• 제목/요약/키워드: system response

검색결과 13,106건 처리시간 0.04초

Methodology of seismic-response-correlation-coefficient calculation for seismic probabilistic safety assessment of multi-unit nuclear power plants

  • Eem, Seunghyun;Choi, In-Kil;Yang, Beomjoo;Kwag, Shinyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.967-973
    • /
    • 2021
  • In 2011, an earthquake and subsequent tsunami hit the Fukushima Daiichi Nuclear Power Plant, causing simultaneous accidents in several reactors. This accident shows us that if there are several reactors on site, the seismic risk to multiple units is important to consider, in addition to that to single units in isolation. When a seismic event occurs, a seismic-failure correlation exists between the nuclear power plant's structures, systems, and components (SSCs) due to their seismic-response and seismic-capacity correlations. Therefore, it is necessary to evaluate the multi-unit seismic risk by considering the SSCs' seismic-failure-correlation effect. In this study, a methodology is proposed to obtain the seismic-response-correlation coefficient between SSCs to calculate the risk to multi-unit facilities. This coefficient is calculated from a probabilistic multi-unit seismic-response analysis. The seismic-response and seismic-failure-correlation coefficients of the emergency diesel generators installed within the units are successfully derived via the proposed method. In addition, the distribution of the seismic-response-correlation coefficient was observed as a function of the distance between SSCs of various dynamic characteristics. It is demonstrated that the proposed methodology can reasonably derive the seismic-response-correlation coefficient between SSCs, which is the input data for multi-unit seismic probabilistic safety assessment.

Tuned mass dampers for torsionally coupled systems

  • Pansare, A.P.;Jangid, R.S.
    • Wind and Structures
    • /
    • 제6권1호
    • /
    • pp.23-40
    • /
    • 2003
  • The steady state response of a torsionally coupled system with tuned mass dampers (TMDs) to external wind-induced harmonic excitation is presented. The torsionally coupled system is considered as one-way eccentric system. The eccentricity considered in the system is accidental eccentricity only. The performance of single tuned mass damper (TMD) optimally designed without considering the torsion is investigated for the torsionally coupled system and found that the effectiveness of a single TMD is significantly reduced due to torsion in the system. However, the design of TMD system without considering the torsion is only justified for torsionally stiff systems. Further, the optimum parameters of a single TMD considering the accidental eccentricity are obtained using numerical searching technique for different values of uncoupled torsional to lateral frequency ratio and aspect ratio of the system. The optimally designed single TMD system is found to be less effective for torsionally coupled system in comparison to uncoupled system. This is due to the fact that a torsionally coupled system has two natural frequencies of vibration, as a result, at least two TMDs are required which can control both lateral and torsional response of the system. The optimum damper parameters of different alternate arrangements such as (i) two identical TMDs placed at opposite corners, (ii) two independent TMDs and (iii) four TMDs are evaluated for minimum response of the system. The comparative performance of the above TMDs arrangements is also studied for both torsionally coupled and uncoupled systems. It is found that four TMDs arrangement is quite effective solution for vibration control of torsionally coupled system.

선체구조의 탄성지지 효과를 고려한 LNG 운반선 방열구조의 슬로싱 충격응답 해석법에 관한 연구 (Sloshing Impact Response Analysis for Insulation System of LNG CCS Considering Elastic Support Effects of Hull Structures)

  • 노인식;기민석;김성찬;이장현;김용환
    • 한국해양공학회지
    • /
    • 제31권5호
    • /
    • pp.357-363
    • /
    • 2017
  • The sloshing pressure acting on a membrane-type LNG CCS is a typical irregular impact load, and the structural response of a tank system induced by sloshing also shows very complex behavior, including fluid structure interaction. Therefore, it is not easy to accurately estimate the sloshing impact pressures and resulting structural response. Moreover, a huge time consuming process to deal with the enormous pressure data obtained during a model tank test and the following structural analysis would be inevitable. To reduce the computation time for structural analysis, in this study, a rational structural modeling strategy was considered, and a simplified scheme to analyze the dynamic structural responses of an LNG CCS was introduced, which was based on the concept of the linear combination of the triangular response functions obtained by a transient response analysis of structures under unit triangular impact pressure. A structural analysis of a real Mark III membrane type insulation system under the sloshing impact pressure time histories obtained by model tests was performed using the various proposed structural models and simplified analysis scheme. The results were investigated in detail, including the elastic support effects of the hull structure.

