• Title/Summary/Keyword: sustain discharge

Search Result 161, Processing Time 0.029 seconds

Electron Temperature, Plasma Density and Luminous Efficiency in accordance with Discharge Time in coplanar AC PDPs

  • Jeong, S.H.;Moon, M.W.;Oh, P.Y.;Jeong, J.M.;Ko, B.D.;Park, W.B.;Lee, J.H.;Lim, J.E.;Lee, H.J.;Han, Y.G.;Son, C.G.;Lee, S.B.;Yoo, N.L.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1203-1206
    • /
    • 2005
  • Electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDP's) have been experimentally investigated in accordance with discharge time by a micro-probe in this experiment. The resolution of a step mortor to move in micro-Langmuir probe is 10um.[1-3] The used gas in this experiment is He-Ne-Xe (4%) mixure gas. And sustain voltage is 320V which is above of firing voltage for degradation. The electron temperature and plasma density can be obtained from current-voltage (I-V) characteristics of micro Langmuir probe, in which negative to positive bias voltage was applied to the probe. And Efficiency is calculated by formula related discharge power and light emission. Those experiments operated as various discharge time ($0{\sim}72$ Hours). As a result of this experiment, Electron Temperature was increased from 2eV to 5eV after discharge running time of 20 hours and saturates beyond 20 hours. The plasma density is inversely proportional to the square root of electron temperature. So the plasma density was decreased from $1.8{\times}10^{12}cm^{-3}$ to $8{\times}10^{11}cm^{-3}$ at above discharge running time. And the Efficiency was reduced to 70% at 60hours of discharge running time.

  • PDF

Effect of Various ${\prod}$Type Metal Electrode in the AC PDP (AC PDP에서 다양한 형태의 ${\prod}$형 금속방전유지 전극의 효과)

  • Yoo, Su-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.586-590
    • /
    • 2009
  • Recently, an AC Plasma Display Panels(PDP) with the metal sustain electrodes have been reported in order to reduce the manufacturing cost of the AC PDP. However, the luminance and efficacy of the AC PDP with metal electrodes are worse than those of the AC PDP with ITO electrodes. In this paper, various ${\prod}$type metal electrodes are suggested, in order to improve the electro-optical characteristics of the AC PDP with metal electrodes. Among the suggested electrode types, luminance of Hump electrode structure is higher by $40\;cd/m^2$ and discharge current of Asymmetry electrode structure is lower by 5% than those of Pi electrode structure, respectively. Moreover, $T_1$ of Hump electrode structure is reduced to 10% as compared with Pi electrode structure in address period for ADS driving scheme. In all aspects, the characteristics of Hump and Asymmetry electrode structure show best performance.

The Measurement and Analysis of Three-Dimensional Light Emitted from Plasma Disp1ay Panel by Optica1 Method (광학적인 방법에 의한 플라즈마 디스플레이 패널의 3차원 광 방출 측정과 분석)

  • Choe, Hun-Yeong;Lee, Seok-Hyeon;Lee, Seung-Geol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.31-38
    • /
    • 2002
  • We measured a 3-dimensional images of the light emitted from plasma display panel(PDP) by using newly proposed scanned point detecting system. In the panel without phosphor, as we scan from the rear glass to the front glass, the detected light intensity increases and the light intensity detected in the inside edge of the ITO electrodes shows the stronger intensity than others. The light intensity detected between the barrier ribs shows the largest value of brightness. Also, as the sustain voltage increases, the detected light intensity increases. In the panel with phosphor, the intensity of light detected at barrier rib shows the stronger light intensity than rear plate. Therefore, the phosphor of barrier rib is very important. From these results the 3-dimensional measurement is necessary to understand exactly the discharge phenomenon in the PDP cell.

Wall Voltage Characteristics Simulated Using an Equivalent Circuit Model for AC POPs

  • Kim, Joon-Yub;Lim, Jong-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.317-320
    • /
    • 2003
  • As a convenient means for the characterization of the wall voltage and wall charge of AC PDPs during the sustain period, an equivalent circuit model for AC PDPs is presented. The equivalent circuit model for AC PDPs consists of capacitors and thyristors. The equivalent circuit model is based on the physical structure of the AC PDP and the I-V characteristic of the discharge space. This equivalent circuit model can be easily implemented in the standard simulators such as SPICE and can easily simulate the variation of the current, charge and voltage involved in AC PDPs as the supply voltage varies.

