• 제목/요약/키워드: symmetry and asymmetry

검색결과 168건 처리시간 0.031초

노화에 따른 심부 복부근육의 두께 변화와 대칭성 변화 (The Age Related Changes of Thickness and Symmetry of Deep Trunk Muscles)

  • 서동권;이승원
    • 대한물리의학회지
    • /
    • 제8권3호
    • /
    • pp.379-385
    • /
    • 2013
  • PURPOSE: This study is research about deep trunk muscles (DTM) that is important and serve to control the movement of the trunk to provide stability during movement for human. In this study, trying to prove a change of DTM of aging in the ultrasound image. METHODS: We measured via an ultrasound image during rest and contraction of DTM in 42 young and 48 old people, and then we measured the change of thickness and symmetry. RESULTS: Symmetry showed a significant difference only external oblique (EO) in the young(p<.05). In the elderly, it was found that ratio of contraction was greater transverse abdominis than EO. CONCLUSION: I considered it could lead to improvement of activity of daily life by applying intervention for recovery of motor control of TrA for the elderly in clinical practice.

Conservative neural symmetry of the caprine mandible

  • Pares-Casanova, Pere M.
    • 대한수의학회지
    • /
    • 제53권4호
    • /
    • pp.207-210
    • /
    • 2013
  • Fifteen dry dentate and complete mandible samples from the White Rasquera goat breed were studied for symmetry. Thirty-one landmarks were digitally located on the images of the lateral and medial aspects of each hemimandible. Distances between these landmarks allowed the evaluation of the whole hemimandible and also the neural mandible. In the studied samples, the mandible was rather symmetrical, especially in the medial neural part, and in general, there was no side dominance. Only the diastema differed significantly between the sides, and this was related to the rostral part (incisive arch). The incisive region was the least symmetrical region of the caprine mandible, indicating a modular structure more conservative for the neural part. If unsigned asymmetry is interpreted as a measure of developmental stability, then the studied breed presented a marked ability to develop in good fitness despite the harsh environment. The measurements presented here can also be used as a reference for researchers designing experimental studies, especially on mandibular catch-up growth, and as an aid for zooarchaeologists comparing results from dead animals with those from living goat populations.

문양 이미지에 관한 연구[ 1 ] -문양 이미지 포지셔닝 기준 개발을 중심으로- (A Study on Image of Patterns [ 1 ] - With a focus on Development on Image Positioning of Patterns -)

  • 유현정;김민자
    • 복식
    • /
    • 제59권2호
    • /
    • pp.29-41
    • /
    • 2009
  • Perception between real object and recognized subject of human on objective subject is not the same. The reason Is that individual perception of visual design components are transmitted as the image of whole. It is required process of visual perception. Therefore, I developed the vision of seeing image of pattern which is based on Gestalt visual perception theory in clothes. The summary of this study's results is like followings. Extremely antagonistic terms which are specialized by formative characteristics of formative components are clearness and blur of outline/ fixed shape and non-fixed shape/ visuality and tangibility of representation/ simplicity and complexity of structure/ invariability and variability of mobility/ symmetry and asymmetry of arrangements singularity and plurality of group number. The expression of motive shows that clearness, fixed shape, visuality and simplicity pursuit Determination image, and blur, non-fixed shape, tangibility and complexity pursuit Ambiguity image. The arrangements of motive shows that invariability, symmetry and singularity pursuit Order image, and variability asymmetry and plurality pursuit Disorder image. Therefore, the standard of the coordinator of Pattern image positioning is established as Determination and Ambiguity of motive are X-axis, and Order and Disorder of pattern are Y-axis. As the frame of Pattern image positioning, four separated dimensions have made.

Tests for Asymmetry Associated with the Linear Signed Rank Statistics

  • Kim, Soon-Ock
    • 품질경영학회지
    • /
    • 제21권1호
    • /
    • pp.136-143
    • /
    • 1993
  • Tests associated with the linear signed rank statistics are considered for testing the symmetry of a continuous distribution about an unknown median. The results of Monte Carlo study show that the proposed tests are reasonably good in level control and powers.

