• 제목/요약/키워드: sustained voltage

Search Result 48, Processing Time 0.02 seconds

Effect of Some Design Factors in the Front Panel on the Characteristics of a Plasma Display

  • Kim, Beong-Ju;Moon, Chelo-Hee
    • Journal of Information Display
    • /
    • v.9 no.3
    • /
    • pp.28-32
    • /
    • 2008
  • Low sustained voltage $(V_s)$ and high luminous efficiency (lumen/Watts) are required for the enhanced performance of an AC PDP. Both are not realized in the same condition, however, because luminous efficiency decreases when the sustained voltage is lowered in most cases. In this study, the three design factors in the front panel of a PDP, i.e., the thickness and position of the bus electrode and the thickness of the dielectric layer, were chosen to investigate how they affect the sustained voltage and the luminous efficiency, and to find a way to optimize them. Two values were given to each of the three design factors, and experiments were done via full factorial design, i.e., with a total of eight conditions, using a 3-in.diagonal test panel. The changes in the sustained voltage and the luminous characteristics were explained in connection with the discharge characteristics of the PDP cells.

Evaluation of Reliability Worth Considering Sustained Interruptions and Voltage Sags (영구정전과 순간전압강하를 고려한 신뢰도 비용 평가)

  • Lee, Hee-Tae;Moon, Jong-Fil;Seol, Kyu-Hwan;Yun, Sang-Yun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.13-20
    • /
    • 2008
  • Power quality problems such as momentary interruptions and voltage sags do not great influence on loads at past. However, the interests in power quality problems increase as the use of sensitive loads with microprocessor like computers increases recently. Accordingly, power system reliability research focusing to sustained interruption and momentary interruption partially needs more accurate evaluation methods including momentary and instantaneous problems. That is, many sensitive loads being tripped by voltage sags result in interruption costs. In this paper, new reliability worth evaluation method is presented considering voltage sags. We calculated the magnitude of voltage sags using fault studies and the duration of voltage sags using the trip time of protective relays for each fault. Moreover, we includes the customer interruption cost resulted from sensitive load trip by voltage sags. Through case studies, we evaluate the effects of voltage sags for permanent faults.

Two Types of Voltage-activated Calcium Currents in Goldfish Horizontal Cells

  • Paik, Sun-Sook;Bai, Sun-Ho;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.5
    • /
    • pp.269-273
    • /
    • 2005
  • In horizontal cells (HCs) that were freshly dissociated from goldfish retina, two types of voltagedependent calcium currents ($I_{Ca}$) were recorded using a patch-clamping configuration: a transient type current and a sustained type current. The cell was held at -40 mV, and the prepulse step of -90 mV was applied before command pulse between -65 and +55 mV. The transient $Ca^{2+}$ current was activated by depolarization to around -50 mV from a prepulse voltage of -90 mV lasting at least 400 ms and reached a maximal value near -25 mV. On the other hand, the sustained $Ca^{2+}$ current was induced by pre-inactivation for less than 10 ms duration. Its activation started near -10 mV and peaked at +20 mV. $Co^{2+}$ (2 mM) suppressed both of these two components, but nifedipine ($20{\mu}M$), L-type $Ca^{2+}$ channel antagonist, blocked only the sustained current. Based on the activation voltage and the pharmacolog$I_{Ca}$l specificity, the sustained current appears to be similar to L-type $I_{Ca}$ and the transient type to T-type $I_{Ca}$. This study is the first to confirm that transient type $I_{Ca}$ together with the sustained one is present in HCs dissociated from goldfish retina.

Reliability Evaluation of Power Distribution Systems Considering a Momentary Voltage Quality (순시전압 품질을 고려한 배전계통에서의 신뢰도 평가)

  • Yun, Sang-Yun;Kim, Jae-Chul;Bae, Joo-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.202-205
    • /
    • 2002
  • This paper presents the reliability evaluation methods considering the momentary voltage quality in power distribution systems. The voltage qualify phenomena deal with this paper are sustained and momentary interruptions and voltage sags. Conventional evaluation indices and methods are summarized for the sustained interruptions, and the assessment methodologies of momentary interruptions and voltage sags are proposed. The evaluation methods are divided into the analytical method and Time Sequential Monte Carlo simulation. The proposed methods are tested using the modified RBTS (Roy Billinton Test System) form and historical reliability data of KEPCO system.

  • PDF

Sustained $K^+$ Outward Currents are Sensitive to Intracellular Heteropodatoxin2 in CA1 Neurons of Organotypic Cultured Hippocampi of Rats

  • Jung, Sung-Cherl;Eun, Su-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.5
    • /
    • pp.343-348
    • /
    • 2012
  • Blocking or regulating $K^+$ channels is important for investigating neuronal functions in mammalian brains, because voltage-dependent $K^+$ channels (Kv channels) play roles to regulate membrane excitabilities for synaptic and somatic processings in neurons. Although a number of toxins and chemicals are useful to change gating properties of Kv channels, specific effects of each toxin on a particular Kv subunit have not been sufficiently demonstrated in neurons yet. In this study, we tested electro-physiologically if heteropodatoxin2 ($HpTX_2$), known as one of Kv4-specific toxins, might be effective on various $K^+$ outward currents in CA1 neurons of organotypic hippocampal slices of rats. Using a nucleated-patch technique and a pre-pulse protocol in voltage-clamp mode, total $K^+$ outward currents recorded in the soma of CA1 neurons were separated into two components, transient and sustained currents. The extracellular application of $HpTX_2$ weakly but significantly reduced transient currents. However, when $HpTX_2$ was added to internal solution, the significant reduction of amplitudes were observed in sustained currents but not in transient currents. This indicates the non-specificity of $HpTX_2$ effects on Kv4 family. Compared with the effect of cytosolic 4-AP to block transient currents, it is possible that cytosolic $HpTX_2$ is pharmacologically specific to sustained currents in CA1 neurons. These results suggest that distinctive actions of $HpTX_2$ inside and outside of neurons are very efficient to selectively reduce specific $K^+$ outward currents.

