• Title/Summary/Keyword: tap

Search Result 1,812, Processing Time 0.028 seconds

The Monitoring of Corrosive Water Quality in Water Distribution System by Corrosion Characteristics of Raw and Tap water (원·정수의 부식특성에 따른 상수관망에서의 부식성 수질 모니터링)

  • Bae, Seog-Moon;Kim, Do-Hwan;Son, Hee-Jong;Choi, Dong-Hoon;Kim, Ik-Sung;Kim, Kyung-A
    • Journal of Environmental Science International
    • /
    • v.24 no.7
    • /
    • pp.907-915
    • /
    • 2015
  • The tap water is generally known to be corrosive in the pH range at 6.5 ~ 7.5. And the degree of corrosion varies depending on the types of raw water such as river surface water or lake water of the dam. Although several corrosion index represents the corrosivity of tap water, the typical corrosion indexes such as Langelier saturation index (LI) and calcium carbonate precipitation potential (CCPP) were calculated to monitoring the corrosive water quality about raw and tap water in water distribution system. To control the corrosive water quality, the correlation between corrosion index and water quality factors were examined. In this study, corrosion index (LI, CCPP) and the pH was found to be most highly correlated.

The Determinants of Tap Water Consumption Patterns (수돗물 음용행동의 영향변수에 관한 연구)

  • Kim Young-Seen
    • Journal of Families and Better Life
    • /
    • v.24 no.2 s.80
    • /
    • pp.93-106
    • /
    • 2006
  • This study investigated the determinants of Tap Water consumption patterns. Socio-demographic variables(gender, family income, education level, residual area) and consumer attitude knowledge(confidence, knowledge, problem experience, risk perception and aesthetic satisfaction)were included in the analysis. Three hundred fifty-nine teachers were participated in this study. ANOVA(Scheffe test), t-test, regression and logistic regression were conducted. The results of this study are as follows: 1. Tap water was consumed by only 1.7%, boiled water prior to drinking by 37.9%, water filtered by 39.8% and bottled water by 19.0%. 2. Consumer attitude knowledge was affected by socio-demographic variables. That is, aesthetic satisfaction was affected by age, risk perception by gender and educational level, confidence by educational level, knowledge by gender and age, and problem experience by age. 3. Logistic regression analysis indicated that age, confidence and aesthetic satisfaction were the determinants of bottled water or filtered water choice. However, risk perception was not a significant determinant. This suggests alternatives to tap water is related to non-risk, or non-safety factors.

Performance Analysis of Coding According to the Interpolation filter in Inter layer Intra Prediction of H.264/SVC (H.264/SVC의 계층간 화면내 예측에서 보간법에 따른 부호화 성능 분석)

  • Gil, Dae-Nam;Cheong, Cha-Keon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.225-227
    • /
    • 2009
  • International standard specification, H.264/SVC improved from H.264/AVC, is set up so as to promote free use of huge multimedia data in various channel environments.;H.264/AVC is a international standard speicification for video compression, adopted and commercialized as standard for DMB broadcasting by JVT of ISO/IEC MPEG and ITU-T VCEG. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding. Among prediction technologies, 'inter-layer intra prediction' is to use co-located block of up sampled sublevels as a prediction signal. At this time, application of interpolation is one of the most important factors to determine encoding efficiency. SVC's currently using poly-phase FIR filter of 4-tap and 2-tap respectively to luma components. This paper is written for the purpose of analyzing encoding performance according to the interpolation. For this purpose, we applied poly-phase FIR filter of '2-tap', '4-tap' and '6-tap' respectively to luma components and then measured bit-rate, PNSR and running time of interpolation filter. We're expecting that the analysis results of this paper will be utilized for effective application of interpolation filter. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding.

