• 제목/요약/키워드: synchronous buck regulator

검색결과 9건 처리시간 0.041초

A Driving Scheme Using a Single Control Signal for a ZVT Voltage Driven Synchronous Buck Converter

  • Asghari, Amin;Farzanehfard, Hosein
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.217-225
    • /
    • 2014
  • This paper deals with the optimization of the driving techniques for the ZVT synchronous buck converter proposed in [1]. Two new gate drive circuits are proposed to allow this converter to operate by only one control signal as a 12V voltage regulator module (VRM). Voltage-driven method is applied for the synchronous rectifier. In addition, the control signal drives the main and auxiliary switches by one driving circuit. Both of the circuits are supplied by the input voltage. As a result, no supply voltage is required. This approach decreases both the complexity and cost in converter hardware implementation and is suitable for practical applications. In addition, the proposed SR driving scheme can also be used for many high frequency resonant converters and some high frequency discontinuous current mode PWM circuits. The ZVT synchronous buck converter with new gate drive circuits is analyzed and the presented experimental results confirm the theoretical analysis.

DSP를 이용한 Synchronous Buck Converter의 병렬 제어 (Parallel Control of Synchronous Buck Converter Using DSP)

  • 김정훈;임정규;신휘범;정세교;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.140-142
    • /
    • 2006
  • This paper represents a digital parallel control of a synchronous buck converter using a digital signal processor (DSP). The digital PWM and load sharing controller is implemented in the DSP TMS320F2812 and the experimental results are provided to show the feasibility of the digital synchronous buck regulator.

  • PDF

An Optimized Stacked Driver for Synchronous Buck Converter

  • Lee, Dong-Keon;Lee, Sung-Chul;Jeong, Hang-Geun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권2호
    • /
    • pp.186-192
    • /
    • 2012
  • Half-rail stacked drivers are used to reduce power consumption of the drivers for synchronous buck converters. In this paper, the stacked driver is optimized by matching the average charging and discharging currents used by high-side and low-side drivers. By matching the two currents, the average intermediate bias voltage can remain constant without the aid of the voltage regulator as long as the voltage ripple stays within the window defined by the hysteresis of the regulator. Thus the optimized driver in this paper can minimize the power consumption in the regulator. The current matching requirement yields the value for the intermediate bias voltage, which deviates from the half-rail voltage. Furthermore the required capacitance is also reduced in this design due to decreased charging current, which results in significantly reduced die area. The detailed analysis and design of the stacked driver is verified through simulations done using 5V MOSFET parameters of a typical 0.35-${\mu}m$ CMOS process. The difference in power loss between the conventional half-rail driver and the proposed driver is less than 1%. But the conventional half-rail driver has excess charge stored in the capacitor, which will be dissipated in the regulator unless reused by an external circuit. Due to the reduction in the required capacitance, the estimated saving in chip area is approximately 18.5% compared to the half-rail driver.

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한 연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;이진국
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.32-39
    • /
    • 2003
  • 동기발전기 출력전압은 여자시스템의 계자전류 제어에 의해 일정하게 유지된다. 고주파 PWM 컨버터(전류제어 모드 buck 컨버터) 형태의 여자시스템은 부하변동이 발생하였을 때 동기발전기의 계자전류를 제어하게 된다. 이 논문은 정상상태 및 과도상태에서의 안정화를 개선하기 위하여 여자시스템의 설계 및 실험에 대해 다루었다. 시뮬레이션 및 실험 결과는 제안된 여자시스템이 50[kW] 동기발전기의 DVR에 의해 응답시간이 개선되었음을 보여주었다.

2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템 (A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter)

  • 이상훈;이동희;안진우
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.96-106
    • /
    • 2007
  • 동기발전기의 출력전압은 여자 시스템의 계자 전류 제어에 의해 일정하게 유지된다. 현재 대부분의 발전기 여자기의 여자전류제어를 위해 사용되는 AVR 시스템의 AC/DC 컨버터 부는 출력전압 제어가 가능한 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기와 DC/DC 컨버터를 결합하여 사용하고 있다. AC/DC 전력 변환장치로서 위상제어 컨버터나 출력전압을 제어할 수 없는 다이오드 정류기의 경우, AVR시스템의 전력을 공급하는 모선의 역률저하 및 저차 고조파 발생의 문제점을 야기 시키게 된다. 본 논문에서는 동기발전기의 여자전류 제어를 위해 사용되는 AVR 시스템 설계에 있어 단위역률 동작이 가능한 Boost형 AC/DC 컨버터와 모선의 부하변동에 속응성 있게 동작할 수 있는 전류 제어형 Buck 컨버터를 결합한 2단 3상 PWM AC/DC 컨버터에 대해 연구하였다. 제안된 AC/DC 컨버터를 시뮬레이션 한 결과 Boost 컨버터의 경우 단위 역률 동작 및 출력 DC 전압의 Boost 동작이 원할히 이루어졌으며, Buck 컨버터의 경우 다른 위상제어 컨버터에 비해 응답시간이 개선되었음을 알 수 있었다.

동기발전기 여자시스템용 고주파 PWM 컨버터 설계 (Design of a High Frequency PWM Converter for Synchronous Generator Excitation System)

  • 장수진;류동균;원충연;이진국;배기훈;김수석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.515-518
    • /
    • 2002
  • A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the output voltage constant under normal operating conditions at various levels. The output voltage of Synchronous Generator is regulated constantly by field voltage control in excitation system. High frequency PWM converter (Buck converter) type excitation system for synchronous generator that can sustain prefer output voltage level even at the fault condition happened. The proper operation of the proposed excitation system was verified through the simulations and the experiments.

  • PDF

20kW Hybrid Type 동기 발전기 계자 제어 시스템 (Filed Control System of 20kW Hybrid Type Synchronous Generator)

  • 이화춘;안재영;김세민;유기홍;송성근;최준호;남순열;박성준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.986-987
    • /
    • 2008
  • This paper deals with the novel type DAVR(digital Automatic voltage Regulator) of the field control system for improving the response and efficiency. The proposed Hybrid type Synchronous Generator consists of permanent magnet which can generate the constant voltage with controlless and field winding. Using Buck-type PWM converter, the response can be improved in the proposed system. The proper operation of the proposed excitation system was verified through the design and experiments.

  • PDF