• Title/Summary/Keyword: t-way testing

Search Result 124, Processing Time 0.022 seconds

The effect of different fiber reinforcements on flexural strength of provisional restorative resins: an in-vitro study

  • Kamble, Vaibhav Deorao;Parkhedkar, Rambhau D.;Mowade, Tushar Krishnarao
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • PURPOSE. The aim of this study was to compare the flexural strength of polymethyl methacrylate (PMMA) and bis-acryl composite resin reinforced with polyethylene and glass fibers. MATERIALS AND METHODS. Three groups of rectangular test specimens (n = 15) of each of the two resin/fiber reinforcement were prepared for flexural strength test and unreinforced group served as the control. Specimens were loaded in a universal testing machine until fracture. The mean flexural strengths (MPa) was compared by one way ANOVA test, followed by Scheffe analysis, using a significance level of 0.05. Flexural strength between fiber-reinforced resin groups were compared by independent samples t-test. RESULTS. For control groups, the flexural strength for PMMA (215.53 MPa) was significantly lower than for bis-acryl composite resin (240.09 MPa). Glass fiber reinforcement produced significantly higher flexural strength for both PMMA (267.01 MPa) and bis-acryl composite resin (305.65 MPa), but the polyethylene fibers showed no significant difference (PMMA resin-218.55 MPa and bis-acryl composite resin-241.66 MPa). Among the reinforced groups, silane impregnated glass fibers showed highest flexural strength for bis-acryl composite resin (305.65 MPa). CONCLUSION. Of two fiber reinforcement methods evaluated, glass fiber reinforcement for the PMMA resin and bis-acryl composite resin materials produced highest flexural strength. Clinical implications. On the basis of this in-vitro study, the use of glass and polyethylene fibers may be an effective way to reinforce provisional restorative resins. When esthetics and space are of concern, glass fiber seems to be the most appropriate method for reinforcing provisional restorative resins.

The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut

  • Guleryuz, Aysegul;Korkmaz, Cumhur;Sener, Ayse;Tas, Mehmet Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.304-315
    • /
    • 2021
  • PURPOSE. Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS. PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS. The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P* = .016, P* = .042, P < .001, respectively). CONCLUSION. Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.

Physicochemical properties, cytotoxicity and penetration into dentinal tubules of sodium hypochlorite with and without surfactants

  • Hernan Coaguila-Llerena;Isadora Barbieri ;Mario Tanomaru-Filho ;Renato de Toledo Leonardo;Ana Paula Ramos ;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.47.1-47.11
    • /
    • 2020
  • Objectives: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCidTM Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCidTM (3% NaOCl without surfactant). Materials and Methods: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). Results: ChlorCidTM Surf and ChlorCidTM FAC values were close to those indicated by the manufacturer. ChlorCidTM Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCidTM (p < 0.05). The penetration of ChlorCidTM Surf was higher in cervical and middle segments, compared with ChlorCidTM (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). Conclusions: ChlorCidTM Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCidTM. However, both solutions showed similar cytotoxicity and FAC content.

Effects of Energy System Contribution on Isokinetic Muscle Strength in Various Sport Events Athletes (무산소, 유산소 운동종목별 엘리트선수의 등속성 근기능에 미치는 영향)

  • Kwon, Hyeong-Tae;Kim, Ki-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.272-279
    • /
    • 2018
  • This study was conducted to compare the muscle strength, muscle power, and H/Q ratio according to energy system contribution in athletes participating in various sports. Subjects of the study were assigned into an Anaerobic Exercise Group (AEG, n=60; Short-Distance, Weight Lifting, Jumping, Throwing, Bowling, Golf) and an Endurance Exercise Group (EEG, n=60; Modern Pentathlon, Field Hockey, Handball, Cycle, Boxing, Rowing) groups. Isokinetic peak torque/body weight% and flexor/extensor ratio at 60, 180 deg/sec of knee extension and flexion were measured using an cybex 770. Data analysis was conducted using an independent t-test and one-way ANOVA. Based on the results of this study, there was higher extension, flexion strength and flexion power in the AEG than the EEG (p<0.05). We also confirmed higher muscle strength and muscle power in short distance and jumping athletes than other athletes participating in other events (p<0.05). However, there was no significant difference within the endurance exercise group. The HS ratio was within a stable range of 50% to 60% in all events. Collectively, the outcomes of this study indicate that routine physiological and performance testing can provide measurable benefits for elite athletes and their coaches.

The Effect of Golf Exercise through Rehabilitation Training for Middle-aged Women (중년여성의 재활트레이닝을 통한 골프운동의 효과)

  • Lee, Seung-Do
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.223-235
    • /
    • 2020
  • The purpose of this study is to verify the effect of golf exercise through rehabilitation training for middle-aged women and to suggest the right golf activities. To achieve the purpose of this study, the subjects were 40-50 year old middle-aged women in Jinju, Gyeongnam Province in February 2020. The subjects of this study were 8 women who were controlled by the subjects who needed to be corrected in golf swing orbit. For the accurate measurement test, the program was conducted for 10 days after explaining the purpose and utilization plan of the study. The data collected by testing level of physical strength and distance before and after the experiment were finally analyzed and used. The statistical processing of the collected data was conducted using SPSS win18.0 program, and the statistical techniques were calculated by means of frequency analysis, average(M) and standard deviation(sd), and t-test, one-way ANOVA and multiple regression analysis were conducted. The results of this study through these methods and procedures are as follows. First, rehabilitation training of general characteristics showed a high difference in golf exercise. Second, there was a high difference in the level of rehabilitation training and physical fitness in swing orbit and distance. Third, rehabilitation training and physical fitness level had a high effect on swing orbit and distance.

