• 제목/요약/키워드: systemic circulation

검색결과 134건 처리시간 0.023초

3부위 최적맥파의 주파(h1) 비율 분석을 통한 전체 체순환 평가방법 (Body Systemic Circulation Assessment Method through Analysing the Radial, Dorsalis Pedis, Temporal Arterial Pulse Wave)

  • 유승연;박은성;최예빈;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제33권3호
    • /
    • pp.121-130
    • /
    • 2016
  • Objectives : Recently, people who have normal brachial blood pressure(BP) are being threatened by high-risk disease such as stroke. The aim of this study is to suggest that new method to assess systemic circulation. It can be performed by analyzing optimal blood pulse wave on 3 sites belonging to subjects that have normal BP. Methods : We respectively extracted main peaks(h1) of optimal blood pulse wave on left/right temporal artery(LR1=h1), radial artery(LR2=h1) and dorsalis pedis artery(LR3=h1). We obtained h1 from 30 subjects who are discreetly chosen and have normal BP. Main peak(h1) can be extracted by using 3D pulse imaging analyser(DMP-1000+, DAEYOMEDI Co., Korea) that has 5-level pressure method. We analyzed the ratio of [LR1/LR2] and [LR3/LR2]. Results : In the case of male group, the results are [LR1/LR2=0.7100.177] and [LR3/LR2=0.9290.317]. In the case of female group, the results are [LR1/LR2=0.6680.121] and [LR3/LR2=0.7050.195]. Especially, it is statistically verified that the result of ratio [LR3/LR2] is much higher in male group than in female group(p<0.05). Conclusions : We suggested the standard ratio of [LR1/LR2] and [LR3/LR2] for normal subjects, respectively. It can be adopted as a new method to evaluate the systemic circulation.

LUMPED PARAMETER MODELS OF CARDIOVASCULAR CIRCULATION IN NORMAL AND ARRHYTHMIA CASES

  • Jung, Eun-Ok;Lee, Wan-Ho
    • 대한수학회지
    • /
    • 제43권4호
    • /
    • pp.885-897
    • /
    • 2006
  • A new mathematical model of pumping heart coupled to lumped compartments of blood circulation is presented. This lumped pulsatile cardiovascular model consists of eight compartments of the body that include pumping heart, the systemic circulation, and the pulmonary circulation. The governing equations for the pressure and volume in each vascular compartment are derived from the following equations: Ohm's law, conservation of volume, and the definition of compliances. The pumping heart is modeled by the time-dependent linear curves of compliances in the heart. We show that the numerical results in normal case are in agreement with corresponding data found in the literature. We extend the developed lumped model of circulation in normal case into a specific model for arrhythmia. These models provide valuable tools in examining and understanding cardiovascular diseases.

Current advances in adenovirus nanocomplexes: more specificity and less immunogenicity

  • Kang, Eun-Ah;Yun, Chae-Ok
    • BMB Reports
    • /
    • 제43권12호
    • /
    • pp.781-788
    • /
    • 2010
  • An often overlooked issue in the field of adenovirus (Ad)-mediated cancer gene therapy is its limited capacity for effective systemic delivery. Although primary tumors can be treated effectively with intralesional injection of conventional Ad vectors, systemic metastasis is difficult to cure. Systemic administration of conventional naked Ads leads to acute accumulation of Ad particles in the liver, induction of neutralizing antibody, short blood circulation half-life, non-specific biodistribution in undesired organs, and low selective accumulation in the target disease site. Versatile strategies involving the modification of viral surfaces with polymers and nanomaterials have been designed for the purpose of maximizing Ad anti-tumor activity and specificity by systemic administration. Integration of viral and non-viral nanomaterials will substantially advance both fields, creating new concepts in gene therapeutics. This review focuses on current advances in the development of smart Ad hybrid nanocomplexes based on various design-based strategies for optimal Ad systemic administration.

