• 제목/요약/키워드: synchronous machine

검색결과 421건 처리시간 0.028초

Sensorless Control of the Synchronous Reluctance Machine

  • Kilthau, A.;Pacas, J.M.
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.95-103
    • /
    • 2002
  • The paper deals with the control of the synchronous reluctance machine without position senser. A method for the computation of the transformation angle out of terminal voltages and currents is presented. The injection of test signals allows operation at zero speed. Fundamental for this control scheme is the angle estimation method over the whole operating range including field-weakening is discussed in detail. The implementation of the angle estimation method in a rotor-oriented control scheme and practical results are demonstrated.

PM Assisted, Brushless Wound Rotor Synchronous Machine

  • Ali, Qasim;Atiq, Shahid;Lipo, Thomas A.;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.399-404
    • /
    • 2016
  • This paper presents a new permanent magnet (PM) assisted topology for a recently introduced brushless wound rotor synchronous machine (BL-WRSM) [1]. The BL-WRSM had a dual-inverter configuration for generating a composite magneto motive force (MMF) with a fundamental component and a subharmonic component. The subharmonic component of the MMF is used for brushless excitation of the rotor. In this paper, additional PMs were introduced on the rotor of the BL-WRSM, making it a hybrid BL-WRSM. We also discussed the flux weakening operation for the hybrid BL-WRSM. The hybrid BL-WRSM offered advantages for starting the machine and provided better performance under full-load conditions. The finite element method (FEM) was used to analyze the performance of the hybrid BL-WRSM, and we compared its performance with BL-WRSM. Finally, prototypes were built with and without the PM-assistance, and experiments were conducted to demonstrate their performance.

30kVA 초전도 전동기의 기기상수 (Machine Constants of 30 kVA Superconducting Synchronous Motor)

  • 최경달;한송엽;츠키지히로시;호시노토모노리;무타이쯔야
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1996
  • For the test of the operating characteristics as a moor, a 20 kVA super conducting synchronous machine with rotating field windings has been made in Saga university, Japan from 1991. Before the load tests of it as a motor, we carried out cooling down tests and measured its machine constants. During the cooling down tests, we found that the rotor itself had no cryogenic problem, but the inlet part for liquid He had one. Though enough liquid He couldn't be accumulated inside the rotor because of this problem, we drove field currents up to 20 A and could acquire the machine constants and V curves of the super-conducting synchronous motor.

  • PDF

Direct Torque Control Strategy (DTC) Based on Fuzzy Logic Controller for a Permanent Magnet Synchronous Machine Drive

  • Tlemcani, A.;Bouchhida, O.;Benmansour, K.;Boudana, D.;Boucherit, M.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.66-78
    • /
    • 2009
  • This paper introduces the design of a fuzzy logic controller in conjunction with direct torque control strategy for a Permanent Magnet synchronous machine. A stator flux angle mapping technique is proposed to reduce significantly the size of the rule base to a great extent so that the fuzzy reasoning speed increases. Also, a fuzzy resistance estimator is developed to estimate the change in the stator resistance. The change in the steady state value of stator current for a constant torque and flux reference is used to change the value of stator resistance used by the controller to match the machine resistance.

Performance Evaluation of an Integrated Starter-Alternator with an IPM Synchronous Machine under Sensor-less Operation

  • Xu, Zhuang;Rahman, M.F.;Wang, G.;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.49-57
    • /
    • 2012
  • This paper presents performance evaluation of an Integrated Starter-Alternator (ISA) prototype with an Interior Permanent Magnet (IPM) synchronous machine under sensor-less operation. To attain a high starting torque at zero speed and in subsequent extremely low speed range, a hybrid signal injection method is proposed. At higher speed, an improved stator flux observer is used for the stator flux estimation. This observer is able to produce accurately-estimated stator flux linkage for high performance Direct Torque and Flux Control (DTFC) implementation. The sensor-less DTFC IPM synchronous machine drive takes full advantage of the capacity of the power converter and fulfills the control specifications for the ISA. The trajectory control algorithm responds rapidly and in a well behaved manner over a wide range of operating conditions. The experimental results verify the feasibility and advantages of the system.