  • PDF

A study on the drinking water for some primary school in Seoul (서울지역 일부 국민학교의 음용수 이용에 관한 연구)

  • Lee, Won-Myo;Bang, Hyeong-Ae
    • Journal of the Korean Dietetic Association
    • /
    • v.1 no.1
    • /
    • pp.31-42
    • /
    • 1995
  • The aims of this study are to enhance the students' knowledge of the drinking water and its reliability by investigating drinking water situation and the degree of students' knowledge on the drinking water. The results are as follows 1. Status and drinking behavior about school drinking water (1) 97.53% of the schools are using the tap water as the resource of drinking water (2) 46 schools are in possession of water tank and 18 schools of them are using the water tank as the resource of drinking water. The cleaning and sanitization of the tank are carried out once in a year with hypochloronatrium by the low-level officials, nurse teachers, and dietitian. 2. The degree of students' knowledge about drinking water (i) This survey represent that students favor the spring water best and think the tap water worst for drinking. (2) 83% of the students think that the tap water is polluted and these conception are formed mostly by the mass communication. 80% of boys and 90% of girls answered they don't drink plain tap water.

  • PDF

The Effect of Ingesting Small and Large Amount of Tap or Iced Water on Circulation of Normal Men (소량과 다량의 맹물 및 얼음물 섭취가 정상인의 순환에 미치는 영향)

  • 최명애;김종임
    • Journal of Korean Academy of Nursing
    • /
    • v.17 no.2
    • /
    • pp.116-121
    • /
    • 1987
  • This study was undertaken to elucidate effects of ingesting small or large amount of tap or iced water on circulation of normal healthy men with the purpose of furnishing basic data for nursing intervention of myocardial infarction patients. The subjects for this study were normal healthy men consisting of 30men and 30women in age from 22 to 30 years. One group consisting of 30men drank 240m1 tap water on day l and 240m1 iced water 24hours later. The other group drank 960m1 tap water on day 1 and 960m1 iced water 24hours later. Blood pressure and heart rate were taken in a sitting position before ingesting water, and immediately after ingesting it and at 2,5,10,15,30 minute intervals thereafter. Changes of heart rate, systolic and diastolic blood pressure after ingesting water were compared with those of preingestive period. The results obtained were as follows : 1. There were no significant changes in blood pressure and heart rater after ingesting small amount of water regardless of its temperature. 2. No significant decrease in blood pressure after ingesting large amount of tap water at all time peroids was noted. 3. A strongly significant interaction effect bet-ween temperature and volume was demonstrated, that is, there was a highly significant decrease in blood pressure and heart rate at all time periods after ingesting large amount of iced water.

  • PDF

Electrochemical Corrosion Damage Characteristics of Alumium Alloy and Stainless Steel with Sea Water Concentration (알루미늄 합금 및 스테인리스강의 해수 농도 변화에 따른 전기화학적 부식 손상 특성)

  • Park, Il-Cho;Kim, Young-Bok;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.4
    • /
    • pp.259-265
    • /
    • 2017
  • 5000 series aluminium alloys and austenitic stainless steels have excellent corrosion resistance and sufficient strength, which are widely used as materials for marine equipment and their parts in the marine environment. The corrosion characteristics of materials are important factors for selecting the appropriate material due to fluid component changes in the estuarine and coastal areas where seawater and fresh water are mixed. Therefore, for 5083 Al alloy, STS304 and STS316L widely used in the marine environment, anodic polarization experiments were performed to compare the corrosion damage characteristics of each material by three kinds of solutions of 100 % tap water, 50 % tap water+50 % natural seawater and 100 % natural seawater. As a result of the anodic polarization experiments, aluminum alloy (5083) caused locally corrosion on the surface in the tap water, and corrosion damage occurred all over the surface when the seawater was included. Stainless steels (STS304 and STS316L) presented almost no corrosion damage in tap water, but they grew pitting corrosion damage with increasing seawater concentration. STS316L showed better corrosion resistance than STS304.

