• Title/Summary/Keyword: surgical tool

Search Result 269, Processing Time 0.033 seconds

Radiographic and CT Diagnosis Of Otitis Media In a Dog (개에서 컴퓨터 단층촬영상을 통한 중이염의 진단)

  • 이기창;서은정;권정국;송경진;윤정희;최민철
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.184-186
    • /
    • 2004
  • A castrated male, 6 year-old Shih-Tzu, weighing 4.6 kg with a discharge from the external ear canal and a mal-odor was referred to Verterinary Medical Teaching Hospital, Seoul National University. Radiographic findings were narrowing and focal loss of an air density in the left ear canal and bilateral thickening of the osseous bullae. For more detail examination, computed tomography was used. In computed tomographic findings, bilateral thickening of the bulla wall and increased opacity of the bulla space were observed. Thus this dog was diagnosed as bilateral otitis media. Then surgical correction, total ear canal ablation, was performed successfully and the patient showed a good prognosis thereafter. It is considered that computed tomography might serve as an useful imaging tool for otitis media and that it supplies information not obtained with a conventional radiography.

Force-Feedback Control of an Electrorheological Haptic Device in MIS Virtual Environment (ER 유체를 이용한 햅틱 마스터와 가상 MIS 환경의 연동제어)

  • Kang, Pil-Soon;Han, Young-Min;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.422-427
    • /
    • 2006
  • This paper presents force-feedback control performance of a haptic device in virtual environment of minimally invasive surgery(MIS). As a first step, based on an electrorheological(ER) fluid and spherical geometry, a new type of master device is developed and integrated with a virtual environment of MIS such as a surgical tool and human organ. The virtual object is then mathematically formulated by adopting the shape retaining chain linked(S-Chain) model. After evaluating reflection force, computational time, and compatibility with real time control, the virtual environment of MIS is formulated by interactivity with the ER haptic device in real space. Tracking control performances for virtual force trajectory are presented in time domain, and theirtrackingerrorsareevaluated.

  • PDF

A study of isometric position of the knee during anterior cruciate ligament reconstruction (전십자 인대 재건시 등장위치에 관한 연구)

  • 박정홍;손권;김광훈;문병영;서정탁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.158-161
    • /
    • 2004
  • The isometric position of the anterior cruciate ligament was calculated during flexion-extension. Flexion-extension motion data of the knee joint were obtained by Fastrak, a three-dimensional motion measurement system. A subject was seated on a flat table and the tibia sensor position was measured with the femur fixed at the table. A three-dimensional knee model was constructed using a graphic tool to simulate the knee motion. Three surgical positions of the femoral tunnel were selected and the distances between the determined tibial tunnel and each femoral tunnel were calculated. The maximum elongation position was found to be in the ten thirty direction of clock.

  • PDF

Force-feedback Control of an Electrorheological Haptic Device in MIS Virtual Environment (전기유변 유체를 이용한 햅틱 마스터와 가상의 최소침습수술 환경과의 연동제어)

  • Kang, Pil-Soon;Han, Young-Min;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.12 s.117
    • /
    • pp.1286-1293
    • /
    • 2006
  • This paper presents force-feedback control performance of a haptic device in virtual environment of minimally invasive surgery(MIS). As a first step, based on an electrorheological (ER) fluid and spherical geometry, a new type of master device is developed and integrated with a virtual environment of MIS such as a surgical tool and human organ. The virtual object is then mathematically formulated by adopting the shape retaining chain linked(S-chain) model. After evaluating reflection force, computational time, and compatibility with real time control, the virtual environment of MIS is formulated by interactivity with the ER haptic device in real space. Tracking control performances for virtual force trajectory are presented in time domain.

Photobiomodulation and implants: implications for dentistry

  • Tang, Elieza;Arany, Praveen
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.6
    • /
    • pp.262-268
    • /
    • 2013
  • The use of dental implants has become a mainstay of rehabilitative and restorative dentistry. With an impressive clinical success rate, there remain a few minor clinical issues with the use of implants such as peri-implant mucositis and peri-implantitis. The use of laser technology with implants has a fascinating breadth of applications, beginning from their precision manufacturing to clinical uses for surgical site preparation, reducing pain and inflammation, and promoting osseointegration and tissue regeneration. This latter aspect is the focus of this review, which outlines various studies of implants and laser therapy in animal models. The use of low level light therapy or photobiomodulation has demonstrated its efficacy in these studies. Besides more research studies to understand its molecular mechanisms, significant efforts are needed to standardize the clinical dosing and delivery protocols for laser therapy to ensure the maximal efficacy and safety of this potent clinical tool for photobiomodulation.

