• Title/Summary/Keyword: synchrotron x-rays

Search Result 23, Processing Time 0.029 seconds

GPS QUASARS AS SPECIAL BLAZARS

  • BAI J. M.;LEE MYUNG GYONG
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.125-128
    • /
    • 2005
  • In this paper, we argue that the gigahertz peaked spectrum (GPS) quasars are special blazars, blazars in dense and dusty gas enviornment. The ROSAT detection rate of GPS quasars is similar to that of flat spectrum radio quasars (FSRQs), suggesting that the relativistic jets in GPS quasars are oriented at small angle to the line of sight. Due to strong inverse Compton scattering off infrared photons from dense and dusty nuclear interstellar media in GPS quasars, most of them may have significant soft gamma-ray and X-ray emission, which is consistent with ASCA X-ray observations. Because Compton cooling in GPS quasars is stronger than that in FSRQs, synchrotron emission in GPS quasars may less dominate over thermal emission of the accretion disk and hot dust, hence most GPS quasars show low optical polarization and small variability, consistent with observations. We suggest that it is the significant radio emission of electron/positron pairs produced by the interaction of gamma-rays with the dense gas and dust grains in GPS quasars that makes GPS quasars show steep radio spectra, low radio polarization, and relatively faint VLBI/VLBA cores. Whether GPS quasars are special blazars can be tested by gamma-ray observations with GLAST in the near future, with the detection rate of GPS quasars being similar to that of FSRQs.

X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube (X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구)

  • Lee Sang-Joon;Kim Seok;Paik Bu-Geun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • Lee, Hyeon-Hwi;Kim, Hyo-Jeong;Kim, Jang-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF

CRYSTALLIZAT10N OF $\gamma$-GLUTAMYLCYSTEINE SYNTHETASE FROM Escherichia coli (대장균주로부터 분리한 GSH-1 효소의 결정화)

  • 황광언;김경규
    • Korean Journal of Crystallography
    • /
    • v.4 no.2
    • /
    • pp.100-104
    • /
    • 1993
  • Reduced glutathione (GSH) plays a vital role in the metabolism of all cells. Glutathions, a tripeptide cowfosed of glutamic acid, cysteane, and gtycina is synthesized by two synthesized reutions. The first is catalyzed by Y-glutamylcysteine synthetase (GSH-I) and the second by glutathione synthetase (GSH-ll). The glutathione biosynthetic pathway of E. coziis mainly controlled by nonallosteric feedback inhibition of GHS-I by GSH. Determination of the three-dimensional structure of GSH-I by X-ray crystallography is necessary in order to understand the structure-function relationship at the molecular level. As the (irst step toward its structure determination, crystallization of 5. coli V-glutamylcystfine synthetase (GSH-I) has been achived using the hanging drop vapor diffusion method and capillaw method. Crystals of GSH-I have been grown from ammonium sulfate solution. The crystals grew at room temperature within 10 days to dimensions of 0.2 m x 0.2 m x 0.2 ml by hanging drop vapor diffusion method and diffracted to about 4 A resolution using synchrotron X-rays. Another crystal, grown by the capillary method to dimensions of 0.25 mm x 0.25 mm x 0.3 mm within 40 days, diffracted to about 4 A resolution using X-rays from a rotating anode.

  • PDF

Development of X-ray PIV Technique and its Application to Blood Flow (X-ray PIV 기법의 개발과 혈액 유동에의 적용연구)

  • Kim, Guk Bae;Lee, Sang Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1182-1188
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed to measure quantitative information on flows inside opaque conduits and on opaque-fluid flows. At first, the developed x-ray PIV technique was applied to flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, refraction-based edge enhancement mechanism was employed using detectable tracer particles. The optimal distance between with the sample and detector was experimentally determined. The resulting amassed velocity field data were in reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to blood flow in a microchannel. The flow pattern of blood was visualifed by enhancing the diffraction/interference -bas ed characteristic s of blood cells on synchrotron x-rays without any contrast agent or tracer particles. That is, the flow-pattern image of blood was achieved by optimizing the sample (blood) to detector distance and the sample thickness. Quantitative velocity field information was obtained by applying PIV algorithm to the enhanced x-ray flow images. The measured velocity field data show a typical flow structure of flow in a macro-scale channel.

