• Title/Summary/Keyword: tap water

Search Result 887, Processing Time 0.027 seconds

Carbon Emission Evaluation of Tap Water (수돗물의 탄소 배출량 평가)

  • Kim, Jin-Keun;Jeon, Hong-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.511-517
    • /
    • 2011
  • To evaluate carbon emission in water treatment processes, LCA (life cycle assessment) was applied to 8 multi-regional water treatment plants (WTPs) from intake to supply of tap water. Investigation of 8 WTPs revealed that average carbon emission for 1 $m^3$ of tap water was 221 g. Major carbon emission sources in water supply system were intake and supply processes. Meanwhile, mixing process was the main carbon emission source in unit water treatment processes. Carbon emission was proportional to the turbidity and COD of raw water. Intake of better raw water and minimization of energy consumption in unit processes are needed to reduce carbon emission in the WTPs. In addition, comparison of carbon emission among WTPs can be used as a parameter for optimization of operation and maintenance of water treatment processes.

Antibacterial Effect of Electrolyzed Water on Oral Bacteria

  • Lee Sung-Hoon;Choi Bong-Kyu
    • Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.417-422
    • /
    • 2006
  • This study investigated the antibacterial effect of electrolyzed water on oral bacteria both in vitro and in vivo. Tap water was electrolyzed in a water vessel using platinum cell technology. The electrolyzed tap water (called Puri-water) was put in contact with five major periodontopathogens or toothbrushes contaminated with these bacteria for 30 sec. In addition, Puri-water was used as a mouthwash for 30 sec in 16 subjects and the antibacterial effect on salivary bacteria was evaluated. Puri-water significantly reduced the growth of all periodontopathogens in culture and on toothbrushes, and that of aerobic and anaerobic bacteria in saliva, when compared to the effect of tap water. It also significantly reduced mutans streptococci growing on mitis salivarius-bacitracin agar. Our results demonstrate that the electrolyzed tap water is effective as a mouthwash and for toothbrush disinfection.

The Determinants of Tap Water Consumption Patterns (수돗물 음용행동의 영향변수에 관한 연구)

  • Kim Young-Seen
    • Journal of Families and Better Life
    • /
    • v.24 no.2 s.80
    • /
    • pp.93-106
    • /
    • 2006
  • This study investigated the determinants of Tap Water consumption patterns. Socio-demographic variables(gender, family income, education level, residual area) and consumer attitude knowledge(confidence, knowledge, problem experience, risk perception and aesthetic satisfaction)were included in the analysis. Three hundred fifty-nine teachers were participated in this study. ANOVA(Scheffe test), t-test, regression and logistic regression were conducted. The results of this study are as follows: 1. Tap water was consumed by only 1.7%, boiled water prior to drinking by 37.9%, water filtered by 39.8% and bottled water by 19.0%. 2. Consumer attitude knowledge was affected by socio-demographic variables. That is, aesthetic satisfaction was affected by age, risk perception by gender and educational level, confidence by educational level, knowledge by gender and age, and problem experience by age. 3. Logistic regression analysis indicated that age, confidence and aesthetic satisfaction were the determinants of bottled water or filtered water choice. However, risk perception was not a significant determinant. This suggests alternatives to tap water is related to non-risk, or non-safety factors.

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

A Study on the Design of water Hydraulic Systems Based on Characteristics of Tap-Water (수압 특성 연구를 기초로 한 수압시스템의 설계에 관한 연구)

  • Yun, Young-Won;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1322-1331
    • /
    • 2004
  • This paper presents studies on the design of water hydraulic system and components to replace oil with tap-water as the pressure transmission medium in hydraulic systems. In order to improve the performance of water hydraulic system, the thermal and hydraulic properties of tap-water are first investigated. Based on these characteristics, the design parameters, such as the clearances of the moving parts, the cross-sectional area of pipes and relative roughness, are proposed so that the performance of water hydraulic system is the same as that of oil. In addition, the operating ranges, which show the possibility of using water hydraulic system, are examined.

The Effect of Ingesting Small and Large Amount of Tap or Iced Water on Circulation of Normal Men (소량과 다량의 맹물 및 얼음물 섭취가 정상인의 순환에 미치는 영향)

  • 최명애;김종임
    • Journal of Korean Academy of Nursing
    • /
    • v.17 no.2
    • /
    • pp.116-121
    • /
    • 1987
  • This study was undertaken to elucidate effects of ingesting small or large amount of tap or iced water on circulation of normal healthy men with the purpose of furnishing basic data for nursing intervention of myocardial infarction patients. The subjects for this study were normal healthy men consisting of 30men and 30women in age from 22 to 30 years. One group consisting of 30men drank 240m1 tap water on day l and 240m1 iced water 24hours later. The other group drank 960m1 tap water on day 1 and 960m1 iced water 24hours later. Blood pressure and heart rate were taken in a sitting position before ingesting water, and immediately after ingesting it and at 2,5,10,15,30 minute intervals thereafter. Changes of heart rate, systolic and diastolic blood pressure after ingesting water were compared with those of preingestive period. The results obtained were as follows : 1. There were no significant changes in blood pressure and heart rater after ingesting small amount of water regardless of its temperature. 2. No significant decrease in blood pressure after ingesting large amount of tap water at all time peroids was noted. 3. A strongly significant interaction effect bet-ween temperature and volume was demonstrated, that is, there was a highly significant decrease in blood pressure and heart rate at all time periods after ingesting large amount of iced water.