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제2권2호
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

Integrated Bioinformatics Approach Reveals Crosstalk Between Tumor Stroma and Peripheral Blood Mononuclear Cells in Breast Cancer

  • He, Lang;Wang, Dan;Wei, Na;Guo, Zheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.1003-1008
    • /
    • 2016
  • Breast cancer is now the leading cause of cancer death in women worldwide. Cancer progression is driven not only by cancer cell intrinsic alterations and interactions with tumor microenvironment, but also by systemic effects. Integration of multiple profiling data may provide insights into the underlying molecular mechanisms of complex systemic processes. We performed a bioinformatic analysis of two public available microarray datasets for breast tumor stroma and peripheral blood mononuclear cells, featuring integrated transcriptomics data, protein-protein interactions (PPIs) and protein subcellular localization, to identify genes and biological pathways that contribute to dialogue between tumor stroma and the peripheral circulation. Genes of the integrin family as well as CXCR4 proved to be hub nodes of the crosstalk network and may play an important role in response to stroma-derived chemoattractants. This study pointed to potential for development of therapeutic strategies that target systemic signals travelling through the circulation and interdict tumor cell recruitment.

외상에 의해 발생한 체동맥-폐혈관루 - 1예 보고 - (Traumatic Systemic Artery to Pulmonary Vessel Fistula - A case report -)

  • 김건우;김정호;최수진;박국양;박철현;이재익
    • Journal of Chest Surgery
    • /
    • 제40권1호
    • /
    • pp.74-78
    • /
    • 2007
  • 체동맥-폐혈관루(systemic artery to pulmonary vessel fistula, SAPVF)는 비정상적으로 형성된 체동맥과 폐혈관 사이의 연결이다. 이는 대부분 선천적으로 발생하지만, 드물게는 폐나 흉막의 종양, 염증성 질환 및 외상 등으로 인해 발생할 수 있다. 내원 16년 전 교통사고로 인한 횡경막 파열로 수술한 과거력이 있는 38세 남자 환자가 객혈을 주소로 내원하였고, 흉부 컴퓨터 단층 촬영과 혈관 조영술로 늑간동맥 및 내흉 동맥과 폐혈관이 연결된 SAPVF를 진단하였다. 저자들은 외상에 의한 SAPVF 1예를 경험하였고, 혈관 색전술을 시행하여 좋은 결과를 얻었기에 국내 문헌상으로는 최초로 이를 보고하는 바이다.

인체 심혈관계의 이론적 분석을 위한 시스템 시뮬레이션모델에 관한 연구 (Systemic Simulation Models for the Theoretical Analysis of Human Cardiovascular System)

  • 고형종;윤찬현;심은보
    • 제어로봇시스템학회논문지
    • /
    • 제10권12호
    • /
    • pp.1181-1188
    • /
    • 2004
  • This paper reviews the main aspects of cardiovascular system dynamics with emphasis on modeling hemodynamic characteristics using a lumped parameter approach. Methodological and physiological aspects of the circulation dynamics are summarized with the help of existing mathematical models: The main characteristics of the hemodynamic elements, such as the heart and arterial and venous systems, are first described. Lumped models of micro-circulation and pulmonary circulation are introduced. We also discuss the feedback control of cardiovascular system. The control pathways that participate in feedback mechanisms (baroreceptors and cardiopulmonary receptors) are described to explain the interaction between hemodynamics and autonomic nerve control in the circulation. Based on a set-point model, the computational aspects of reflex control are explained. In final chapter we present the present research trend in this field and discuss the future studies of cardiovascular system modeling.

A Novel Approach to the Discovery of Non-systemic Anti-inflammatory Steroids; Antedrug

  • Lee, Henry-J.;Ko, Dong-Hoon
    • Archives of Pharmacal Research
    • /
    • 제22권3호
    • /
    • pp.279-287
    • /
    • 1999
  • Therapeutic use of anti-inflammatory steroids is limited due primarily to their systemic suppressive effects on pituitary function and the immune system.. To overcome the clinical limitation, a new approach toward the discovery of non-systemic anti-inflammatory steroids is based upon the antedrug concept introduced by this laboratory. The new concept describes locally active agents which are designed to undergo a predictable biotransformation to inactive metabolites upon entry into systemic circulation from the applied site. Thus, true antedrugs are devoid of systemic adverse effects. In a continuing effort, 16$\alpha$-carboxylate and isoxazoline derivatives of prednisolone have been synthesized and screened. In the croton oil-induced ear edema bioassay, the following relative potencies were obtained setting hydrocortisone=1.0; 3a, 1.5; 3b, 3.1; 4a, 4.0; 4b, 12.2; 5b, 8.2; 6b, 11.2; 7a, 1.9; 7b, 4.1; 8a, 3.3; 8b 6.8; 9a, 0.7; 9b 8.6; 10a 2.6; 10b, 7.4. Results of the five-day bioassay indicated that, in contrast to the parent compound, the novel steroidal antedrugs did not significantly alter body weight gain, thymus weights, adrenal weights or plasma corticosterone levels. Taken together, the antedrug concept appears to be a fundamentally sound strategy for the separation of local anti-inflammatory activity form systemic adverse effects.