Sustained Oscillation of an Inverter-Fed Induction Motor Drive System and its Stabilization

  • Li Hongmei;Hikihara Takashi
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.80-84
    • /
    • 2006
  • The sustained oscillation of rotor speed is often experienced in PWM inverter induction motor (IM) drive systems. In this paper the oscillation is investigated from the point of view of Hopf bifurcation theory. The sufficient and necessary conditions for existence of limit cycle are introduced to determine the bifurcation set in the stator voltage versus stator frequency plane. According to the conditions it is clarified that the bifurcation set inherently exists in the instable operation of IM. Moreover, it is numerically shown that the V/f curve can be adjusted to stabilize the sustained oscillation of rotor speed.

A Digital Self-Sustained Phase Shift Modulation Control Strategy for Full-Bridge LLC Resonant Converters

  • Zheng, Kai;Zhou, Dongfang;Li, Jianbing;Li, Li;Zhao, Yujing
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.915-924
    • /
    • 2016
  • A digital self-sustained phase shift modulation (DSSPSM) strategy that allows for good soft switching and dynamic response performance in the presence of step variations is presented in this paper. The working principle, soft switching characteristics, and voltage gain formulae of a LLC converter with DSSPSM have been provided separately. Furthermore, the method for realizing DSSPSM is proposed. Specifically, some key components of the proposed DSSPSM are carefully investigated, including a parameter variation analysis, the start-up process, and the zero-crossing capture of the resonant current. The simulation and experiment results verify the feasibility of the proposed control method. It is observed that the zero voltage switching of the switches and the zero current switching of the rectifier diodes can be easily realized in presence of step load variations.

An Analysis of Delayed Voltage Recovery Phenomenon according to the Characteristics of Motor Load in Korean Power System (모터부하 특성에 따른 국내 전력계통의 전압 지연 회복 현상 분석)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.178-182
    • /
    • 2016
  • FIDVR(Fault Induced Delayed Voltage Recovery) is a phenomenon that recovery of the system voltage level delays after the fault. Cause of FIDVR phenomenon is motor load characteristic about voltage and reactive power. In low voltage condition, the motor go to stall state that consume large amount of reactive power. As a result, the voltage recovery problem is that of repeated occurrences of sustained low voltage following faults on the system. In this paper, analysis the characteristics of the motor load. And using the korean power system actual data, perform a case studies to voltage delay recovery phenomenon alleviation method. Change of each parameters by analyzing the effect on system and selecting an influence parameter. In addition, dynamic characteristic analysis of the resulting difference in the proportion by the motor load in power systems, considering the effect on the voltage stability.

Four Voltage-Gated Potassium Currents in Trigeminal Root Ganglion Neurons

  • Choi, Seung Ho;Youn, Chang;Park, Ji-Il;Jeong, Soon-Yeon;Oh, Won-Man;Jung, Ji-Yeon;Kim, Won-Jae
    • International Journal of Oral Biology
    • /
    • v.38 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • Various voltage-gated $K^+$ currents were recently described in dorsal root ganglion (DRG) neurons. However, the characterization and diversity of voltage-gated $K^+$ currents have not been well studied in trigeminal root ganglion (TRG) neurons, which are similar to the DRG neurons in terms of physiological roles and anatomy. This study was aimed to investigate the characteristics and diversity of voltage-gated $K^+$ currents in acutely isolated TRG neurons of rat using whole cell patch clamp techniques. The first type (type I) had a rapid, transient outward current ($I_A$) with the largest current size having a slow inactivation rate and a sustained delayed rectifier outward current ($I_K$) that was small in size having a fast inactivation rate. The $I_A$ currents of this type were mostly blocked by TEA and 4-AP, K channel blockers whereas the $I_K$ current was inhibited by TEA but not by 4-AP. The second type had a large $I_A$ current with a slow inactivation rate and a medium size-sustained delayed $I_K$ current with a slow inactivation rate. In this second type (type II), the sensitivities of the $I_A$ or $I_K$ current by TEA and 4-AP were similar to those of the type I. The third type (type III) had a medium sized $I_A$ current with a fast inactivation rate and a large sustained $I_K$ current with the slow inactivation rate. In type III current, TEA decreased both $I_A$ and $I_K$ but 4-AP only blocked $I_A$ current. The fourth type (type IV) had a smallest $I_A$ with a fast inactivation rate and a large $I_K$ current with a slow inactivation rate. TEA or 4-AP similarly decreased the $I_A$ but the $I_K$ was only blocked by 4-AP. These findings suggest that at least four different voltage-gated $K^+$ currents in biophysical and pharmacological properties exist in the TRG neurons of rats.

Measurement of a Threshold Initiation Carrier Density for a Reduction in Gas Breakdown Voltage

  • Park, Hyunho;Kim, Youngmin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2421-2424
    • /
    • 2018
  • A direct measurement of an initiation carrier injection for a low voltage discharge is presented. A self-sustained pulsed discharge is utilized to characterize electrical responses of a glow discharge for varying amounts of injected initiation carriers. It is clearly demonstrated that the initiation carrier injection affects the ignition time and the breakdown voltage of the primary discharge. An abrupt reduction in the breakdown voltage for a $300{\mu}m$ gap pin-plate discharge is observed when a threshold carrier density of $3{\times}10^{11}cm^{-3}$ is injected and the breakdown voltage continues to decrease to 250 V with increasing the initiation carrier injection beyond the threshold density.