  • PDF

A study on Availability of Magnetic treatment water as a cooking water (조리용수로써 자화수의 기능성에 관한 연구 -건조물의 수화능력을 중심으로-)

  • Jang, Jeong-Ock;Lee, Young-Mee
    • Journal of the Korean Society of Food Culture
    • /
    • v.11 no.1
    • /
    • pp.37-42
    • /
    • 1996
  • We have studied specific properties of magnetic treated water as processing water will make different cookery form the case of piped tap water. The result is as follows; The magnetic treated water both from tap water and pure water became more alkaline than not-magnetic treated water in pH change. As time goes on, magnetic treated or not, pH reduced considerably in piped tap water and increased in pure water. The magnetic treated water showed higher hydration rate than piped tap water in hydration of dried food. According to time, difference of hydration between tap water group and magnetic-treatment water group became significantly. Surface tension of magnetic treated water was slightly lower than that of piped tap water. And it reduced considerably with time. The magnetic treated water showed significantly effective outflow of salt especially in initial phase of soaking in salt-in food.

  • PDF

Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan (수도관 부식에 대한 잔류염소 농도 영향 및 부식제어 방안)

  • Han, Keum-Seok;Park, Ju-Hyun;Park, Young-Bok;Kim, Seong-Jae;Kim, Hyen-Don;Choi, Young-June;Choi, In-cheol;Hong, Seong-Ho
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • Langelier Index (LI) is used as a tap water corrosiveness index. Residual chlorine in tap water induces corrosion inside water pipes. This study takes a deeper look into the effect of residual chlorine in water pipes. Comparison between tap waters of Y and K water treatment plant (WTP) shows that the LI index of K WTP is lower than that of Y. However, the corrosion rate of Y WTP is higher than that of K WTP. This means that the higher the concentration of residual chlorine in tap water, the higher the corrosion rate of pipe materials. When calcium hydroxide was added to tap water, the corrosiveness index was improved and thus the corrosion rate reduced. It is possible to increase the disinfection efficiency by increasing the duration of residual chlorine and suppressing the rust generation of water pipes and to supply minerals. A guideline for corrosion control with residual chlorine should be set up. The effects of residual chlorine should be included in the corrosiveness index of tap water.

Comparison of Household Trihalomethanes (THMs) Exposure Associated with Use of Municipal Tap Water Treated with Chlorine or Ozone-Chlorine (염소살균과 오존-염소살균 수도수의 사용과 관련한 가정 트리할로메탄 노출 비교평가)

  • Jo, Wan Geun;Gwon, Gi Dong;Dong, Jong In;Jeong, Yong
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.627-635
    • /
    • 2004
  • Evaluated were household THMs exposure associated with the use of municipal tap water treated with chlorine and with ozone-chlorine. The current study measured the THMs concentrations in the tap water and indoor and outdoor air in the two types of household, along with an estimation of THMs exposure from water ingestion, showering, and the inhalation of indoor air. Chloroform was the most abundant THMs in all three media, yet no bromoform was detected in any sample. Contrary to previous findings, the fall water THMs concentrations exhibited no significant difference between the chlorine and ozone-chlorine treated water. However, the spring median chloroform concentration in the tap water treated with chlorine (17.6 ppb) was 1.3 times higher than that in the tap water treated with ozone-chlorine (13.4 ppb). It is suggested that the effects of the water parameters should be considered when evaluating the advantage of ozone-chlorine disinfection for THMs formation over chlorine disinfection. The indoor air THMs concentration trend was also consistent with the water concentration trend, yet the outdoor air THMs concentrations did not differ significantly between the two types of household. The indoor to outdoor air concentration ratios were comparable with previous studies. The THMs exposure estimates from water ingestion, showering, and the inhalation of indoor air suggested that, for the residents living in the surveyed households, their exposure to THMs in the home was mostly associated with their household water use, rather than the indoor air. The THMs exposure estimates from tap water ingestion were similar to those from showering.

Improvement of sampling method for bacteriological test in tap water (수도꼭지에서 미생물 검사 목적의 샘플링 방법 개선 연구)

  • Lee, Eun-Sook;Lee, Dong-Sik;Lee, Mok-Young;Lee, Man-Ho;Han, Sun-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.519-525
    • /
    • 2011
  • We studied on the effect of faucet cleanliness, faucet conditions (screen, mixing faucet), and flushing time for bacterial detection in tap water. As results, tap water should be left to run to waste for 2 to 3 minutes and if a questionable cleanliness is questionable, disinfect the faucet by using flaming or other methods before sampling. We proposed sampling method to decrease effect of factors associated with bacterial detection in tap water and contributed to be evaluated more accurate water quality.