• Title/Summary/Keyword: swirling Flow

Search Result 217, Processing Time 0.023 seconds

Analysis of an internal flow with multi-perforated tube geometry in an integrated Urea-SCR muffler (다공튜브 형상변화에 따른 촉매 삽입형 Urea-SCR 머플러 내부유동 해석)

  • Moon, Namsoo;Lee, Sangkyoo;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.500-509
    • /
    • 2013
  • This study reports a numerical analysis of the internal flow characteristics of the integrated urea-SCR muffler system with the various geometries of the multi-perforated tube which is set up between the muffler inlet and in front of SCR catalysts. The multi-perforated tube is generally used to disperse uniformly the urea-water solution spray and to make better use of the SCR catalyst, resulting in the increased $NO_x$ reduction and decreased ammonia slip. The effects of the multi-perforated tube orifice area ratios on the velocity distributions in front of the SCR catalyst, which is ultimately quantified as the uniformity index, were investigated for the optimal muffler system design. The steady flow model was applied by using a general-purpose commercial software package. The air at the room temperature was used as a working fluid, instead of the exhaust gas and urea-water solution spray mixture. From the analysis results, it was clarified that the multi-perforated tube geometry sensitively affected to the formation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst.

Characteristics of Ammonia Removal from a Synthetic Wastewater in a Jet Loop Reactor with a Two-fluid Venturi-type Swirl Nozzle (이유체 벤츄리형 선회 노즐이 장착된 제트 루프 반응기에서 합성폐수 중의 암모니아 제거특성)

  • Noh, Da-ji;Yun, Chan-Su;Lim, Jun-Heok;Won, Yong-Sun;Lee, Tae-Yoon;Lee, Jea-Keun
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 2017
  • We investigated the performance of a jet loop reactor (JLR) with the two-fluid venturi-type swirl nozzle (TVSN) during experiment for ammonia removal by air stripping from a synthetic wastewater, and compared it with that of a JLR with the two-fluid venturi-type conventional nozzle (TVCN), with the variation of pH, liquid circulation rate ($Q_L$), and air flow rate ($Q_G$). Their performance levels were compared based on the ammonia removal efficiency and overall mass transfer coefficient ($K_La$). Investigated parameters in a JLR were pH (10-12), air flow rate ($Q_G=5-20L\;min^{-1}$), and liquid circulation rate ($Q_L=25-35L\;min^{-1}$). Throughout the experiment, the ammonia removal efficiency and $K_La$ in a JLR with TVSN was higher than in a JLR with TVCN. This may be due to the enhanced turbulent intensity by swirling flow formed in the JLR with TVSN compared to that with TVCN. Further, we obtained higher $K_La$ when pH, $Q_L$ and $Q_G$ were increased. In particular, $K_La$ was increased more efficiently by increasing $Q_G$ than by increasing pH and $Q_L$.

A comparison of the forces on dome and prism for straight and tornadic wind using CFD model

  • Yousef, Majdi A.A.;Selvam, Panneer R.;Prakash, Jai
    • Wind and Structures
    • /
    • v.26 no.6
    • /
    • pp.369-382
    • /
    • 2018
  • Tornadoes are vertical swirling air formed because of the existence of layers of air with contrasting features of temperature, wind flow, moisture, and density. Tornadoes induce completely different wind forces than a straight-line (SL) wind. A suitably designed building for an SL wind may fail when exposed to a tornado-wind of the same wind speed. It is necessary to design buildings that are more resistant to tornadoes. In tornado-damaged areas, dome buildings seem to have less damage. As a dome structure is naturally wind resistant, domes have been used in back yards, as single family homes, as in-law quarters, man caves, game rooms, storm shelters, etc. However, little attention has been paid to the tornadic wind interactions with dome buildings. In this work, the tornado forces on a dome are computed using Computational Fluid Dynamics (CFD) for tornadic and SL wind. Then, the interaction of a tornado with a dome and a prism building are compared and analyzed. This work describes the results of the tornado wind effect on dome and prism buildings. The conclusions drawn from this study are illustrated in visualizations. The tornado force coefficients on a dome building are larger than SL wind forces, about 120% more in x- and y-directions and 280% more in z-direction. The tornado maximum pressure coefficients are also higher than SL wind by 150%. The tornado force coefficients on the prism are larger than the forces on the dome, about 100% more in x- and y-directions, and about 180% more in z-direction. The tornado maximum pressure coefficients on prism also are greater those on dome by 150% more. Hence, a dome building has less tornadic load than a prism because of its aerodynamic shape.

