• Title/Summary/Keyword: tap water

Search Result 889, Processing Time 0.021 seconds

Measuring the Economic Benefits of the Tap Water Quality Improvement in Ulsan (울산시 수돗물 수질개선의 편익 추정)

  • Kwak, So-Yoon;Yoo, Seung-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • This paper attempts to measure the economic benefits of tap water quality improvement using a specific case study of Ulsan, one of the large cities in Korea. To this end, we apply the contingent valuation (CV) method by employing a one-and-one-half bounded spike dichotomous choice question format. We surveyed a randomly selected sample of 400 households in Ulsan and asked respondents questions in person-toperson interviews about how they would willing to pay for the program. Respondents overall accepted the contingent market and were willing to contribute a significant amount (1,611 won), on average, per household per month. This willingness varies according to individual characteristics such as education level and income. The aggregate value of the program in Ulsan amounts to approximately 8 billion won per year.

Discrimination of the drinking water taste by potentiometric electronic tongue and multivariate analysis (전자혀 및 다변량 분석법을 활용한 먹는물의 구별 방법)

  • Eunju Kim;Tae-Mun Hwang;Jae-Wuk Koo;Jaeyong Song;Hongkyeong Park;Sookhyun Nam
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.425-435
    • /
    • 2023
  • Organoleptic parameters such as color, odor, and flavor influence consumer perception of drinking water quality. This study aims to evaluate the taste of the selected bottled and tap water samples using an electronic tongue (E-tongue) instead of a sensory test. Bottled and tap water's mineral components are related to the overall preference for water taste. Contrary to the sensory test, the potentiometric E-tongue method presented in this study distinguishes taste by measuring the mineral components in water, and the data obtained can be statistically analyzed. Eleven bottled water products from various brands and one tap water from I city in Korea were evaluated. The E-tongue data were statistically analyzed using multivariate statistical tools such as hierarchical clustering analysis (HCA), principal component analysis (PCA), and partial least squares discriminant analysis (PLS-DA). The results show that the E-tongue method can clearly distinguish taste discrimination in drinking water differing in water quality based on the ion-related water quality parameters. The water quality parameters that affect taste discrimination were found to be total dissolved solids (TDS), sodium (Na+), calcium (Ca2+), magnesium (Mg2+), sulfate (SO42-), chloride (Cl-), potassium (K+) and pH. The distance calculation of HCA was used to quantify the differences between 12 different types of drinking water. The proposed E-tongue method is a practical tool to quantitatively evaluate the differences between samples in water quality items related to the ionic components. It can be helpful in quality control of drinking water.

Evaluation of Stored Rainwater Quality at Galmoe Middle School Rainwater Harvesting System (갈뫼중학교 빗물이용시설에서의 저장 빗물수질평가)

  • Han, Moo-Young;Lee, Soon-Jai
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • One of the major obstacles confronted in promoting the rainwater harvesting is the concerns of acid rain and heavy metals. Although there are many data concerning the quality of rainwater precipitation for the study of acid rain, the study on the quality of stored rainwater has been limited. In this study, we monitored the quality of stored rainwater at Galmoe middle school, where a rainwater harvesting system is installed and in use for more than two years. We measured water quality parameters such as pH, Electro Conductivity(EC), Dissolved Oxygen(DO), and some metals (aluminium (Al), chromium(Cr), manganese(Mn), zinc(Zn), copper(Cu), arsenic(As), cadmium(Cd), lead(Pb)). The monitoring period was during one year from September 9th 2003 to August 5th 2004. It was observed that the average pH of stored rainwater is neutral. DO is similar to tap water and EC is lower than tap water. Metal Concentrations are within the concentration specified in Drinking Water Quality Standard. Overall, the stored rainwater quality is good enough for sundry use and there's no threat of acid rain and air pollution, if the rainwater harvesting system is well designed and maintained.

Evaluation of Water Quality using ICR Mouse 1-cell Embryo (ICR계 생쥐 1세포배를 이용한 수질의 평가)

  • Kim, Chung-Hyon;Cheong, Kyung-Soon;Park, So-Hyun;Hwang, Do-Yeong;Kim, Ki-Chul;Min, Eung-Gi
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.63-68
    • /
    • 1994
  • To confirm the overcome of in vitro 2-cell block, ICR mouse I-cell embryos were cultured in CZB media. All embryos in CZB were overcome in vitro 2-cell block and 92% of embryos were developed to the blastocyst at day 4. However, in m-KRB group(control) only 20% of embryos were developed over 2-cell. Any embryos in m-KRB did not develop to the morular stage. Developments and degenerations of ICR mouse I-cell embryos were compared in CZB medium prepared with water of three quality:(l) Milli-Q ultrafiltration water(UF);(2) Milli-Q reverse osmosis water(RO);(3) tap water(TAP). The objective was to evaluate the potential of quality control using ICR mouse 1-cell embryos. The more water was purified, the better embryo developments were supported and the less embryos were degenerated. As a quality control system, the culture of ICR 1-cell mouse embryos in CZB was useful.