  • PDF

한국산 잡견에서 백혈구 제거 충진액이 체외순환 중 위점막 이산화탄소 농도와 IL-8 수준에 미치는 영향 (The Effects of Leukocyte Depleted Priming Solution on the Gastric Mucosal $Co_{2}$ Partial Pressure and Serum IL-8 Level during Cardiopulmonary Bypass in Korean Mongrel Dogs)

  • 박건;이종호;김진호;진웅;권종범;김치경;왕영필
    • Journal of Chest Surgery
    • /
    • 제38권12호
    • /
    • pp.807-814
    • /
    • 2005
  • 배경: 체외순환은 심정지를 필요로 하는 모든 심장 수술에서 정지된 심장의 기능을 대신하여 환자의 말초 장기의 혈액순환을 유지하기 위한 필수적인 과정이다. 그러나 체외순환은 필연적으로 인공도관을 관류하는 특성상 신체의 혈관계를 흐르는 혈류와 달리 혈액손상에 따른 전신성 염증반응을 피할 수 없으며, 이러한 전신성 염증반응과 함께 말초혈관의 미세혈관 순환장애가 체외순환동안에 원발장기의 손상을 초래하는 것으로 생각된다. 저자들은 전신성 염증반응을 일으키는 주된 혈액성분인 백혈구를 제거한 충진액을 사용하여 전신성 염증반응을 줄일 수 있는가를 확인하고, 체외순환도중 위점막의 산도를 측정함으로써 위점막의 미세혈류에 대한 백혈구 제거 충진액의 효과를 확인하기 위하여 실험을 진행하였다. 대상 및 방법: 실험군은 15마리의 한국산 잡견을 충진액의 성분에 따라 비혈액성 충진액군, 백혈구 제거 혈액성 충진액군, 백혈구 비제거 혈액성 충진액군으로 각각 5마리씩 세 군으로 나누었다. 세 군 모두에서 2시간의 체외순환 및 연속된 4시간의 마취유지를 시행하였으며, 체외순환 전과 체외순환 후 1시간, 2시간, 체외순환 종료 후 2시간 4시간에 위점막 이산화탄소 농도와 산도, 동맥혈 이산화탄소 분압 과 호기말 이산화탄소 분압을 측정하고, 염증반응의 지표검사를 위하여 동맥혈을 채혈하였다. 전신성 염증반응의 정도는 채취한 동맥혈에서 ELISA (enzyme linked immunosorbent assay)법을 이용하여 IL-8의 수준을 검사하였다. 결과: 1, 위점막의 이산화탄소 농도는 백혈구 제거 혈액성 충진액군이 백혈구 비제거 혈액성 충진액군과 비혈액성 충진액군에 비하여 유의하게 낮았다(p=0.02, 0.01). 2. 위점막의 산도는 백혈구 제거 혈액성 충진액군과 백혈구 비제거 혈액성 충진액군간에 유의한 차이를 보였다(p=0.01). 3. 전신성 염증반응의 정도를 확인하기 위하여 측정한 IL-8의 수준은 백혈구 제거 혈액성 충진액군과 비혈액성 충진액군이 백혈구 비제거 혈액성 충진액군에 비하여 유의하게 낮았다(p=0.01, 0.01). 결론: 백혈구를 제거한 혈액성 충진액을 사용하는 것이 체외순환중 위점막의 미세순환 장애를 방지하고 전신성 염증반응을 감소시킬 수 있음을 확인하였다.

Humidifier disinfectants, unfinished stories

  • Choi, Yeyong;Paek, Domyung
    • Environmental Analysis Health and Toxicology
    • /
    • 제31권
    • /
    • pp.4.1-4.2
    • /
    • 2016
  • Once released into the air, humidifier disinfectants became tiny nano-size particles, and resulted in chemical bronchoalveolitis. Families had lost their most beloved members, and even some of them became broken. Based on an estimate of two million potential victims who had experienced adverse effects from the use of humidifier disinfectants, we can say that what we have observed was only the tip of the iceberg. Problems of entire airways, as well as other systemic effects, should be examined, as we know these nano-size particles can irritate cell membranes and migrate into systemic circulation. The story of humidifier disinfectant is not finished yet.