• Title/Summary/Keyword: swelling test

Search Result 386, Processing Time 0.029 seconds

Studies on Evaluation for Long-Term Structural Performance of Pinus densiflora Sieb. et Zucc. (I) -Shear Creep and Mechano-Sorptive Behavior of Drift Pin Jointed Lumber-

  • Hong, Soon-Il;Park, Jun-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.11-18
    • /
    • 2006
  • This study was carried out to evaluate the mechano-sorptive deflection of shear creep of drift pin jointed solid wood. Specimens were the solid wood of Pinus densiflora. The joint was composed with steel plate and drift pin, 85mm in length and 10mm in diameter. The creep tests were conducted under the constant loads in an variable environment. Five different shearing loads were applied parallel to the grain of specimens. The shearing loads applied were 170, 340, 510, 680 and 850 kgf. The stress levels were 10, 20, and 30, 40 and 50% of the bearing strength obtained from the tension-type lateral strength test. The creep tests for specimens were carried out for 10300 hours. A few general conclusions could be drawn from this study: The mechano-sorptive deflection (${\delta}$ ms) is defined as ${\delta}\;ms={\delta}\;t-({\delta}\;c+{\delta}\;sh)-{\delta}\;o$, where ${\delta}$ t is the total deflection, ${\delta}$ c is the pure creep, ${\delta}$ sh is shrinkage-swelling behavior, and ${\delta}$ o is the initial deflection. Changes of relative humidity may cause more severe creep deflection than those of constant humidity, especially during the drying process. The mechano-sorptive behaviors of specimens, except the effects of shrinkage and swelling, gradually increased with increasing time. The deflection is increased in desorption process and recovered in adsorption process. The deflections of drift pin jointed solid wood under different loads showed almost same tendency in all specimens. Although the creep deflection tendencies of each series are very similar, the specimens subjected to a large shearing load exhibit large creep deflections in the desorption process than do those to the small shearing load specimens.

Use of piezoelectric surgery and Er:YAG laser:which one is more effective during impacted third molar surgery?

  • Keyhan, Seied Omid;Fallahi, Hamid Reza;Cheshmi, Behzad;Mokhtari, Sajad;Zandian, Dana;Yousefi, Parisa
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.29.1-29.10
    • /
    • 2019
  • Background: Reduction in postoperative complications is of vital considerations in impacted third molar teeth surgery. The aim of this study was to compare postoperative complications of impacted third molar surgeries for bone removal using laser, piezoelectric equipment, and conventional rotary instruments. Methods: To address the research purpose, the investigator designed the prospective double-blind clinical trial study. The sample size was determined 20 (40 teeth) by sampling formula in any kind of operation. The data of patients were obtained in the different periods in terms of pain, trismus, swelling, ecchymosis, and patient's satisfaction and then analyzed using SPSS 20 software via paired t test and Wilcoxon and McNemar's tests. Results: The pain immediately after surgery and 2 days and 7 days after surgery was higher in the laser group. The swelling immediately after surgery was more in the laser group but not significant. The amount of mouth opening immediately after surgery and 2 days and 7 days after surgery was significantly lower in the laser group than in the piezosurgery group. The total duration of surgery and duration of osteotomy were significantly longer in the laser group. The patient's satisfaction from surgery with piezosurgery was more than that with laser, but this difference was not significant. Conclusion: Due to the rising demand for impacted wisdom tooth surgery, the present study suggests that hard tissue laser surgery and piezosurgery can clear the future of impacted molar surgery, and these approaches are more efficient in reducing postoperative complications compared to the conventional surgeries.

Preparation of Highly Tough Ethylene Vinyl Acetate (EVA) Heterogeneous Cation Exchange Membranes and Their Properties of Desalination

  • Kim, In Sik;Ko, Dae Young;Canlier, Ali;Hwang, Taek Sung
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.361-369
    • /
    • 2018
  • A manufacturing method has been devised to prepare novel heterogeneous cation exchange membranes by mixing ethylene vinyl acetate (EVA) copolymers with a commercial cation exchange resin. Optimum material characteristics, mixture ratios and manufacturing conditions have been worked out for achieving favorable membrane performance. Ion exchange capacity, electrical resistance, water uptake, swelling ratio and tensile strength properties were measured. SEM analysis was used to monitor morphology. Effects of vinyl acetate (VA) content, melt index (MI) and ion exchange resin content on properties of heterogeneous cation exchange membranes have been discussed. An application test was carried out by mounting a selected membrane in a membrane capacitive deionization (MCDI) system to investigate its desalination capability. 0.92 meq/g of ion exchange capacity, $8.7{\Omega}.cm^2$ of electrical resistance, $40kgf/cm^2$ of tensile strength, 19% of swelling ratio, 42% of water uptake, and 56.4% salt removal rate were achieved at best. VA content plays a leading role on the extent of physical properties and performance; however, MI is important for having uniform distribution of resin grains and achieving better ionic conductivity. Overall, manufacturing cost has been suppressed to 5-10% of that of homogeneous ion exchange membranes.

