• Title/Summary/Keyword: synchronous generator

Search Result 561, Processing Time 0.028 seconds

A Fast Screening Algorithm for Transient Stability Assessment of Large Power Systems (대규모계통 과도 안정도 평가를 위한 상정사고 고속스크리닝 알고리즘)

  • Yang, Jung-Dae;Lee, Jong-Seock;Lee, Byung-Jun;Kwon, Sae-Hyuk;Lee, Koung-Guk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.69-71
    • /
    • 2000
  • Transient Stability of a power systems is its ability to maintain synchronous operation of machine when subjected to a large disturbance. This paper presents a new methodology for speed-up transient stability evaluation in SIME. SIME is a hybrid direct method including time simulation to enhance flexibility. It is difficult to apply the classical SIME to stable cases. To solve this problem, we propose the improved SIME, applicable to stable cases as well as unstable cases. For more fast screening, a reduced order equivalent generator is used in the first step process

  • PDF

Recursive Design of Nonlinear Disturbance Attenuation Control for STATCOM

  • Liu Feng;Mei Shengwei;Lu Qiang;Goto Masno
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.spc2
    • /
    • pp.262-269
    • /
    • 2005
  • In this paper, a nonlinear robust control approach is applied to design a controller for the Static Synchronous Compensator (STATCOM). A robust control dynamic model of STATCOM in a one-machine, infinite-bus system is established with consideration of the torque disturbance acting on the rotating shaft of the generator set and the disturbance to the output voltage of STATCOM. A novel recursive approach is utilized to construct the energy storage function of the system such that the solution to the disturbance attenuation control problem is acquired, which avoids the difficulty involved in solving the Hamilton-Jacobi-Issacs (HJI) inequality. Sequentially, the nonlinear disturbance attenuation control strategy of STATCOM is obtained. Simulation results demonstrate that STATCOM with the proposed controller can more effectively improve the voltage stability, damp the oscillation, and enhance the transient stability of power systems compared to the conventional PI+PSS controller.

A Fully Differential RC Calibrator for Accurate Cut-off Frequency of a Programmable Channel Selection Filter

  • Nam, Ilku;Choi, Chihoon;Lee, Ockgoo;Moon, Hyunwon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.682-686
    • /
    • 2016
  • A fully differential RC calibrator for accurate cut-off frequency of a programmable channel selection filter is proposed. The proposed RC calibrator consists of an RC timer, clock generator, synchronous counter, digital comparator, and control block. To verify the proposed RC calibrator, a six-order Chebyshev programmable low-pass filter with adjustable 3 dB cut-off frequency, which is controlled by the proposed RC calibrator, was implemented in a $0.18-{\mu}m$ CMOS technology. The channel selection filter with the proposed RC calibrator draws 1.8 mA from a 1.8 V supply voltage and the measured 3 dB cut-off frequencies of the channel selection LPF is controlled accurately by the RC calibrator.

Analysis of Damper Transient in Superconducting Synghronous G (초전도 동기발전기의 댐퍼 과도상태 해석)

  • Chun, Yon-Do;Lee, Hyung-Woo;Lee, Ju
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.125-128
    • /
    • 1999
  • This paper presents the 2-D analysis of damper transient in superconducting of damper transient in superconducting synchronous generator(SCG) using finite element method. Efficient 2-D analysis model which compensates the leakage flux is proposed for the savign of computation time and memory capacity required in 3-D finite element analysis. The characteristics of damper transient in SCG and the prime role of damper also have been evaluated.

  • PDF

A fully digitized Vector Control of PMSM using 80296SA (80296SA를 이용한 영구자석 동기전동기 벡터제어의 완전 디지털화)

  • 안영식;배정용;이홍희
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.5-8
    • /
    • 1998
  • The adaptation to vector control theory is so generalized that it is widely used for implementing the high-performance of AC machine. Nowadays, One-Chip microprocessors or DSP chips are being well-used to implement Vector Control algorithm. DSP Chip have less flexibility for memory decoding and I/O rather than One-Chip microprocessor so that is requires more additional circuit and high cost. And the past One-Chip micro processors have difficult of implementation the complex algorithm because of small memory capacity and low arithmetic performance. Therefore we implemented the vector control algorithm of PMSM(Permanent Magnetic Synchronous Motors) using 80296SA form intel , which have many features as 6M memory space, 500MHz clock frequency, including memory decoding circuit and general I/O, Special I/O(EPA, Interrupt controller, Timer/Count, PWM generator) which is proper controller for the complex algorithm or operation program requiring so much memory capacity, So in this paper we fully digitized the vector control of PMSM included SVPWM Voltage controller using the intel 80296SA

