• Title/Summary/Keyword: tap water

Search Result 889, Processing Time 0.031 seconds

Detection and Distribution of the Pathogenic Bioagent Aeromonas (Gamma-Proteobacteria) in Water Supplies of Seoul (서울시 상수계통에서 병원성균 Aeromonas (감마-프로테오박테리아) 분포연구)

  • Lee, Eun-Sook;Lee, Mok-Young;Han, Sun-Hee;Ka, Jong-Ok
    • Korean Journal of Microbiology
    • /
    • v.43 no.2
    • /
    • pp.106-110
    • /
    • 2007
  • The detection and distribution of Aeromonas in water supplies were investigated by using the USEPA Method 1605. Water samples were collected from the Han River, finished waters and tap waters supplied from Water Treatment Plants in Seoul monthly from July 2002 to December 2003. Aeromonas species in each water sample were quantified based on the development of yellow colonies on the surface of membrane filter using a selective medium (Ampicillin-Dextrin Agar with Vancomycin). The Quality Control (QC) for this study met the acceptance criteria of Method 1605. The concentrations of Aeromonas species in surface water samples ranged from $1.0{\times}10^{0}\;to\;9.8{\times}10^{3}\;CFU/ml$. Aeromonas species were found only in one tap water sample with concentration of 1 CFU/500 ml. No Aeromonas species were found in any finished water samples. Aeromonas species detected here were identified as A. salmonicida(51%), A. caviae(4.7%), A. schubertti(3.4%), A. sobria(3.8%), A. hydrophila(2.1%), and A. ichithiosmia(0.4%). A. salmonicida was the dominant species, which is of no significance to human health. Chlorine resistance of A. salmonicida was evaluated and as a result, 99.99% of A. salmonicida decreased after 30 seconds exposure at residual free chlorine 0.2 mg/L. These suggest that the waters supplied in Seoul may be safe against the pathogenic agent Aeromonas.

An Examination Performed to Identify the Causative Agent of Crusian Carp (Carassius carassius) Mass Mortality in Jinyangho

  • Shin, Gee-Wook;Lee, Hu-Jang;Jung, Tae-Sung
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.4
    • /
    • pp.1-3
    • /
    • 2003
  • Jinyangho is a natural water supply source of tap water in west Gyeongnam area, but mass mortality of crusian carp occurred during the time of temperature rise in spring. Examinations on diseased fishes were able to isolate four bacteria isolates and then identified the bacteria as a member of Aeromonas sp. Challenge experiment with mirror carp (Gyrinus carpiospecilaris) was proved the virulence, the isolates were in turn believed as the causative agent of mass mortality in Jinyangho.

Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique (X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정)

  • Kim Seok;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF

Effective Ozone Generation from Hole Gaps in Water (공전극(孔電極)을 사용(使用)한 효과적(效果的)인 수중(水中) 오존발생(發生))

  • Moon, Jae-Duk;Kim, Jin-Gyu;Kim, Kee-Ung;Choi, Jung-Uk;Kim, Chang-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1625-1627
    • /
    • 1994
  • A potential to effective ozone generation for 4 kinds of gap, a hole-to-plate gap, a hole-to-hole gap, a hole-to-rod gap and a plate-to-plate gap in tap water has been investigated. It is found that the hole gaps indicated higher ozone generation compared to that of the plate-to-plate gap. As a result, the hole gaps could be an effective means to generate ozone in water by utilizing both of one generation mechanisms of the discharge and the electrolysis.

  • PDF

The Determination of Dissolved Total Fe by Flow Injection Analysis in Environmental Samples

  • Kim, Do Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin Sik
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.510-515
    • /
    • 2001
  • There has been an increasing need for analytical methods of dissolved total iron (tFe) that are highly sensitive, rapid, inexpensive and simple for environmental samples. A sensitive flow injection analysis (FIA) method for determining the concentration of tFe in environmental samples was developed. The proposed method required 10 minutes and only $500{\mu}L$ of sample for and analysis. The standard deviation was 5.0% at $0.5{\mu}gL^{-1}$ (n=6), and the detection limit was $0.075{\mu}gL^{-1}$. The developed method was applied to environmental samples such as tap water, mineral water, rain, snow and cloud water. Since this FIA system was free form interferences of coexisting ions commonly found in samples, sub-${\mu}gL^{-1}$ level of tFe could be easily determined without further preconcentration and separation.

  • PDF

Compositional and Morphological Analyses of Black Precipitate Formed on the Surface of Heating Appliance (수돗물 가열시 형성되는 흑색 침전물의 성분 분석)

  • Baek, Mi-Hwa;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.184-187
    • /
    • 2007
  • The compositional and morphological analyses have been carried out by employing XRD, EPMA, and SEM for the black-colored precipitate which is formed on the surface of heating appliances by heating tap water. XRD analysis has showed that the precipitate was mainly composed of calcium carbonate with a crystal structure of calcite. Also, small amounts of precipitate by SEM showed that the microscopic shape of the precipitate was usually angular spherical.

