• Title/Summary/Keyword: suspended particulate

Search Result 266, Processing Time 0.027 seconds

Pretreatment Process for Performance Improvement of SIES at Kori Unit 2 in Korea

  • Lee, Sang-Jin;Yang, Ho-Yeon;Shin, Sang-Woon;Song, Myung-Jae
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.12-27
    • /
    • 2004
  • Pretreatment process consisted of submerged hollow-fiber microfiltration(HMF) membrane and spiral-wound nanofiltration(SNF) membrane has been developed by NETEC, KHNP for the purpose of improving the impurities of liquid radioactive waste before entering Selective Ion Exchange System(SIES). The lab-scale combined system was installed at Kori NPP #2 nuclear power plant and demonstration tests using actual liquid radioactive waste were carried out to verify the performance of the combined system. The submerged HMF membrane was adopted for removal of suspended solid in liquid radioactive waste and the SNF membrane was used for removal of particulate radioisotope such as, Ag-l10m and oily waste because ion exchange resin can not remove particulate radioisotopes. The liquid waste in Waste Holdup Tank (WHT) was processed with HMF and SNF membrane, and SIES. The initial SS concentration and total activity of actual waste were 38,000ppb and $1.534{\times}10_{-3}{\mu}Ci/cc$, respectively. The SS concentration and total activity of permeate were 30ppb and lower than LLD(Lower Limit of Detection), respectively.

  • PDF

Organic Matter in the Sediments of Youngsan River Estuary : Distribution and Sources (영산강 하구역 퇴적물의 유기물 분포와 기원)

  • Woo, Jun-Sik;Choi, Heeseon;Lee, Hyo-Jin;Kim, Tae-Ha
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1375-1383
    • /
    • 2014
  • Total organic carbon(TOC), Total nitrogen(TN), and carbon and nitrogen stable isotopes were measured in the sediment and suspended parties in fresh lake water and saline estuarine water to determine the sources of Particulate organic matter(POM) in the sediments of the Youngsan river estuary. POM in the freshwater discharge water was mostly phytoplankton origin with little trace of terrestrial plants. POM from phytoplankton blooms formed in estuarine water in response to the nutrient enriched freshwater discharges was the most important sources of POM in the sediment near the dike, comprising more than 40% of the total organic matter. POM from freshwater phytoplankton and oceanic phytoplankton were also important sources of the sediment POM, and their contributions varied with the distances from the dike. Contribution of freshwater phytoplankton to sediment POM decreased from the dike to the outside of the estuary.

The Concentration And Distribution Of Iron In The Water Of Lake Eui-Am (의암땜 하류수역의 철분량과 그 분포)

  • Choe, Sang;Kwak, Hi-Sang
    • 한국해양학회지
    • /
    • v.5 no.2
    • /
    • pp.52-58
    • /
    • 1970
  • Concentrations of the total, dissolved and particulate iron in waters of Lake Eui-Am have been determined spectrophotometrically on August 14, 1970. O-phenanthroline was the reagent used. Iron contents of the lake water were varied by the station and depth. Analyses showed variations in the total iron ranging from 238 to 2,643 ${\mu}$g/l (mean value 1,028${\mu}$g/l); the dissolved iron varied from 34.5 to 137.7 ${\mu}$g/l (mean value 83.0${\mu}$g/l), and the particulate iron varied from 179 to 2,544 ${\mu}$g/l (mean value 943 ${\mu}$g/l). Three forms of iron tend to increase with depth. This is believed that the suspended matter plays an important role in regulating of iron contents in summer season.

  • PDF

Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room (음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화)

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

Afzelin suppresses proinflammatory responses in particulate matter-exposed human keratinocytes