이중골조시스템으로 설계된 복강판-모듈러 구조물의 반응수정계수에 관한 연구 (Study on the Response Modification Factor for a Lightweight Steel Panel-Modular Structure Designed as a Dual Frame System)

  • 이어진;홍성걸
    • 한국지진공학회논문집
    • /
    • 제15권1호
    • /
    • pp.39-48
    • /
    • 2011
  • 본 연구에서는 복강판-모듈러 시스템과 같이 구조 기준에 명시되지 않은 새로운 시스템의 반응수정계수를 산정하는 절차를 제안하였다. 기본 개념은 구조성능 실험결과를 바탕으로 모델링 된 시스템의 비선형 정적 해석 곡선으로부터 세부 구성요소인 초과강도계수와 연성계수의 도출하고, 단자유도 시스템으로 간주하고 평가된 반응수정계수를 다자유도 동적 거동을 고려한 다자유도 밑면전단 수정계수로 수정하여 시스템의 최종적인 반응수정계수를 결정하는 것이다. 제안한 절차에 따라 이중골조시스템으로 설계된 2층부터 5층까지의 복강판-모듈러 시스템에 대해 평가한 결과, 최종적인 반응수정계수는 5층(층고 4m기준)을 복강판-모듈러 시스템의 적용 가능한 층수의 상한으로 하여 4로 결정하는 것이 타당할 것으로 판단하였다.

국내 지진동 특성에 대한 기기 용접 정착부의 비탄성에너지 흡수계수를 고려한 지진취약도 평가 (Seismic Fragility Analysis of Equipment Considering the Inelastic Energy Absorption Factor of Weld Anchorage for Seismic Characteristics in Korea)

  • 임승현;김건규;최인길;곽신영
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.69-75
    • /
    • 2023
  • In Korea, most nuclear power plants were designed based on the design response spectrum of Regulatory Guide 1.60 of the NRC. However, in the case of earthquakes occurring in the country, the characteristics of seismic motions in Korea and the design response spectrum differed. The seismic motion in Korea had a higher spectral acceleration in the high-frequency range compared to the design response spectrum. The seismic capacity may be reduced when evaluating the seismic performance of the equipment with high-frequency earthquakes compared with what is evaluated by the design response spectrum for the equipment with a high natural frequency. Therefore, EPRI proposed the inelastic energy absorption factor for the equipment anchorage. In this study, the seismic performance of welding anchorage was evaluated by considering domestic seismic characteristics and EPRI's inelastic energy absorption factor. In order to reflect the characteristics of domestic earthquakes, the uniform hazard response spectrum (UHRS) of Uljin was used. Moreover, the seismic performance of the equipment was evaluated with a design response spectrum of R.G.1.60 and a uniform hazard response spectrum (UHRS) as seismic inputs. As a result, it was confirmed that the seismic performance of the weld anchorage could be increased when the inelastic energy absorption factor is used. Also, a comparative analysis was performed on the seismic capacity of the anchorage of equipment by the welding and the extended bolt.