Preconcentration and Detection of Herbicides in Water by Using the On-line SPE-HPLC System and Photochemical Reaction

  • 이승호;이성광;박영훈;김현주;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1165-1171
    • /
    • 1999
  • The analysis of trace herbicides using the on-line SPE-HPLC system and a photochemical reaction was studied. 18 compounds of herbicides including eight triazines, six phenoxy acids and esters, and four other herbicides were examined. The on-line SPE-HPLC system developed for selection of eluting solvent improved chromatographic efficiency. The recoveries of herbicides were higher than 77%. With 100 mL tap water samples, the detection limits for all analytes were in the 0.1-2.3×10-10 M range. Detection was done by a UV or fluorescence spectrometer after photochemical reaction at the end of the column with 2W or 450W mercury lamp. Without a photochemical reaction, all compounds responded to 230 nm UV detector, but phenoxy acids and esters were weakly detected. However, with a photochemical reaction, these compounds were selectively detected at 320 nm wavelength of UV absorption and 400 nm emission of the fluorescence detectors. This method can be used for the analysis of environmental water containing herbicides at trace levels.

Experimenting biochemical oxygen demand decay rates of Malaysian river water in a laboratory flume

  • Nuruzzaman, Md.;Al-Mamun, Abdullah;Salleh, Md. Noor Bin
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.99-106
    • /
    • 2018
  • Lack of information on the Biochemical Oxygen Demand (BOD) decay rates of river water under the tropical environment has triggered this study with an aim to fill the gap. Raw sewage, treated sewage, river water and tap water were mixed in different proportions to represent river water receiving varying amounts and types of wastewater and fed in a laboratory flume in batch mode. Water samples were recirculated in the flume for 30 h and BOD and Carbonaceous BOD (CBOD) concentrations were measured at least six times. Decay rates were obtained by fitting the measured data in the first order kinetic equation. After conducting 12 experiments, the range of BOD and CBOD decay rates were found to be 0.191 to 0.92 per day and 0.107 to 0.875 per day, respectively. Median decay rates were 0.344 and 0.258 per day for BOD and CBOD, respectively, which are slightly higher than the reported values in literatures. A relationship between CBOD decay rate and BOD decay rate is proposed as $k_{CBOD}=0.8642_{k_{BOD}}-0.0349$ where, $k_{CBOD}$ is CBOD decay rate and $k_{BOD}$ is BOD decay rate. The equation can be useful to extrapolate either of the decay rates when any of the rates is unknown.

Microbial Quality and Safety of Fresh-Cut Broccoli with Different Sanitizers and Contact Times

  • Das, Basanta Kumar;Kim, Ji-Gang
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.2
    • /
    • pp.363-369
    • /
    • 2010
  • This study was conducted to investigate the effects of different sanitizers and contact times on storage quality and microbial growth in fresh-cut broccoli. Fresh broccoli samples were cut into small pieces, washed each for 90 s and 180 s in normal tap water (TW), $100\;{\mu}/l$ chlorinated water (CL, pH 7), electrolyzed water (EW, pH 7.2) containing $100\;{\mu}/l$ free chlorine, or $2\;{\mu}/l$ ozonated water ($O_3$). Then, samples were packaged in 30-${\mu}m$ polyethylene bags and stored at $5^{\circ}C$ for 9 days. No significant differences were observed in gas composition and color parameters ($L^*$, $a^*$, $b^*$, and hue angle) among different sanitizers with contact times. No off-odor was detected during the storage. A longer contact time was not effective in reducing microbial population, except with $O_3$ washing. $O_3$ with 90 s was not much effective in reducing microbial population compared with Cl or EW. However, samples washed with $O_3$ for 180 s observed the lowest numbers of total aerobic and coliform plate counts. The result suggested that, a longer contact time of ozone can be used as a potential sanitizer to maintain the microbial quality and safety of fresh-cut broccoli.

A study on the corrosion control of tap water by lime and carbon dioxide (소석회와 이산화탄소를 이용한 수돗물 부식성 제어에 관한 연구)

  • Cheong, Won-Suk;Kim, Jin-Keun;Park, Duk-Joon;Kim, Sun-Wook;Jeong, Sang-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.193-199
    • /
    • 2011
  • A method to improve internal corrosion control efficiency by adding lime and carbon dioxide, which, in turn increases the Langelier Index (LI) for filtered water at a conventional drinking water treatment plant (WTP) was investigated. The SJ WTP (Q=100,000 $m^{3}$/d) has been operating an internal corrosion control system since 2006. The system has achieved stable operation through technical development and trial and error over a period of several years. As a result of the operation, the LI of treated water has increased up to 29% by adjusting pH of filtered water to 7.8 with the addition of lime and carbon dioxide. Coupon tests in the distribution system indicated that the corrosion rate has been delayed by 24% when the internal corrosion method was implemented. The increase of LI by lime and carbon dioxide has been proven to be a practical method for controlling corrosion.