A Study on the Remaining Concentration of Pesticides in Tap Water of Taejon City by Ellman′s Enzyme Method and the Countermeasure (Ellman 효소법에 의한 대전시 상수도내 살충제의 잔류농도 결정 및 그 대책에 관한 연구)

  • 이봉호;이영순;전종한
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.19-26
    • /
    • 1999
  • The degree of pesticides accumulation in tap water in Taejon from June 1995 to Apr 1996 was measured by Ellman's coupled enzyme assay. Since organic phosphate and carbamate pesticides specifically inhibit the neurotransmitter modulating enzyme acetylcholinesterase(AChE), the enzyme activity can be used as a diagnosis for the pesticides accumulation in water and various samples. During the period of this study, the enzyme activity was changed almost every week. The lowest enzyme activity was 64 % of that of the control reaction and there are several days showing about 100 % enzyme activity. In general, the enzyme activity is higher in summer than other seasons especially early spring times. The pH value of tap water was very close to neutral(pH 7.0) and it seems that the enzyme activity was not affected by the small pH changes. Either boiling of tap water or addition of NaOH solution decomposed the pesticide components. These results show that AChE assay is a convenient, sensitive, and reliable method for detection of pesticides in water samples.

  • PDF

A Study on Design and Fabrication Method of Tap-Offs with Broad-Band Characteristics of for CATV Systems (CATV 시스템용 광대역 특성을 가지는 신호분기기의 설계 및 제작법에 관한 연구)

  • ;;高橋道;石川朝;小峰仁(H. Komine)
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.399-409
    • /
    • 1998
  • In this paper, the broad-band design theory for weakly-coupled Tap-Off for CATV systems has been described and the transmission line impedance matching method has been proposed. The fabricated weakly-coupled Tap-Offs based on the above theory and method have been much improved in the frequency characteristics compared with conventional ones. Thus, the useful bandwidth of weakly-coupled Tap-Offs have been extended from 5 to 2000 MHz. It is also recognized that turn numbers of the coils composing the transformer are not integers but 0.9, 1, 1.9, 2, 2.9, etc., in the actual circuits. Further, the practical measurements of the frequency characteristics for a fabricated weakly-coupled Tap-Off show very good agreements with theoretical results, and hence, the validity of the proposed design theory and transmission line impedance matching method have been confirmed.

  • PDF

Performance Analysis of OFDM/QPSK-DMR System Using One-tap Adaptive Equalizer over Microwave Channel Environments (Microwave 채널 환경에서 단일적응등화기를 이용하는 OFDM/QPSK-DMR 시스템의 성능 분석)

  • 안준배;양희진;조성언;오창헌;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.517-522
    • /
    • 2004
  • In this paper, we have analyzed the performance enhancement of Orthogonal Frequency Division Multiplexing/Quadrature Phase Shift Keying Modulation-Digital Microwave Radio(OFDM/QPSK-DMR) system using Band Limited-Pulse Shaping Filter(BL-PSF) over microwave channel environments. For performance enhancement, the one-tap adaptive equalizer is adopted in the OFDM/QPSK-DMR system and than both BER and signature curve performance are compared with those of single carrier DMR system. Computer simulations confirm that the OFDM/QPSK-DMR system using 16 sub-carrier increase the fade margin about 2 dB over microwave channel environments and that of performance using one-tap adaptive equalizer is highly increased the fade margin as the number of sub-carriers is larger.

A Study on Tap-offs with High Density of Coupling Intervals for CATV and/or MATV Systems (CATV 및 MATV 시스템용 고밀도 결합간격의 신호분기기에 관한 연구)

  • 김동일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.11 no.2
    • /
    • pp.53-59
    • /
    • 1987
  • This paper describes the design theory of a weakly-coupled Tap-off with high density of coupling intervals for CATV and/or MATV systems, by which the degree of freedom in design and density of coupling intervals are significantly increased compared with the intrinsic one. It is also described how to construct the two-way divider (Tap-off) in the generalized type. Furthermore, the practical measurements of the frequency characteristics for a fabricated circuit show very good agreements with theoretical results.

  • PDF