Analysis of System Performance Degradation Using Sinusoidally Modulated Signal in Optical Fiber Communication Systems

  • Lee, Jong-Hyung;Han, Dae-Hyun;Park, Byeong-Yoon
    • Journal of the Optical Society of Korea
    • /
    • 제8권2호
    • /
    • pp.59-64
    • /
    • 2004
  • The response of a single-mode fiber to a sinusoidally modulated input has been studied to see its utility in measuring system performance in the presence of fiber nonlinearities. The sinusoidally modulated signal models an alternating bit sequence of ones and zeros in on-off keying. The sinusoidal response of normally dispersive fiber shows a strong correlation with eye-opening penalty (EOP) over a wide range of the nonlinearity parameter N (0.1 < N$^2$< 100). This result implies that the measurement of the sinusoidal response can be an alternate way of measuring EOP without having a long sequence of randomly modulated input bits. But in the anomalous dispersion region, the sinusoidal response has a much more limited range of application to estimate system performance.

초음파 센서를 이용한 담적(痰積)진단시스템의 설계와 응답특성 (The Development and Response Characteristic Analysis of Dam Jerk Diagnosis System Using Ultrasonic Sensor)

  • 이용흠;신태민;이균정
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권4호
    • /
    • pp.189-194
    • /
    • 2006
  • Dam jerk causes a chronic stomach disorder. The number of the patient of the Dam jerk increase in these days. However, there are no objective and quantitative study for a diagnosis of Dam jerk. Therefore, we designed diagnosis system using ultrasonic response signal for a diagnosis of Dam jerk. It was used to collect the response signal that is reflected at Dam jerk region of the abdominal. And then, the response signal at the Dam jerk region is 20% higher than the normal region. In the result. we could prove the reliability of the system.

특성행렬 직접 규명법에 의한 강체특성의 실험적 추정 (Experimental Identification of Rigid Body Properties by Direct System Identification Method)

  • Jeong, W.B.;Ryu, S.J.;Koe, D.M.
    • 한국정밀공학회지
    • /
    • 제12권9호
    • /
    • pp.22-29
    • /
    • 1995
  • An experimental method to identify the rigid properties (mass, moment of inertia, center of mass) of mounted structures is presented. A direct system identification method is developed and applied to identify the mass, damping and stiffness martix directly from the translational response of vibration testing. Conventional method is sensitive to noise since it needs artificial rotational response of temporary center of mass which is made by the linear transformation of translational response. A presented method needs only the translational response, and it is robuster to noise than conventional method. Several experimental and numerical implementations show the presented method is effective.

  • PDF

반응표면법을 이용한 초음파 임프린팅 공정의 최적화 (Optimization of Ultrasonic Imprinting Using the Response Surface Method)

  • 정우신;조영학;박근
    • 소성∙가공
    • /
    • 제22권1호
    • /
    • pp.36-41
    • /
    • 2013
  • The present study examines the micro-pattern replication on a plastic film using ultrasonic imprinting. Ultrasonic imprinting uses ultrasonic waves to generate repetitive microscale deformation in the polymer film. The resulting deformation heat on the surface of the film causes the surface region to soften sufficiently so that a replication of the micro-pattern can be obtained. To successfully replicate the micro-pattern on a large area of polymer film, a high replication ratio is needed as well as good uniformity over the entire region. In this study, a horn design is investigated by finite element analysis and is optimized through a response surface analysis. In the ultrasonic imprinting experiments, the response surface method was also used to determine the optimal processing conditions for better replication characteristics.

조속기 응동 조류계산 기반 장기 전압안정도 모의 (Governor-Response Power Flow Based Long-term Voltage Stability Simulation)

  • 송화창;김영곤;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.160-162
    • /
    • 2008
  • This paper present a practical method for long-term voltage stability simulation based on a governor-response power flow. Governor-response power flow (GPF) is to model the long-term system response in the interval from 3 to 30 seconds after disturbance. In this paper, it is assumed that the GPF model ran capture the system state before load restoration starts in contingent conditions. This paper discusses the applicability of GPF to long-term simulation for voltage stability analysis and then explains the GPF formulation and the procedure of the proposed simulation. In addition the paper includes the simulation results with the modified New England 39-bus system.

  • PDF