  • PDF

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.329-332
    • /
    • 2003
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse was applied to the address electrode during a sustain-period, was examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. The luminance, luminous efficiency and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cell was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

  • PDF

The characteristics of wall charge on the dependence of aging time in an AC Plasma Display Panel

  • Kim, Bhum-Joon;Cho, Hyung-Joon;Lee, Seung-Hun;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.710-713
    • /
    • 2003
  • The wall charge is major factor to determine the discharge characteristics. The minimum sustain voltage related to the wall charge decay were investigated as a function of aging time in AC plasma display panel. For the long time scale, the wall charge decay time is dependent on the aging time. The inverse time scale of the wall charge decay has the maximum value at around 3 hours aging time and then fell down.

  • PDF

Effect of ramp-type erase pulse waveform on the high Temperature driving characteristics of ac PDP

  • Choi, Joon-Young;Kim, Dong-Hyun;Heo, Jeong-Eun;Ryu, Sung-Nam;Ryu, Jae-Hwa;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.57-60
    • /
    • 2002
  • This paper deals with the effect of ramp-type erase pulse waveform on the high temperature driving characteristics of ac PDP driven by ramp up-down reset waveform. The experimental results show that the discharge characteristics in the reset period are significantly affected by the erase pulse waveform and ambient temperature. The firing voltage is increased with ambient temperature. This can cause misfirings during the sustain period and should be avoided. As one of possible solutions, we propose the optimization of erasing pulse shape.

  • PDF

New Address Waveform for Improvement of the Priming Effect and the Contrast Ratio (AC-PDP에서 프라이밍 효과를 이용한 대조비 향상에 관한 연구)

  • Kwon, Shi-Ok;Kim, Ji-Sun;Joung, Bong-Kyu;Hwang, Ho-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1120-1124
    • /
    • 2004
  • Recently, Plasma Display Panel(PDP) has been in the spotlight as one of the next generation flat-panel-display device. However, it has several drawbacks like the low contrast ratio and the low luminance. In this study, a new address waveform is suggested to improve the priming effect and contrast ratio at the address period in the Address Display period Separated(ADS) method. We modified waveform, instead of a conventional waveform, to an address period, for operating on the Plasma Display Panels, which used the conventional gas [He-Ne-Xe〕. When the ramp pulse is added to the address period at the sustain electrode, it is improved on the priming effect and contrast ratio.

A Study on the Image Sticking Phenomenon in AC PDP (AC PDP의 Image Sticking 현상에 관한 연구)

  • Lim, Sung-Hyun;Shim, Kyoung-Ryul;Kim, Dong-Hyun;Lee, Ho-Joon;Park, Chung-Hoo;Kim, Gyu-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1640-1643
    • /
    • 2002
  • Image sticking, the phenomenon that the previously displayed pattern still remains after the image is changed into different image, is one of the most serious problem in realizing high picture quality. In this paper, we tried characterizing this undesirable feature in terms of the luminance and the intial firing voltage at ramp up time in reset period. It was found that the cell located at the boundary of previous image pattern show low firing voltage and high background luminance. And the results show that the degree of the image sticking is severely affected by discharge duration and the length of the sustain period.

  • PDF

Design of Cost-Effective Driving Waveform Based on Vt Close Curve Analysis in AC Plasma Display Panel

  • Cho, Byung-Gwon;Tae, Heung-Sik;Ito, Kazuhiro;Song, Jun-Weon;Lee, Myoung-Kyu;Kim, Sang-Chul;Jung, Nam-Sung;Lee, Kwang-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.251-254
    • /
    • 2005
  • A new driving waveform was proposed to reduce the cost in PDP-TV based on Vt close curve by eliminating the common (X) board under the conventional 42-inch panel structure. Due to the serious misfiring problem during a sustain-period when applying the new driving waveform, the wall voltage was measured and analyzed after the reset-period using Vt close curve. As a result of adopting the proposed driving waveform designed using Vt close curve analysis, the cost of PDP module could reduce compared with the conventional PDP module without any misfiring discharge.

  • PDF