  • PDF

Voltage Impacts of a Variable Speed Wind Turbine on Distribution Networks

  • Kim, Seul-Ki;Kim, Eung-Sang
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.206-213
    • /
    • 2003
  • The main purpose of this paper is to present a simulation model for assessing the impacts of a variable speed wind turbine (VSWT) on the distribution network and perform a simulation analysis of voltage profiles along the wind turbine installed feeder using the presented model. The modeled wind energy conversion system consists of a fixed pitch wind turbine, a synchronous generator, a rectifier and a voltage source inverter (VSI). Detailed study on the voltage impacts of a variable speed wind turbine is conducted in terms of steady state and dynamic behaviors. Various capacities and different modes of variable speed wind turbines are simulated and investigated. Case studies demonstrate how feeder voltages are influenced by capacity and control modes of wind turbines and changes in wind speed under different network conditions. Modeling and simulation analysis is based on PSCAD/EMTDC a software package.

A Fast Screening Algorithm for On-Line Transient Stability Assessment (온라인 과도안정도 판정을 위한 상정사고 고속 스크리닝 알고리즘 개발)

  • Yang, Jung-Dae;Lee, Jong-Seock;Lee, Byung-Jun;Kwon, Sae-Hyuk;Lee, Koung-Guk
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.104-106
    • /
    • 2000
  • Transient Stability of a power systems is its ability to maintain synchronous operation of machine when subjected to a large disturbance. This paper presents a new methodology for speed-up transient stability evaluation in SIME. SIME is a hybrid direct method including time simulation to enhance flexibility. The First features of the proposed method are that generator grouping can be performed even in very stable cases and that the stability of a contingency can be evaluated from a short period of time simulation results. The second features of the proposed method are that using power-angle trajectory and subdividing contingency classification have improved the screening capability.

  • PDF

A Resonant Type Inverter Power Conversion Equipment for Plasma Generator (플라즈마 발생장치용 공진형 인버터 전력변환장치)

  • Kim, Ju-Yong;Suh, Ki-Young;Mun, Sang-Pil;Jung, Jang-Gun;Kim, Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Parallel Inverter Development for 2MW Windpower (2MW 풍력발전기용 병렬형 Inverter 개발)

  • Lee, Hyun-Young;Kang, Sin-Il;Kwon, Oh-Jung;Choi, Hyo-Jin;Kwon, Sei-Jin;Son, Yoon-Gyu;Suh, Jae-Hak;Jang, Sung-Duk;Oh, Jong-Seok;Lee, Byung-Chul;Hwang, Jin-Su;Ryu, Ji-Yoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.336-340
    • /
    • 2007
  • 본 논문에서는 750kW 풍력발전용 인버터를 개발한 결과와 2년 동안의 현장실증을 통하여 얻어진 경험을 바탕으로 2MW 영구자석형 동기발전기(RMSG, Permanent Magnet Synchronous Generator)의 전력변환을 위한 병렬형 인버터의 시뮬레이션과 이를 통한 설계와 제작 및 기본시험 과정을 소개하고자 한다.

  • PDF

Power and loss characteristics of PMSM/G with double-sided Halbach magnetized rotor (양측식 Halbach 자화 회전자를 갖는 영구자석 동기 전동발전기의 출력 및 손실 특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Choi, Sang-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.723-724
    • /
    • 2008
  • The rotational loss is one of the most important problems for the practical applications of PM synchronous motor/generator. This rotational loss is divided as the mechanical loss by windage and bearing and iron loss by hysteresis loop and eddy current in the part of the magnetic field. So, In this paper, a double-sided PMSM/G without the iron loss is designed by analytical method of the magnetic field and estimation of the back-EMF constant represented as the design parameter. This design model consists of the double-sided PM rotor with Halbach magnetized array and coreless 3-phase winding stator. The results show that the double-sided PMSM/G without iron loss can be applicable to the required system without the rotational loss.

  • PDF