Extraction of Canine Cataract Object for Developing Handy Pre-diagnostic Tool with Fuzzy Stretching and ART2 Learning

  • Kim, Kwang Baek
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.1
    • /
    • pp.21-26
    • /
    • 2016
  • Canine cataract is developed with aging and can cause the blindness or surgical treatment if not treated timely. The first observation must be made by pet owners but they do not have proper equipment and knowledge to see the abnormalities. In this paper, we propose an intelligent image processing method to extract canine cataract suspicious object from non-professional equipment such as ordinary digital camera and cellular phone photographs so that even casual owners of pet dog can make a pre-diagnosis of such a surgery-needed disease as soon as possible. The experiment shows that the proposed method is successful in most cases except the dog has similar colored hair to the color of cataract.

Intraneural Venous Malformations of the Median Nerve

  • Porto, Sara Alicia Gonzalez;Rodriguez, Alba Gonzalez;Miguez, Jose Midon
    • Archives of Plastic Surgery
    • /
    • v.43 no.4
    • /
    • pp.371-373
    • /
    • 2016
  • Venous malformations arising from the peripheral nerve are a rare type of vascular malformation. We present the first case of an intraneural venous malformation of the median nerve to be reported in a child and review the previous two cases of median nerve compression due to a venous malformation that have been reported. These cases presented with painless masses in the volar aspect of the wrist or with symptoms suggestive of carpal tunnel syndrome. Clinical suspicion should lead to the use of Doppler ultrasonography as the first-line diagnostic tool. Magnetic resonance imaging and histopathology can confirm the diagnosis, as phleboliths are pathognomonic of venous malformations. Surgical treatment appears to be the only modality capable of successfully controlling the growth of an intraneural malformation. Sclerotherapy and radiotherapy have never been used to treat this type of malformation.

A Clinical Study of Thoracic Injuries: 190 Cases (흉부손상의 임상적 고찰: 190예)

  • 이지원
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.123-126
    • /
    • 1981
  • 190 cases of the thoracic injuries experienced at the department of chest surgery, Chungnam National University Hospital, for 5 years from Jan. 1976 till Dec 1980, were analysed. The results are as follows; 1. The incidence rate of male to female was 5.1:1. The common age groups were 3rd, 4th and 5th decades, and the most common age group in the penetrating injury was 3rd decade. 2. The most common mode of the nonpenetrating injuries was a traffic accident [63.0%], and the most commonly used tool in the penetrating injuries is a knife [66.7%]. 3. The most common nonpenetrating injury was rib fracture [73.9%], and the common fracture sites were 5th, 6th, 7th and 8th ribs [especially, 7th rib]. The incidence rate of flail chest was 15% of the cases of the rib fractures. 4. The common associated injuries of the nonpenetrating were long bone fracture [18.3%], brain contusion [15.9%], and clavicle fracture etc.. 5. The common method of surgical treatment were closed thoracostomy [46.7%], thoracentesis, and open thoracotomy [7.4%] etc.. 6. The overall mortality was 2.8%. [Nonpenetrating; 0.8%, Penetrating; 6.3%]

  • PDF

Clinical Application of Electromyography for Monitoring Procedure and Result of Orthodontic Treatment ; A of Three Cases (성장기 부정교합환자의 근신경계 부조화를 해소한 증례: 교정치료 과정과 결과를 모니터링하기 위한 근전도검사(EMG)의 임상적 응용)

  • Cha, Bong-Kuen;Lee, Nam-Ki;Choi, Dong-Soon;Kim, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.89-100
    • /
    • 2006
  • Traditionally, goals of orthodontic treatment fall into four categories: good tooth alignment, improvement of skeletal profile and good soft tissue, and rehabilitation of the normal function. Electromyography (EMG) has proven as useful tool in evaluating masticatory function among the maxillomandibular relationship and could be useful in accompanying orthodontic treatment objectives. But in pursuit of clinical application, it is necceassry to systemize clinical guideline for diagnosis by EMG records in evaluating the effects of orthodontic, orthopedic, or surgical treatment. This study present 3 orthodontic cases, which treatment results, ie neuromuscular balances of masticatory muscle, could be moitered by EMG procedure.

Clinical Application of SPECT and PET in CerebroVascular Disease (뇌혈관질환에서 SPECT와 PET의 임상적 응용)

  • Ra, Young-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • Single photon emission computed tomography(SPECT) and positron emission tomography(PET) are modern imaging techniques that allow for both qualitative and quantitative assessment of hemodynamic changes in cerebrovascular diseases. SPECT has been becoming an indispensable method to investigate regional cerebral blood flow because equipment and isotope are easily available in most general hospitals. Acetazolamide stress SPECT has also been proved to be useful to evaluate the cerebrovascular reserve of occlusive cerebrovascular diseases and to select surgical candidate. PET has gained wide spread clinical use in the evaluation of the hemodynamic and metabolic consequences of extracranial or intracranial arterial obstructive disease despite its complexity and limited availability. PET has been established as an invaluable tool in the pathophysilogy investigation of acute ischemic stroke. The potentials, limitations, and clinical applications of SPECT and PET in various cerebrovascular diseases will be discussed in this article with reviews of literatures.