  • Ju Hee Kim;Minjeong Kim;Jae Min Kim;Mi‑Kyung Lee;Seong Jun Seo;Kui Young Park
    • International Journal of Molecular Medicine
    • /
    • v.43 no.6
    • /
    • pp.2516-2522
    • /
    • 2019
  • Particulate matter (PM), a widespread airborne contaminant, is a complex mixture of solid and liquid particles suspended in the air. Recent studies have demonstrated that PM induces oxidative stress and inflammatory reactions, and may cause certain skin diseases. Afzelin is a flavonoid isolated from Thesium chinense Turcz, which has anti-inflammatory, anticancer and antibacterial properties. Therefore, the present study aimed to investigate if afzelin affected inflammatory responses in human keratinocytes exposed to PM. HaCaT cells were treated with PM (25 ㎍/cm2) in the presence or absence of afzelin (200 µM). Here, standard reference material 1649b was used as PM. Cell viability was assessed using the water-soluble tetrazolium salt-1 assay. The generation of reactive oxygen species (ROS) was measured using the dichloro-dihydro-​fluorescein diacetate assay. Gene and protein expression were investigated using reverse transcription-quantitative polymerase chain reaction and western blot analysis, respectively. Levels of secreted inflammatory cytokines were measured using ELISA. The results suggested that afzelin inhibited PM-induced proinflammatory cytokine mRNA expression and protein secretion in HaCaT cells. In addition, afzelin suppressed PM-induced intracellular ROS generation, and p38 mitogen-activated protein kinase and transcription factor activator protein-1 component c-Fos and c-Jun activation. The results indicated that afzelin exerts anti-inflammatory and antioxidant effects in PM-exposed HaCaT. Afzelin may have potential for preventing PM-induced inflammatory skin diseases.

Diurnal and Nocturnal Behaviour of Airborne Cryptomeria japonica Pollen Grains and the Allergenic Species in Urban Atmosphere of Saitama, Japan

  • Wang, Qingyue;Nakamura, Shinichi;Lu, Senlin;Nakajima, Daisuke;Suzuki, Miho;Sekiguchi, Kazuhiko;Miwa, Makoto
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.65-71
    • /
    • 2013
  • Japanese cedar (Cryptomeria japonica) pollinosis is the most popular pollinosis in Japan. It has been reported that Cryptomeria japonica pollen allergenic species are suspended as fine particles in the urban atmosphere. These allergenic fine particles are responsible for inducing asthma by breaking into the lower respiratory tract. It has also been found that pollinosis symptoms on the sufferers appear mainly at night-time by the results from epidemiological studies. However, the exact reason for these phenomena is not yet clarified. In this study, the diurnal and nocturnal behaviours of Cryptomeria japonica pollen grains and their allergenic species in the urban area of Saitama city of Kanto Plain were investigated. Airborne pollen grains and allergenic Cry j 1 concentrations in total suspended particulate matter (TSP) were investigated at two sampling sites, a heavy traffic road (roadside site) and at the balcony of the $10^{th}$ floor of the Building of Research and Project of Saitama University (general urban site). The latter sampling site where located about 300 m away from the roadside site was used as a general urban site unaffected by automobile traffic. The airborne pollen counts were measured with a real-time pollen monitor. Cry j 1 particles were collected with two high volume air samplers, and these concentrations were measured by surface plasmon resonance method with a Biacore J system. The diurnal variation of the airborne pollen counts was similar to the trends of temperature and wind speed during the day-time; whereas its tendency with wind speed trend was not observed during the night-time. Airborne pollen counts were lower with northern wind than with southern wind because the pollen comes from the mountainous areas, and the mountains in the south are closer, about half the distance to the northern mountains. It is suggested that the peaks of airborne pollen counts during night-time in the sampling site occurred by transport of pollen grains released during day-time in the mountainous forest areas, located c.a. 100 km away from the sampling site. On the roadside site the allergenic Cry j 1 concentrations were higher than at the general urban site, nevertheless pollen grains counts were lower. These results suggested that worsening of pollinosis symptoms during night-time in urban area was caused by transport of pollen grains during day-time in the mountainous forest areas. Moreover, pollen allergenic species become different morphology from pollen grain at roadside site, and the subsequent pollen grains re-suspension by automobile traffic.