  • PDF

Discrimination of Spinal Deformity Employing Discriminant Analysis on the $Moir\acute{e}$ Images

  • Kim, Hyoung-Seop;Ishikawa, Seiji;Otsuka, Yoshinori;Shimizu, Hisashi;Nakada, Yasuhiro;Shinomiya, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1990-1993
    • /
    • 2003
  • In this paper, we propose a technique for automatic spinal deformity detection from $moir\acute{e}$ topographic images. Normally the $moir\acute{e}$ stripes show symmetry as a human body is almost symmetric. According to the progress of the deformity of a spine, asymmetry becomes larger. Numerical representation of the degree of asymmetry is therefore useful in evaluating the deformity. First, displacement of local centroids and difference of gray values are evaluated statistically between the left- and the right-hand side regions of the $moir\acute{e}$ images with respect to the extracted middle line. We classify the moire images into two categories i.e., normal and abnormal cases from the features, employing discriminant analysis. An experiment was performed employing 1,200 $moir\acute{e}$ images and 85% of the images were classified correctly.

  • PDF

균일 전단유동 내에 위치한 구 주위의 유동특성 (Characteristics of Flow past a Sphere in Uniform Shear)

  • 김동주;최형석;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1607-1612
    • /
    • 2004
  • Numerical simulations are performed to investigate the characteristics of flow past a sphere in uniform shear. The Reynolds numbers considered are Re=300, 425 and 480 based on the inlet center velocity and sphere diameter. The non-dimensional shear rate K of the inlet uniform shear is varied from 0 to 0.15. At Re=300, the head of the hairpin vortex loop always locates on the high-velocity side in uniform shear, and the flow maintains the planar symmetry. At Re=425 and 480, the irregularity in the location and strength of the hairpin vortex appearing in uniform inlet flow is much reduced in uniform shear, but the flows still keep the asymmetry for most inlet shear rates. However, in the cases of K=0.075 and 0.1 at Re=425, the flows become planar symmetric and their characteristics of the evolution of the hairpin vortex loops are different from those of asymmetric flows. A hysteresis phenomenon switching from the planar symmetry to the asymmetry (or vice versa) depending on the initial condition is also observed at Re=425.

  • PDF

3-Dimensional analysis for class III malocclusion patients with facial asymmetry

  • Kim, Eun-Ja;Ki, Eun-Jung;Cheon, Hae-Myung;Choi, Eun-Joo;Kwon, Kyung-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.168-174
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the correlation between 2-dimensional (2D) cephalometric measurement and 3-dimensional (3D) cone beam computed tomography (CBCT) measurement, and to evaluate the availability of 3D analysis for asymmetry patients. Materials and Methods: A total of Twenty-seven patients were evaluated for facial asymmetry by photograph and cephalometric radiograph, and CBCT. The 14 measurements values were evaluated and those for 2D and 3D were compared. The patients were classified into two groups. Patients in group 1 were evaluated for symmetry in the middle 1/3 of the face and asymmetry in the lower 1/3 of the face, and those in group 2 for asymmetry of both the middle and lower 1/3 of the face. Results: In group 1, significant differences were observed in nine values out of 14 values. Values included three from anteroposterior cephalometric radiograph measurement values (cant and both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). In group 2, comparison between 2D and 3D showed significant difference in 10 factors. Values included four from anteroposterior cephalometric radiograph measurement values (both maxillary height, both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). Conclusion: Information from 2D analysis was inaccurate in several measurements. Therefore, in asymmetry patients, 3D analysis is useful in diagnosis of asymmetry.

