Effects of Water Aggressivity on the Corrosion in Water Distribution Systems (물의 침식성이 수도관 부식에 미치는 영향)

  • Kwak, Phill Jae;Kim, Sun Il;Woo, Dal Sik;Nam, Sang Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.134-139
    • /
    • 1999
  • This study was conducted to determine the effects of water aggressivity on the corrosion in a recirculating pipe loop systems. As the pH was increased in the range of pH 6.0~8.5, water aggressivity was decreased. Zine and iron concentration of water adjusted by pH were lower than those of tap water and water adjusted by alkalinity and calcium hardness. The major elements of corrosion deposit analyzed by EDS(Energy Dispersion Spectrophotometer) were zinc and calcium. In conclusion, we suggest that in corrosion control practice in the water works industry, increasing the pH of the water can serve as a way of controlling the solubility of metal ions release from water distribution systems.

  • PDF

Manganese treatment to reduce black water occurrence in the water supply

  • Kim, Jinkeun
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.230-236
    • /
    • 2015
  • 26 multi-regional water treatment plants (WTPs) were investigated, to determine the characteristics of manganese (Mn) concentration and removal in Korea. Mn concentrations of raw water in most WTPs were higher than the drinking water standard (i.e., 0.05 mg/L); thus, proper removal of Mn at the WTPs is needed. Mn concentration was generally higher in lakes than rivers due to seasonal lake turnovers. The Mn concentrations of treated water at 26 WTPs in 2012 were less than 0.05 mg/L, due to strict law enforcement and water treatment processes optimization. However, before 2010, those concentrations were more than 0.05 mg/L, which could have led to an accumulation of Mn oxides in the distribution system. This could be one of the main reasons for black water occurrence. Therefore, regular monitoring of Mn concentration in the distribution system, flushing, and proper Mn removal at WTPs are needed, to supply clean and palatable tap water.

The Effects of Polyphosphate Corrosion Inhibitor and Lime Water to Reduce Red Water for Carbon Steel (탄소강의 녹물저감에 대한 인산염부식억제제와 석회수 효과 연구)

  • Park, Young-Bog;Kong, Sung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.228-237
    • /
    • 2005
  • The main purpose of this study was to investigate the red water reducing effects of phosphate based inhibitor when it was applied to water distribution system. The effects of pH, alkalinity, calcium concentration in the reduction of the red water also studied. The most finished water in Korea showed relatively high corrosiveness and was required to introduce some types of corrosion reducing methods such as addition of alkalinity. The precipitation of $CaCO_3$ by addition of $Ca(OH)_2$ formed porous film on the surface of the carbon steel pipes and was displaced easily from the surface of the pipes; on the other hand, addition of zinc phosphate (ZOP) formed reliable film on the surface and reduced iron release and color. Although the main function of ZOP was to suppress the release of Pb and Cu, it also reduced iron concentration released from water distribution pipes.

Assessment of Variable Characteristics in Water Quality of the Supply Systems in the Building (건축물내 급수설비의 수질변화 특성과 영향력 평가)

  • Lee, H.D.;Hwang, J.W.;Bae, C.H.;Kim, S.J.
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.313-320
    • /
    • 2004
  • In this study, variable characteristics of drinking water and the influences on underground water reservoirs, rooftop water tanks, and service water pipes in the building were assessed. The influence of underground water reservoir material and water capacity on water quality also were assessed. The results are the following as; First of all, the drinking water passing through underground water reservoirs or service water pipes in the building, averagely metal component concentration more increased from percent of 41.3 to percent of 74.2 totally than other items of water quality. On the other hand, both residual chlorine and total solid highly decreased 65.6 percent and 35.3 percent, respectively. Therefore, it was thought that water quality could be getting worse for microorganism re-growth by residual chlorine reduction, and total solid also could be a cause for extraneous matters accumulated in water reservoir. Secondly, the variations on water quality of each stage for water supply system in the building were higher in water service pipes connected from rooftop water tanks to the tap than in underground water reservoirs. In addition to, among of twelve items on water quality, ten items on water quality except dissolved oxygen and residual chlorine increased. Therefore, it was thought that the influence of water service pipes connected from rooftop water tanks to the tap on water quality were higher than other stages of water supply system in the building. Thirdly, in case of materials of underground water reservoir, it was likely that the variation on water quality by stainless steel and concrete materials got some similar. In case of water capacity, the variations on water quality of underground water reservoirs over $1,000m^3$ higher than those under $1,000m^3$. That reasons was likely that the retention time(49.72 hours averagely) of underground water reservoirs over $1,000m^3$ was two times longer than it of those under $1,000m^3$(23.37 hours). Therefore, it was thought that the influence on water quality by materials were some similar, but in case of water capacity, the influence of underground water reservoirs were higher.