Water Column Structure and Dispersal Pattern of Suspended Particulate Matter (SPM) in a floating ice-dominated fjord, Marian Cove, Antarctica during Austral Summer (유빙이 점유한 남극 마리안 소만의 하계기간 수층 구조와 부유물질 분산)

  • Yoo, Kyu-Cheul;Yoon, Hoo-Il;Kang, Cheon-Yun;Kim, Boo-Keun;Oh, Jae-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.295-304
    • /
    • 2000
  • Vertical measurement of CTDT at about 30 min intervals and spatial surface temperature, salinity, and concentration of suspended particulate matters were conducted to elucidate the character of water column and the dispersal pattern in a floating ice-dominated fjord, Marian Cove, West Antarctica. Marian Cove showed two distinct water layers in terms of turbidity; 1) cold, fresh, and turbid surface plume in the upper 2 m,2) warm, saline, and relatively clean Maxwell Bay inflow between 15-45 m in water depth. Thermal melting of Maxwell Bay inflow and tidewater glacier/floating ices developed the surface mixed layer and the activity of floating ices cause Maxwell Bay inflow to be unstable. Due to the unstable water column, the development of Maxwell Bay inflow and subsequent surface plume are not influenced by tidal frequency. Coastal current generated by strong northwesterly wind may extend warm, saline, and turbid surface plume into the central part of the cove along the northern coast via the western coast of Weaver Peninsula. Terrigenous sediments of meltwaters from the glaciated ice cliffs near the corner of tidewater glacier and some coasts enter into the cove and their dispersion depends upon the hydrographic regimes (tide, wind, wave etc.). At the period of spring tide, the strong wind stress with the northwesterly wind direction reserve suspended sediment-fed surface plume and so allow the possibility of deposition of terrigenous sediments within the basin of cove.

  • PDF

Size Distribution of Suspended Particulate Materials in the Southern East Sea of Korea (한국 동해 남부 해역의 부유물질의 입도분포에 관한 연구)

  • Park, Yong Ahn;Kim, Kyung-Ryul;Choi, Jin Yong;Park, Soo Chul
    • 한국해양학회지
    • /
    • v.23 no.2
    • /
    • pp.76-88
    • /
    • 1988
  • Size distribution of suspended particulate materials (SPM) in the coastal waters of eastern Korea was studied using a laser particle size analyzer. Mean particle size (MPS) ranges from 3.69 to 8.40 ${\mu}m$ in surface waters, from 3.38 to 6.43 ${\mu}m$ in mid-depth waters, and from 3.88 to 8.30 ${\mu}m$ in near-bottom waters. For smaller MPS, the size distribution is unimodal, whereas it becomes polymodal as the MPS increases. Particle concentrations increased with the increases in MPS, suggesting that processes of adding larger particles in the waters such as resuspension of bottom sediments are more important in controlling MPS in the area than processes of removing smaller particles such as flocculation of fine particles. Observations of higher MPS near the coast in mid-depth waters, and at the continental slope in near-bottom waters appear to support the above idea. For surface waters with high MPS, mean particle density was noticably low, indicating the importance of biological activities in the formation of suspended particles.

  • PDF

Characteristic Analysis and Effect of Particulate Material in Drinking Water Distribution Networks (상수도관망에서 입자성 물질의 특성분석 및 영향조사)

  • Kim, Do-Hwan;Lee, Doo-Jin;Hwang, Jin-Su;Choi, Doo-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.312-320
    • /
    • 2013
  • Particulates in drinking water distribution system (DWDS) are mostly influenced by internal corrosion of metal pipes and sediment in pipelines due to the solution of this effect is limited. The particle size, component and properties of compounds for particulates in distributed water are different and the difference of these characteristics will be occurred by the kind of facilities, pipe condition, external factors and supply system etc. In this study, conducting the investigation of water quality in DWDS researches with particulates in the water. Monitoring sites were each water supply reservoir and the end of water supply area in DWDS. To collect particulate material at each sampling site, $47{\phi}$ glass microfiber filter type GF/C was performed using a filtration. Substances that the effect of the turbidity in the water according to particulate suspended solids and inorganic materials is due to the increasing particulates in the end of DWDS were increased. The result of compounds analysis by using X-ray diffraction (XRD) were Goethite (${\alpha}$-FeOOH), Magnetite ($Fe_3O_4$) in the end of DWDS and Quartz ($SiO_2$), Yeelimite ($Ca_4Al_6O_{12}SO_4$) at the effluent of waterworks and reservoirs. There were differences the compounds and sediments in the releasing or remaining water distribution facilities.