingival morphological characteristics. RESULTS. The average length of the maxillary central incisors was 9.89 mm; the mesio-distal width was 8.54 mm; and the ratio of width/length was 0.86 in Korean young adults. The average bucco-palatal thickness of the central incisor was 3.14 mm at the incisal 1/3 aspect. Ovoid type was the most common tooth shape (48%), followed by square type (29%) and taper type (23%) in the central incisors of Korean young adults. Tooth shape and gingival type were correlated with each other. CONCLUSION. New reference data were established for tooth size in Korean young adults and the data show several patterns of tooth shape and gingival type. Clinicians should diagnose and treat based on these characteristics for better results in the Korean population.

Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits (가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구)

  • Kim, Sang-Soo;Lee, Ju-Hyung;Yu, Seok-Hyun;Lee, Hyung-Ju;Moon, Jee-Won;Park, In-Sook;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

Fabrication of Microwire Arrays for Enhanced Light Trapping Efficiency Using Deep Reactive Ion Etching

  • Hwang, In-Chan;Seo, Gwan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.454-454
    • /
    • 2014
  • Silicon microwire array is one of the promising platforms as a means for developing highly efficient solar cells thanks to the enhanced light trapping efficiency. Among the various fabrication methods of microstructures, deep reactive ion etching (DRIE) process has been extensively used in fabrication of high aspect ratio microwire arrays. In this presentation, we show precisely controlled Si microwire arrays by tuning the DRIE process conditions. A periodic microdisk arrays were patterned on 4-inch Si wafer (p-type, $1{\sim}10{\Omega}cm$) using photolithography. After developing the pattern, 150-nm-thick Al was deposited and lifted-off to leave Al microdisk arrays on the starting Si wafer. Periodic Al microdisk arrays (diameter of $2{\mu}m$ and periodic distance of $2{\mu}m$) were used as an etch mask. A DRIE process (Tegal 200) is used for anisotropic deep silicon etching at room temperature. During the process, $SF_6$ and $C_4F_8$ gases were used for the etching and surface passivation, respectively. The length and shape of microwire arrays were controlled by etching time and $SF_6/C_4F_8$ ratio. By adjusting $SF_6/C_4F_8$ gas ratio, the shape of Si microwire can be controlled, resulting in the formation of tapered or vertical microwires. After DRIE process, the residual polymer and etching damage on the surface of the microwires were removed using piranha solution ($H_2SO_4:H_2O_2=4:1$) followed by thermal oxidation ($900^{\circ}C$, 40 min). The oxide layer formed through the thermal oxidation was etched by diluted hydrofluoric acid (1 wt% HF). The surface morphology of a Si microwire arrays was characterized by field-emission scanning electron microscopy (FE-SEM, Hitachi S-4800). Optical reflection measurements were performed over 300~1100 nm wavelengths using a UV-Vis/NIR spectrophotometer (Cary 5000, Agilent) in which a 60 mm integrating sphere (Labsphere) is equipped to account for total light (diffuse and specular) reflected from the samples. The total reflection by the microwire arrays sample was reduced from 20 % to 10 % of the incident light over the visible region when the length of the microwire was increased from $10{\mu}m$ to $30{\mu}m$.

  • PDF

Modeling of the Cycle Life of a Lithium-ion Polymer Battery (리튬 이온 폴리머 전지의 사이클 수명 모델링)

  • Kim, Ui Seong;Lee, Jungbin;Yi, Jaeshin;Shin, Chee Burm;Choi, Je Hun;Lee, Seokbeom
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.344-348
    • /
    • 2009
  • One-dimensional modeling was carried-out to predict the capacity loss of a lithium-ion polymer battery during cycling. The model not only accounted for electrochemical kinetics and ionic mass transfer in a battery cell, but also considered the parasitic reaction inducing the capacity loss. In order to validate the modeling, modeling results were compared with the measurement data of the cycling behaviors of the lithium-ion polymer batteries having nominal capacity of 5Ah from LG Chem. The cycling was performed under the protocol of the constant current discharge and the constant current and constant voltage charge. The discharge rate of 1C was used. The range of state of charge was between 1 and 0.2. The voltage was kept constant at 4.2 V until the charge current tapered to 50 mA. The retention capacity of the battery was measured with 1C and 5C discharge rates before the beginning of cycling and after every 100 cycles of cycling. The modeling results were in good agreement with the measurement data.