Development of Mobile Application based on ICF(International Classification of Functioning, Disability and Health) for Provision of Assistive Devices for People with Disabilities (ICF를 활용한 효과적인 장애인 재활보조기기 신청 모바일 어플리케이션 개발)

  • Jung, Bong-Keun;Lee, Sung-A;Min, Se-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.377-385
    • /
    • 2014
  • This study is aimed to introduce the newly developed mobile application for effective provision of assistive devices for people with disabilities in South Korea. By combining of ICF code and ISO 9999 code, more effective way of searching user fit assistive device information and selecting appropriate assistive devices were possible. 10 people with visual impairment were recruited for an usability testing. For the data analysis, paired t-test were used and confidence interval was 95%. The result showed newly developed mobile application was more effective in comparison with on-line based assistive device information. The outcome of this study will enhance the provision of assistive devices for people with disabilities more effectively within better user understanding of their needs and compensate for their body function as well as environmental barriers.

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.

Laboratory and Full-scale Testing to Investigate the Performance of Rock Fall Protection System with Hexagonal Wire Net (육각 낙석방지망의 성능평가를 위한 실내 및 실대형실험)

  • Youn, Ilro;Oh, Sewook;Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.69-75
    • /
    • 2014
  • Rock fall protection system installed against rock slope is one of the most conventional way to protect nearby infra structures. Despite of wide application of typical rectangular nets, virtually installed to protect rock slope face, several problems have also been pointed out up to date. Rectangular draped nets are vulnerable to a sudden external shock such as rock fall, because it doesn't have any systematical buffers or shock absorbers. Furthermore, it has been widely recognized from the some cases of rock fall accident in Korea that rock fall protection nets cause wide range of failure in the rock slope faces due to insufficient pullout bearing capacity of fixing parts. Therefore, in this study, we tried to make a consideration about the problems of existing standard rock fall protection nets in Korea, and develop a new type of hexagonal net with a shock absorber based on design rock fall energy. In this paper, laboratory and full scale test procedure is described to analysis the performance of newly developed hexagonal rock fall net, and the key results are presented and discussed.

DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION (박스 형태의 복합레진 수복시 충전법 및 와동벽에 따른 결합력 차이에 관한 연구)

  • Ko, Eun-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.350-355
    • /
    • 2009
  • Bond strength depends on characteristics of bonding surface and restorative technique. The majority of studies dealing with dentin bond strength were carried out on flat bonding surface, therefore, difference of bond strength between axial wall and pulpal wall is not clear yet. This study evaluated bonding difference between cavity walls in class I composite resin restoration with different filling techniques. Twenty extracted caries-free human third molars were used. Cavities were prepared in 6 ${\times}$4 ${\times}$3 mm box-type and divided into four groups according to filling technique and bonding surface: Group I; bulk filling - pulpal wall, Group II; bulk filling - axial wall, Group III; incremental filling - pulpal wall, Group IV; incremental filling - axial wall. Cavities were filled with Filtek $Z250^{(R)}$(3M/ESPE., USA) and Clearfill SE $bond^{(R)}$(Kuraray, Japan). After 24 hour-storage in $37^{\circ}C$water, the resin bonded teeth were sectioned bucco-lingualy at the center of cavity. Specimens were vertically sectioned into 1.0 ${\times}$1.0 mm thick serial sticks perpendicular to the bond surface using a low-speed diamond saw (Accutom 50, Struers, Copenhagen, Denmark) under water cooling. The trimmed specimens were then attached to the testing device and in turn, was placed in a universal testing machine (EZ test, Shimadzu Co., Kyoto, Japan) for micro-tensile testing at a cross-head speed of 1 mm/min. The results obtained were statistically analyzed using 2-way ANOVA and t-test at a significance level of 95%. The results were as follows: 1. There was no significant difference between bulk filling and incremental filling. 2. There was no significant difference between pulpal wall and axial wall, either. Within the limit of this study, it was concluded that microtensile bond strength was not affected by the filling technique and the site of cavity walls.

Effects of abutment angulation and type of connection on the fracture strength of zirconia abutments (지대주 각도와 연결방식이 지르코니아 지대주의 파절강도에 미치는 영향)

  • Kim, Ho-Seong;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the fracture strength of straight and angled zirconia abutments for internal hex and external hex implants. Materials and methods: Twenty internal hex implants and 20 external hex implants were prepared. The prefabricated straight zirconia abutments and 17-degree-angled zirconia abutments were connected to those 40 implants. The specimens were classified into 4 groups depending on the connection type and abutment angulation; internal hex implant/straight abutment, group INS; internal hex implant/angled abutment, group INA; external hex implant/straight abutment, group EXS; external hex implant/angled abutment, group EXA. All specimens were loaded at a 30-degree angle with a crosshead speed of 1 mm/min using universal testing machine. The fracture loads were analyzed using 2-way ANOVA and independent t-test (${\alpha}=.05$). Results: The mean fracture load for INS was 955.91 N, 933.65 N for INA, 1267.20 N for EXS, and 1405.93 N for EXA. External hex implant showed a significantly higher fracture load, as compared to internal hex implant (P < .001). No significant differences in fracture loads were observed between the straight and angled abutment in internal hex implants (P = .747) and external hex implants (P = .222). Internal hexes of abutments were fractured horizontally in internal connection implants, while lingual cervical neck portions were fractured in external connection implants. Conclusion: The zirconia abutments with external hex implants showed significantly higher fracture strength than those with internal hex implants. However there was no difference in fracture strength between the straight and 17-degree-angled zirconia abutment connected to both implant systems.