Effect of intracanal medications on the interfacial properties of reparative cements

  • Pereira, Andrea Cardoso;Pallone, Mariana Valerio;Marciano, Marina Angelica;Cortellazzi, Karine Laura;Frozoni, Marcos;Gomes, Brenda P.F.A.;de Almeida, Jose Flavio Affonso;de Jesus Soares, Adriana
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.21.1-21.8
    • /
    • 2019
  • Objectives: The purpose of the present study was to evaluate the effect of calcium hydroxide with 2% chlorhexidine gel (HCX) or distilled water (HCA) compared to triple antibiotic paste (TAP) on push-out bond strength and the cement/dentin interface in canals sealed with White MTA Angelus (WMTA) or Biodentine (BD). Materials and Methods: A total of 70 extracted human lower premolars were endodontically prepared and randomly divided into 4 groups according to the intracanal medication, as follows: group 1, HCX; group 2, TAP; group 3, HCA; and group 4, control (without intracanal medication). After 7 days, the medications were removed and the cervical third of the specimens was sectioned into five 1-mm sections. The sections were then sealed with WMTA or BD as a reparative material. After 7 days in 100% humidity, a push-out bond strength test was performed. Elemental analysis was performed at the interface, using energy-dispersive spectroscopy. The data were statistically analyzed using analysis of variance and the Tukey test (p < 0.05). Results: BD presented a higher bond strength than WMTA (p < 0.05). BD or WMTA in canals treated with calcium hydroxide intracanal medications had the highest bond strength values, with a statistically significant difference compared to TAP in the WMTA group (p < 0.05). There were small amounts of phosphorus in samples exposed to triple antibiotic paste, regardless of the coronal sealing. Conclusions: The use of intracanal medications did not affect the bond strength of WMTA and BD, except when TAP was used with WMTA.

Study on the erosion-corrosion damages of pump impeller (워터펌트 내에 있는 임펠러의 침식.부식에 관한 연구)

  • Kim, Jae-Wook;Lim, Hee-Chang;Lim, Uh-Joh
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.102-107
    • /
    • 2007
  • The steel impeller placed in a water pump has been studied with the aim to understand corrosion phenomena on the surface responsible for reducing the pumping efficiency of water inside cooling system. This preliminary experiment includes a period (around 1 month) observation with a powered microscope and weight measurements. The experiments are carried out at different conditions of water and mixtures of water and coolants, based on the water contents of 25%, 50%, 75%, and 100% water (pure tap water). From the visual results of microscopy, most of the steel surface is fitted and clear rusty or corrosion phenomena are noticeable as time goes. In addition, the weight loss of the sample specimen submerged in the water is linearly increased, whereas those in the mixtures of water initially gain weight and become almost constant.

  • PDF

Current Status of Drinking Water Treatment and its Countermeasure (국내외 정수처리 기술의 현황)

  • 류재근
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.67-92
    • /
    • 1997
  • Tap water should be shown the complexity of measures neccessary to secure water quality, especially with respect to drinking and bathing. Designated reservoirs Paldang and Daechung as the Special Environment Protection Areas to regulate new pollution sources and to facilitate construction of wastewater treatment facilities. In this country, 91% of total drinking water resource, consist of 66% stream water, 25% dam water, 7% dune flitrate, 1% each of spring and ground water, are from the surface water. The total volume of annual mean water resources due to precipitation. Over 8% of the total resources are class III as shown in the table., eapecially the water quality of downstream of Nakdong and Yeongsan river are getting worse due to continued economic and social development.

  • PDF

Study on $NH_4H_2PO_4$ in nutrient solution using tap water for water supply during hydroponic raising of crisp lettuce (수돗물을 용수로 사용한 결구상추의 수경육묘시 배양액내 $NH_4H_2PO_4$에 관한 연구)

  • 김주희;김혜진;김영식
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1995.04a
    • /
    • pp.75-78
    • /
    • 1995
  • 양액재배시 배양액의 pH는 중요한 재배인자이며, 이는 용수의 성질에 따라 큰 영향을 받는다. 용수로는 지하수를 많이 사용하나, 수돗물을 사용하는 경우도 흔히 있다. 수돗물은 pH가 7.5 정도로, pH가 낮은 용수를 사용할 경우와 같은 조성의 배양액을 조제하면 배양액의 pH가 높아 생육에 나쁜 영향을 끼친다. 따라서, 용수의 성질에 따라 배양액의 조성을 달리하여 pH를 적정수준으로 유지하는 것이 중요하다. (중략)

  • PDF