안모 비대칭환자의 두부정중선에 대한 비부의 편위 (NASAL DEVIATION IN PATIENTS WITH MANDIBULO-FACIAL ASYMMETRY)

  • 박지화;손성일;장현중;권대근;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.151-159
    • /
    • 2005
  • The purpose of this study was to evaluate the nasal deviation in mandibular prognathism with mandibulo-facial asymmetry. There were 40 patients whose mandibular prognathism with/without facial asymmetry were treated with orthognathic surgery from March 2002 to October 2003. The Group A(n=20) had a mandibulo-facial asymmetry over 6mm menton deviation in cephalogram PA and the Group B(n=20) had a mandibular prognathism. The preoperative frontal photograph, cephalogram PA and three dimensionalcomputed tomography(divided in hard tissuse image and soft tissue image) of two group was evaluated NDA(nasal deviation angle) and MDA(mandibular deviation angle). The NDA was statistical difference between asymmetry Group A and symmetry Group B(p<0.01), and was deviated in affected side of asymmetry. The MDA were also statistical difference between Group A and Group B(p<0.01), however the measurements of MDA between the frontal photograph, 3D-CT and cephalogram PA were similar to each others. The low correlation of NDA between frontal photograph and cephalogram PA in Group A and B demonstrate that we couldn't assess nasal deviation in cephalogram PA. It could be concluded that patients with mandibulo-facial asymmetry have a nasal deviation and clinician must remember this fact when they assess and treat patients.

Tabbed Tissue Expanders Improve Breast Symmetry Scores in Breast Reconstruction

  • Khavanin, Nima;Gust, Madeleine J.;Grant, David W.;Nguyen, Khang T.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • 제41권1호
    • /
    • pp.57-62
    • /
    • 2014
  • Background Achieving symmetry is a key goal in breast reconstruction. Anatomically shaped tabbed expanders are a new tool in the armamentarium of the breast reconstruction surgeon. Suture tabs allow for full control over the expander position and thus inframammary fold position, and, in theory, tabbed expanders mitigate many factors responsible for poor symmetry. The impact of a tabbed expander on breast symmetry, however, has not been formally reported. This study aims to evaluate breast symmetry following expander-implant reconstruction using tabbed and non-tabbed tissue expanders. Methods A chart review was performed of 188 consecutive expander-implant reconstructions that met the inclusion criteria of adequate follow-up data and postoperative photographs. Demographic, oncologic, postoperative complication, and photographic data was obtained for each patient. The photographic data was scored using a 4-point scale assessing breast symmetry by three blinded, independent reviewers. Results Of the 188 patients, 74 underwent reconstruction with tabbed expanders and 114 with non-tabbed expanders. The tabbed cohort had significantly higher symmetry scores than the non-tabbed cohort ($2.82/4{\pm}0.86$ vs. $2.55/4{\pm}0.92$, P=0.034). Conclusions The use of tabbed tissue expanders improves breast symmetry in tissue expander-implant-based breast reconstruction. Fixation of the expander to the chest wall allows for more precise control over its location and counteracts the day-to-day translational forces that may influence the shape and location of the expander pocket, mitigating many factors responsible for breast asymmetry.

시간평균 ESPI를 이용한 대칭.비대칭 적층 복합재료의 진동 특성 비교에 관한 연구 (A Study on the Vibration Characteristics of Symmetry, Asymmetry Laminated Composite Materials by using Time-Average ESPI)

  • 홍경민;유원재;강영준;강신재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.259-260
    • /
    • 2006
  • The ESPI(Electronic Speckle Pattern Interferometry) is a real time, full-field, non-destructive optical measurement technique. In this study, ESPI is proposed for the purpose of vibration analysis for new material, composite material. Composite materials have various complicated characteristics according to the ply materials, ply orientations, ply stacking sequences and boundary conditions. Therefore, it is difficult to analysis composite materials. For efficient use of composite materials in engineering applications the dynamic behavior, that is, natural frequencies, nodal patterns should be informed. If use Time-Average ESPI, can analyze vibration characteristic of composite material by real time easily. This study manufactured laminated composite of symmetry, asymmetry two kinds that is consisted of CFRP(Carbon Fiber Reinforced Plastics) and shape of test piece is rectangular form.

  • PDF