Dimensional Stabilization through Heat Treatment of Thermally Compressed Wood of Korean Pine (잣나무 열압밀화재의 열처리를 통한 치수안정화)

  • Lee, Jeong Min;Lee, Won Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.471-485
    • /
    • 2018
  • Post-heat treatment experiments were carried out for complete dimensional stabilization of thermally compressed wood (Pinus koraiensis). An absorption test was carried out to evaluate the dimensional stability. The specific gravity increased from 0.43 to 0.79 by thermal compression at a compression ratio of 50% thickness. Through the post-heat treatment of compressed wood, the water absorption and thickness swelling decreased with increasing the heat treatment temperature and time. In the case of the thickness recovery rate, when the heat treatment was performed for 24 hours at $120^{\circ}C$, $140^{\circ}C$ and $160^{\circ}C$, the thickness recovery was less than 1%. Therefore, it can be confirmed that the method of dimensional stabilization method of the thermal compression wood can be carried out very effectively through post heat treatment process.

An Experimental Study on the Change of Bulking Coefficient of Soils Mixed with Rock Blades (암버력이 혼재된 토사의 토량환산계수 변화에 관한 실험적 연구)

  • Park, Yeong Mog
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5C
    • /
    • pp.193-198
    • /
    • 2012
  • Field and laboratory tests were performed to investigate the swelling(L value) and shrinkage modulus (C value) of soil and rock mixtures using 2 sites. According to test results, when disturbed soil and rock were mixed with same amount (5:5), the maximum density was achieved and showed 19% and 18% increased at each site comparing with the unit weight of rock only. Since measured L values of mixtures were overestimated about 4 to 11% compare to estimated values based on the conventional method. While C values were underestimated about 13~20% compare to conventional values due to the development of compacting equipments and effective construction management. When rock and soil were mixed in the ratio of 5 to 5, the unit weight of the mixture was higher than that of other mixtures and rock or soil only.

Phenol-Formaldehyde (PF) Resin Bonded Medium Density Fiberboard

  • Park, Byung-Dae;Riedl, Bernard;Park, Sang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.64-71
    • /
    • 1999
  • This study was conducted to manufacture MDF panels bonded with PF resins which provide excellent durability and dimensional stability with panels, and to identify benefits and weaknesses of using PF resins for MDF panels that have been manufactured with urea-formaldehyde (UF) resins for interior applications due to its low dimensional stability under moisture conditions. The results showed that the performance of PF-bonded MDF panels satisfied the performance requirement. A six-cycle aging test also revealed that PF-bonded MDF panels had high durability. Thickness swelling after 24 hours submersion in cold water was less than 2 percent, showing good dimentioanl stability. The identified weaknesses of using PF resins were relatively high resin content and long hot-pressing time. An acceptable resin content appeared to be 8 percent which can increase the production cost of PF-bonded MDF panels. The hot-pressing time (7 minutes) used in this study is relatively long compared to that of UF-bonded MDF panels. This result also indicates that hot-pressing process has to be optimized to control various pressing variables.

  • PDF

Effect of Change in Water Content and NCO Index on the Static Comfort of Polyurethane Seat Foam Pad for Automobiles (물 함량과 NCO Index 변화가 자동차용 폴리우레탄 시트 폼 패드의 정적 안락감에 미치는 영향 고찰)

  • Lee, Byoung Jun;Lee, Sung Hoon;Choi, Kwon Yong;Kim, Sang-bum
    • Applied Chemistry for Engineering
    • /
    • v.28 no.1
    • /
    • pp.57-63
    • /
    • 2017
  • In this study, we identified how the water content change in various NCO index affects the static comfort of polyurethane seat foam pad for automobiles. In order to identify factors that affect the static comfort, a static load test was performed using UTM to plot a hysteresis curve. The hardness of the foam when it was modified by 25, 65%, hysteresis loop area, hysteresis loss (%), and Sag factor were also obtained. By measuring the swelling ratio, it was confirmed that, as the water content increased in a fixed NCO index, the hardness and crosslinking density increased while the restoring force decreased due to the increase of urea bond. Also the Sag factor decreased due to the increase of surface hardness. As the NCO index increased in a fixed water content, the urethane and urea bond reacted more with isocyanate, leading to an increase in hardness and decrease in restoring force.