Experimental analysis of vortical structures in a turbulent layer using a dynamic PIV technique (Dynamic PIV를 이용한 난류경계층 내부 와구조 거동의 실험적 분석)

  • Choi, Yong-Seok;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.193-196
    • /
    • 2008
  • The vortical structures in a turbulent boundary layer (TBL) developed over a flat plate have been investigated experimentally. The flow conditions tested in this study were Re$_{\theta}$ = 3700, Re$_{\delta}$ = 11${\times}$105 and the shape factor H = 1.3. Instantaneous velocity fields in the streamwise-wall-normal planes were measured by using a dynamic PIV system. A trip-wire and sandpapers were placed behind the leading edge to promote the turbulent transition. 1000 velocity fields were obtained consecutively with a time interval of 1 millisecond. Streamwise u-velocity components were temporally averaged in the measuring plane. In addition, 2000 velocity fields were obtained randomly and ensemble-averaged to get the fully-developed turbulent characteristics. Profiles of the normalized u-component, turbulent intensities and Reynolds shear stress were evaluated. The structures of spanwise vortices were extracted from the instantaneous velocity fields by determining the swirling strength, ${\lambda}_{ci}$. The wall-normalized locations of vortices were temporally averaged in the measuring plane with respect to their rotational direction. The correlations between the temporally averaged u and the temporally averaged $y^+$ of vortices were evaluated. For the case of positive vortices, the correlation is not significant. However, the negative vortices show a strong negative correlation. The y-location of negative vortices tends to increase, as the averaged u decreases and vice versa. These findings indicate that the number of negative vortices in the outer layer increases during the outward bursting events.

  • PDF

Influence of the Francis Turbine location under vortex rope excitation on the Hydraulic System Stability

  • Alligne, S.;Nicolet, C.;Allenbach, P.;Kawkabani, B.;Simond, J.J.;Avellan, F.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.286-294
    • /
    • 2009
  • Hydroelectric power plants are known for their ability to cover variations of the consumption in electrical power networks. In order to follow this changing demand, hydraulic machines are subject to off-design operation. In that case, the swirling flow leaving the runner of a Francis turbine may act under given conditions as an excitation source for the whole hydraulic system. In high load operating conditions, vortex rope behaves as an internal energy source which leads to the self excitation of the system. The aim of this paper is to identify the influence of the full load excitation source location with respect to the eigenmodes shapes on the system stability. For this, a new eigenanalysis tool, based on eigenvalues and eigenvectors computation of the nonlinear set of differential equations in SIMSEN, has been developed. First the modal analysis method and linearization of the set of the nonlinear differential equations are fully described. Then, nonlinear hydro-acoustic models of hydraulic components based on electrical equivalent schemes are presented and linearized. Finally, a hydro-acoustic SIMSEN model of a simple hydraulic power plant, is used to apply the modal analysis and to show the influence of the turbine location on system stability. Through this case study, it brings out that modeling of the pipe viscoelastic damping is decisive to find out stability limits and unstable eigenfrequencies.

An Experimental Study on the Augmentation of Heat Transfer by Impinging Air Jets with Swirl (충돌선회분류(衝突旋回噴流) 열전달증진(熱傳達增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Ohu, Su-Cheol;Park, Sung-Soo
    • Solar Energy
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 1993
  • This Paper deals with the experimental study of the axisymmetric air jet impinging vertically on the flat heating surface with and without swirl. The purpose of this study is to investigate the characteristics of flow, augmentation of heat transfer rate, turbulent intensity, and the comparison of heat transfer rate, the optimal swirling condition about the swirl and nonswirl axisymmetric air jet. In order to augment the heat transfer on the flat heating surface without introducing any additional power, the technique used in the present work was placement of twisted tape inserted pipe in front of the nozzle exit in order to make a swirl. The effect of swirl degree is investigated in case of S=0., 0.056, 0.111, 0.222 and the velocity of the jet was 14, 20, 26, 32, 38, 44m/s. The distance between the nozle exit and the stagnation point on the impinging plate was the H/D=$1{\sim}14$. In order to analyze of the flow structure which increase heat transfer, the velocity and the turbulent intensity of the axisymmetric jet was measured by a hot wire anemometer according to the swirl number and H/D.

  • PDF

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.