주파수 측정방법에 따른 HVDC시스뎀의 응답특성 (Response Characteristic of HVDC System According to Frequency Sensing Methods)

  • 김찬기;양병모;박종광;정길조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.299-303
    • /
    • 2003
  • This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system areto fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is use a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC Program and experimental test.

  • PDF

정지형 주파수 변환 장치를 활용한 대용량 동기 발전 전동기 운전에 관한 연구 (A study of Large Synchronous Machine Drive using Static Frequency Converter)

  • 박신현;김장목;임익헌;류호선
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.496-503
    • /
    • 2003
  • 대용량 동기 발전 전동기 운전에는 주로 사이리스터를 이용한 정지형 주파수 변환 장치(SFC : Static Frequency Converter)시스템이 널리 사용되고 있다. 많은 문헌들에 의해 SFC시스템 운전 알고리즘이 제시되어 있지만 대부분이 초기 기동 및 정격속도까지의 기동 운전에 관해 언급되어 있으며 실제 가스터빈, 양수발전소등과 같은 산업에 적용되고 있는 계통 연계를 통한 정격 속도 운전 및 정지시의 회생 제동에 관한 기술적 언급은 자세히 설명되어 있지 않다 본 논문은 SFC를 활용한 동기 발전 전동기 운전의 전 영역 운전에 관한 알고리즘을 제시하였다. 실제 산업 현장에 적용되고 있는 기동 제어 영역, 계통 연계에 의한 정속도 운전 영역 그리고 회생 제동 제어 영역 각각의 알고리즘을 제시하였으며 실효성 및 타당성을 실험을 통하여 검증하였다.

약한 AC 계통에서 동기조상기용 여자 시스템 특성에 따른 HVDC 과도 특성 (Dynamic Performance of HVDC According to Excitation System Characteristics of Synchronous Compensator in a Weak AC System)

  • 김찬기;김정부;심응보
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.431-440
    • /
    • 2000
  • This paper analyses the dynamic performance of HVDC System connected to a weak AC system for various exciter characteristics of synchronous machines connected at the converter bus. Conventionally capacitors are used to supply reactive power requirement at a strong converter bus. But the installation of synchronous machine is essential in a isolated weak network to re-start after a shutdown of HVDC and to increase system strength. The dynamic performance of a synchronous machine depends on the characteristics depends of its exciter. In this paper, several exciter types are used to investigate their effect on the dynamic performance of the HVDC system and modifications to standard exciter topologies are suggested to mitigate observed problems.

  • PDF

슬롯 수에 따른 100MW급 권선형 동기발전기 발전특성 및 운전특성 비교 (Operation and Generation Characteristic of 100MW-Class Wound Rotor Synchronous Generator According to Number of Slots)

  • 김창우;박요한;최장영
    • 전기학회논문지
    • /
    • 제68권4호
    • /
    • pp.523-531
    • /
    • 2019
  • This paper deals with a wound-field synchronous machines(WFSM), with an electromagnet on its salient rotor, as an alternative to a permanent magnet in the rotor. We then examine the power performance characteristics, loss characteristics, V-curves and large short-circuit ratios for a large-scale synchronous generator, considering the leading and lagging operations, based on the finite-element method. We predict the performance of a 100MVA-class generator based on the operating range for a constant short-circuit ratio. At the last, We compared with the electromagnetic characteristics of three model according to number of slots.

Sensorless Control of the Synchronous Reluctance Machine

  • Kilthau A.;Pacas J. M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.768-772
    • /
    • 2001
  • The paper deals with the control of the synchronous reluctance machine without position sensor. A method for the computation of the transformation angle out of terminal voltages and currents is presented. The injection of test signals allows operation at zero speed. Fundamental for this control scheme is the exact modelling of the machine, where especially the saturable inductances are of central interest. The accuracy of the angle estimation method over the whole operating range including field-weakening is discussed in detail. The implementation of the angle estimation method in a rotor-oriented control scheme and practical results are demonstrated.

  • PDF