  • PDF

A Study on THMs Formation in Service Waters and Waste Waters at Kunsan (군산지역 용 . 폐수중의 THMs생성 및 배출에 관한 연구)

  • 황갑수;이영남;김강주;여성구;김진삼
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.41-46
    • /
    • 2001
  • Trihalomethane(THMs) levels in drinking tap water, indoor swimming pool water and industrial effluent in Kunsan area were surveyed in this study. During experimental period, the monthly averages of THMs in drinking tap water from Keumkang wide-area supply ranged from 15$\mu\textrm{g}$/ι/to 50 $\mu\textrm{g}$ showing the highest level in summer. 3 indoor swimming pools showed the monthly average levels of THMs formation ranging from 8$\mu\textrm{g}$/ι/to 20$\mu\textrm{g}$/ι and the pool under public management seemed to maintain its water quality more stable than those under private management THMs concentrations in the effluents. discharged from 10 manufacturing companies, ranged from N.D. to 95$\mu\textrm{g}$/ι and it was estimated that the overall THMs level discharged front those manufacturing companies is not high, reflecting the traces recorded for most effluents. The composition ratios of individual THMs for industrial effluents showed a difference from those for drinking water and swimming pool water, along with their wide variations according to the company and relatively high composition ratios of Br substituents.

  • PDF

Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger (급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구)

  • Jeong, Dong-Hwa;Kim, Joo-Wan;Baik, Young-Jin;Lee, Young-Soo;Chung, Dae-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

Evaluation of Calcium Carbonate Saturation Indices in Water (상수 원수 수질의 탄산칼슘 포화지수 평가)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.130-135
    • /
    • 2007
  • In order to examine the corrosiveness of tap water, we studied methods calculating various indices including calcium carbonate saturation indices, using RTW model and LPLWIN model. Indices such as LI, RI and AI could be computed using the RTW model, whereas the LPLWIN model could find indices as LI, LR and CCPP. With water quality data obtained from tap water of Han River and Nak-Dong River watersheds, based on the indices found from the models, the water quality of the Nak-Dong River is better than that of Han River in the point of resisting corrosiveness. Further, the water quality of winter is highly corrosive than that of summer, as long as the temperature rises up, the corrosiveness is reduced.

  • PDF

Water Properties of Electrolytic Machine by Stainless Diaphragm and Effects of Electrolytic Ice Water Storage For Keeping Freshness of Squid, Todarodes pacificus (스테인레스 극판을 이용한 전해수장치의 수질특성과 오징어 선도유지를 위한 전해수 빙장 효과)

  • Lee, Nahme-Gull
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.293-301
    • /
    • 2006
  • This study was undertaken to prolonging the freshness in Squid(Todarodes pacificus) on the effects of ice storage methods(tap water ice, electrolytic water ice) using stainless diaphragm electrolytic instrument and also test an efficiency of instrument. Basically, stainless diaphragm electrolytic instrument studied for changes of pH on difference water flow and ampere. The lower water flower and higher ampere made low pH on acid part of electrolytic instrument. Squid samples were stored in tap water ice, acid part of electrolytic water and base part of electrolytic water and used in studying the changes of VBN and skin color through storage. Acid water had strong sterilization effects and VBN was lower levels of acid water than the others. Base water had not sterilization effects. Tap water ice storage was more sterilizing effects than base water ice storage but less effects than acid water ice storage. Lightness of Squid skin showed getting decrease at storage of ice water of all storage methods but acid water ice storage showed more retarding than the other two storage. From these results, it could be suggested that acid electric water ice storage is effective in extendance the shelf-life of squid at chilled storage.

The Analysis of Perchlorate in Nakdong River and Tap Water (낙동강 수계 및 수돗물에서의 Perchlorate($ClO_4^-$) 분석)

  • Kim, Hwa-Bin;Oh, Jeong-Eun;Lee, Sung-Yun;Cho, Jae-Weon;Snyder, Shane
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.776-781
    • /
    • 2006
  • Perchlorate ion($ClO_4^-$), which is present in the solid propellant for rocket, herbicide and some fertilizers. Perchlorate inhibits iodide uptake by the human thyroid gland. Impairment of thyroid function in expectant mothers may impact the fetus and result in effects including cerebral palsy, give rise to thyroid gland cancer. The US EPA(Environmental Protection Agency) adopted a reference dose(RfD) for perchlorate 0.0007 mg/kg-day, and this guidance lead to a Drinking Water Equivalent Level(DWEL) of 24.5 ${\mu}g/L$. The studies about perchlorate are actively performed in foreign countries, especially in USA but there is no study which surveyed the perchlorate contamination in Korea. Therefore, this study was done to investigate perchlorate contamination in Nak-dong river and tap water. The perchlorate was detected in Nakdong river and ranged from ND to 278.4 ${\mu}g/L$. The highest concentration was observed in Kumichon. The perchlorate concentration was decreased with the down stream of Nakdong river. The perchlorate concentration in tap water was varied with the cities and the concentration levels were $ND{\sim}34.1$ ppb. The highest perchlorate concentration was observed in DalsuGoo in Daegu and the similar concentration($9{\sim}11$ ${\mu}g/L$) was detected in most of the districts in Busan. The result of this study suggests that there is a perchlorate source near the Nakdong river and the urgent policy is needed to control perchlorate for the cities which are supplied from Nakdong river as for their tap water.