Transdermal Permeation-enhancing Activities of some Inorganic Anions

  • Ko, Young-Il;Kim, Sung-Su;Han, Suk-Kyu
    • Archives of Pharmacal Research
    • /
    • v.18 no.4
    • /
    • pp.231-236
    • /
    • 1995
  • Effects of sodium salts of various monovalent inorganic anions on transdermal permeation of salicylic acid were investigated. In in-vitro experiment using a Franz-type diffusion cell and excisicylic acid were investigated. In-vitro experiment using a Franze-type diffusion cell and excised mouse skin, the permeation-enhancing activities of the sodium salts of inoraganic anions were rougly proportional to lyotropic Hofmeister serlling abilities of the anions l F/sup -/

  • PDF

IRRADIATION PERFORMANCE OF U-Mo MONOLITHIC FUEL

  • Meyer, M.K.;Gan, J.;Jue, J.F.;Keiser, D.D.;Perez, E.;Robinson, A.;Wachs, D.M.;Woolstenhulme, N.;Hofman, G.L.;Kim, Y.S.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.169-182
    • /
    • 2014
  • High-performance research reactors require fuel that operates at high specific power to high fission density, but at relatively low temperatures. Research reactor fuels are designed for efficient heat rejection, and are composed of assemblies of thin-plates clad in aluminum alloy. The development of low-enriched fuels to replace high-enriched fuels for these reactors requires a substantially increased uranium density in the fuel to offset the decrease in enrichment. Very few fuel phases have been identified that have the required combination of very-high uranium density and stable fuel behavior at high burnup. U-Mo alloys represent the best known tradeoff in these properties. Testing of aluminum matrix U-Mo aluminum matrix dispersion fuel revealed a pattern of breakaway swelling behavior at intermediate burnup, related to the formation of a molybdenum stabilized high aluminum intermetallic phase that forms during irradiation. In the case of monolithic fuel, this issue was addressed by eliminating, as much as possible, the interfacial area between U-Mo and aluminum. Based on scoping irradiation test data, a fuel plate system composed of solid U-10Mo fuel meat, a zirconium diffusion barrier, and Al6061 cladding was selected for development. Developmental testing of this fuel system indicates that it meets core criteria for fuel qualification, including stable and predictable swelling behavior, mechanical integrity to high burnup, and geometric stability. In addition, the fuel exhibits robust behavior during power-cooling mismatch events under irradiation at high power.

The efficacy of dexamethasone injection on postoperative pain in lower third molar surgery

  • Latt, Maung Maung;Kiattavorncharoen, Sirichai;Boonsiriseth, Kiatanant;Pairuchvej, Verasak;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.95-102
    • /
    • 2016
  • Background: Surgery on the lower impacted third molar usually involves trauma in the highly vascularized loose connective tissue area, leading to inflammatory sequelae including postoperative pain, swelling, and general oral dysfunction during the immediate post-operative phase. This study aimed to investigate the effectiveness of preoperative injection of a single dose of 8 mg dexamethasone for postoperative pain control in lower third molar surgery. Methods: A controlled, randomized, split-mouth, prospective study involving lower third molar surgery was performed in 31 patients. The randomized sampling group was preoperatively injected, after local anesthesia, with a single dose of dexamethasone (8 mg in 2 ml) through the pterygomandibular space; 2 ml of normal saline (with no dexamethasone) was injected as a placebo. Results: The pain VAS score was significantly different on the day of the operation compared to the first post-operative day (P = 0.00 and 0.01, respectively), but it was not significantly different on the third and seventh postoperative day between the control and study groups. There was a significant reduction in swelling on the second postoperative day, and a difference between the second postoperative day and baseline value in the study group (P < 0.05). Trismus was highly significantly different on the second postoperative day and between baseline and second postoperative day between the groups (P = 0.04 and 0.02, respectively). Descriptive statistics and independent-samples t- test were used to assess the significance of differences. Conclusions: Injection of 8 mg dexamethasone into the pterygomandibular space effectively reduced the postoperative pain and other postoperative sequalae.