Crystallization and preliminary X-ray analysis of API5-FGF2 complex

  • Bong, Seoung Min;Lee, Byung Il
    • Biodesign
    • /
    • v.6 no.4
    • /
    • pp.92-95
    • /
    • 2018
  • API5 is a unique oncogenic, non-BIR type IAP nuclear protein and is up-regulated in several cancers. It exerts several functions, such as apoptosis inhibition, cell cycle progression, cancer immune escape, and anticancer drug resistance. Although structural studies of API have revealed that API5 mediates protein-protein interactions, its detailed molecular functions remain unknown. Since FGF2 is one of API5's major interacting proteins, structural studies of the API5-FGF2 complex will provide insight into both proteins' molecular function. We overexpressed and purified API5 and FGF2 in Escherichia coli and crystallized the API-FGF2 complex using polyethylene glycol (PEG) 6000 as a precipitant. Diffraction data were collected to a $2.7{\AA}$ resolution using synchrotron X-rays. Preliminary diffraction analysis revealed that the API5-FGF2 complex crystal belongs to the space group $P2_12_12_1$ with the following unit cell parameters: a = 46.862, b = 76.523, $c=208.161{\AA}$. One asymmetric unit with 49.9% solvent contains one API5-FGF2 complex. Molecular replacement calculation, using API5 and FGF2 coordinates, provided a clear electron density map for an API5-FGF2 complex.

Absorption Spectroscopy of Biological Specimens Near X-ray Absorption Edges of Constituent Elements

  • Ito, Atsushi;Shinohara, Kunio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.460-462
    • /
    • 2002
  • Absorption spectra of biological specimens in the soft X-ray region have been presented with special reference to the XANES (X-ray absorption Near Edge Structure) of constituent elements. Absorption spectrum in this wavelength region is characterized by the absorption edges from which elemental content could be derived. In addition, XANES has a characteristic profile for chemical environment around the element such as chemical bond. Using the specific absorption peak we can assign not only the chemical bond but also molecules having such a chemical bond. In the present paper, absorption spectrum of DNA was measured in the wavelength range from 1.5nm to 5nm. Spectrum of Chinese Hamster Ovary (CHO) cells was compared with the DNA spectrum. XANES were distinct at the K absorption edges of major elements, C, N and O. In the spectrum of the cells prominent peaks at the L absorption edge of minor element Ca were also detectable. XANES profiles in small local areas in a cell could also be measured in combination with X-ray microscopy. These give information about local chemical environment in a cell. XANES at the phosphorus K absorption edge in a human HeLa cell was successfully obtained corresponding to a sharp and intensive XANES peak of DNA.

  • PDF

X-Ray Diffraction line profile analysis of defects and precipitates in high displacement damage neutron-irradiated austenitic stainless steels

  • Shreevalli M.;Ran Vijay Kumar;Divakar R.;Ashish K.;Padmaprabu C.;Karthik V.;Archna Sagdeo
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.114-122
    • /
    • 2024
  • Irradiation-induced defects and the precipitates in the wrapper material of the Indian Fast Breeder Test Reactor (FBTR), SS 316 are analyzed using the synchrotron source-based Angle Dispersive X-Ray Diffraction (ADXRD) technique with X-rays of energy 17.185 keV (wavelength ~0.72146 Å). The differences and similarities in the high displacement damage samples as a function of dpa (displacement per atom) and dpa rate in the range of 2.9 × 10-7- 9 × 10-7 dpa/s are studied. Ferrite and M23C6 are commonly observed in the present set of high displacement damage 40-74 dpa SS 316 samples irradiated at temperatures in the range of 400-483 ℃. Also, the dislocation density has increased as a function of the irradiation dose. The X-ray diffraction peak profile parameters quantified such as peak shift and asymmetry show that the irradiation-induced defects are sensitive to the dpa rate-irradiation temperature combinations. The increase in yield strength as a function of displacement damage is also correlated to the dislocation density.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Real-Time Observation of Temperature-Dependen Strain in Poly (3-hexylthiophene) Crystals in a Mixed Donor and Acceptor Thin Film

  • Lee, Hyeon-Hwi;Kim, Hyo-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.163-163
    • /
    • 2012
  • We observed strain evolution of P3HT crystals in P3HT:PCBM films and the effect of Al electrode on the evolution during real time annealing process. Based on simple assumptions, both relaxed lattice parameters and thermal expansion coefficient could be quantitatively determined. P3HT:PCBM films displayed tensile strain in as-prepared samples regardless of the presence of an Al layer. In the absence of Al layer, P3HT crystals showed only strain relaxation at an annealing temperature of $180^{\circ}C$. Meanwhile In the presence of an Al layer, the strain was relaxed and changed to compressive strain at around 120C annealing temperature, which indicated a tightening of the thiophene ring packing. These behaviors support the improved performance of devices fabricated by post annealing process.

  • PDF