Structural Performance and Behavior of Concrete Floating Container Terminal by Live Load Distributions (활하중 분포에 따른 콘크리트 부유식 컨테이너 터미널의 구조성능 및 거동)

  • Lee, Du-Ho;Jeong, Yun-Ju;You, Young-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • In this study, comparative analysis has been performed with regard to a bending stress and deformation at bottom slab of a concrete floating container terminal by live load distributions. In addition, a structural performance and behavior of the floating structure is considered using a numerical analysis. Through reviewed structural performance of a floating structure by live load distribution, the structure presented tensile behavior by two live load cases (A, B, D-type). Then, the other live load cases (C, E, F, G, H, I, J-type) shows compressive behavior. Especially, immoderately compressive stress was generated on bottom slab at specific load distribution. but, that should be decreased through controling buoyancy pre-flexion. Through reviewed structural behavior, slopes of structure by four live load cases (B, E, F, H-type) were exceeded in design criteria of mega-float. It should be estimated that it get out of the load case at loading container. In all, the present study can be considered as a benchmark of a floating container terminal in the absence of analysis and will be used to guide-line about serviceability of concrete floating container terminal.

Successful Renal Autotransplantation for the Treatment of Severe Renovascular Hypertension in a 14-year-old Boy (신 자가이식을 통한 14세 소년에서 발생한 심한 신성 고혈압의 성공적인 치료)

  • Ji, Min-Chul;Park, Se-Jin;Choi, Jae-Young;Ko, Young-Guk;Kim, Myoung-Soo;Kim, Ji-Hong;Shin, Jae-Il
    • Childhood Kidney Diseases
    • /
    • v.14 no.2
    • /
    • pp.223-229
    • /
    • 2010
  • Percutaneous transluminal renal angioplasty (PTRA) is the current treatment of choice for renal artery revascularization, but renal autotransplantation has been an alternative treatment for complex cases. Here we report a 14-year-old boy with severe hypertension successfully treated with PTRA and renal autotransplantation. Doppler ultrasonography and computed tomography (CT) angiography revealed slight narrowing in the right renal artery ostium and complete obstruction in the left renal artery ostium with multiple collaterals. PTRA with stent insertion was performed for the treatment of the right renal artery, but it was impossible for the left renal artery due to the total obstruction. Therefore, left nephrectomy for autotransplantation was done with the peritoneal approach and the left kidney was autotransplanted to the ipsilateral iliac fossa. Postoperatively, Doppler ultrasonography and mercapto-acetyl-triglycine (MAG-3) renogram were performed, which showed normal renal artery blood flow and kidney function. Blood pressure was normalized and anti-hypertensive drugs were gradually tapered. Fibromuscular dysplasia was suspected to be responsible for the renal artery stenosis based on clinical aspects. In conclusion, renal autotransplantation is also a good treatment option for children with severe renovascular hypertension when endovascular treatment has failed or is not possible.

A retrospective clinical study of survival rate of the ITI $TE^{(R)}$ implant (ITI $TE^{(R)}$ 임플란트의 생존율에 관한 후향적 임상 연구)

  • Suh, Hyun-Kee;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chai, Jung-Kyu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.673-682
    • /
    • 2006
  • Recent study shows that implant design has a great impact on initial stability in bone. The ITI $TE^{(R)}$ implant, designed originally for immediate placement has a tapered/ cylindrical form which fits the anatomical shape of the natural alvelous or tooth root. The increased diameter at the collar region coupled with more threads lead to more bone contact and enhanced stability. The aim of this retrospective study is to evaluate the clinical use and the efficacy of recently introduced ITI TE implant with a new macro-design. The following results are compiled from 139 patients who received ITl TE implant surgery at the periodontal department. of Yonsei University Hospital between July 2002 and September 2005. 1. 139 patients received 173 ITl $TE^{(R)}$ implants in their maxilla and mandible (Mx 82, Mn 91). Posterior area accounted for 84% of the whole implant surgery, 2. In the distribution of bone quality, type III(41,0%) was the most, followed by type IV(41,0%) and type II (27.7%). As for the bone quantity, type B(43.9%) was the most, followed by type C(42.2%), type D(12.2%) and type A(1.7%). 3. 125 implants(83.9%) were treated by single crown, which accounted for the majority. 4, The total implant survival rate was 100% after a mean follow-up period of 21.2 months. This preliminary data with ITl $TE^{(R)}$ implant showed excellent survival rate although the majority of implants evaluated in this study were placed in the posterior region of the jaw and compromised sites.