마스터/슬레이브 복합형 고관절 전치환 수술로봇의 제어 (Control of a Master/Slave Combined Surgical Robot for Total Hip Arthroplasty)

  • 허관회;권동수;김상연;이정주;윤용산
    • 제어로봇시스템학회논문지
    • /
    • 제8권9호
    • /
    • pp.788-794
    • /
    • 2002
  • To improve surgical result of total hip arthroplasty (THA), there has been some approaches using a robotic milling system, which can make a precise cavity in the femur. Usually, to carve a femur, the surgical robot is controlled by a pre-programmed tool-path regardless of a surgeon's experience and Judgment. This paper presents a control method of a surgical robot for THA, which can be used as an advanced surgical tool. With a master/slave combined surgical robot, surgeon can directly control the motion and velocity of a surgical robot. The master/slave-combined robot is controlled to display a specific admittance for a surgeon's force to the surgical robot velocity. To prevent the over-carving of a femur, virtual hard wall is displayed on the surgical boundary. To evaluate the proposed control method of the master/slave-combined surgical robot, 2-DOF master/slave-combined manipulator is used in experiment.

Master/Slave 복합형 고관절 전치환 수술 로봇의 설계와 제어 (Design and Control of a Master/Slave Combined Surgical Robot for Total Hip Replacement Surgery)

  • 권동수;허관희;정종하;박영배;이정주;원중희;윤용산
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.540-540
    • /
    • 2000
  • This paper explores design and control methods of a surgical robot for total hip replacement surgery which can be easily maneuvered by a surgeon Like an advanced surgical tool. The 3-DOF in-parallel surgical robot is fixed directly onto patient's femur by the bone clamp during surgery. With the master/slave combined surgical robot, the surgeon can directly control the motion of the surgical robot with surgeon's experience and judgment during operation. For the easiness of operation, the master/slave combined robot is controlled using admittance control paradigm. And for the precise operation, the robot motion is restricted at the surgical boundary using virtual hard wall display.

  • PDF

Computer Integrated Surgical Robot System for Spinal Fusion

  • Kim Sungmin;Chung Goo Bong;Oh Se Min;Yi Byung-Ju;Kim Whee Kuk;Park Jong Il;Kim Young Soo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.265-270
    • /
    • 2005
  • A new Computer Integrated Surgical Robot system is composed of a surgical robot, a surgical planning system, and an optical tracking system. The system plays roles of an assisting surgeon and taking the place of surgeons for inserting a pedicle screw in spinal fusion. Compared to pure surgical navigation systems as well as conventional methods for spinal fusion, it is able to achieve better accuracy through compensating for the portending movement of the surgical target area. Furthermore, the robot can position and guide needles, drills, and other surgical instruments or conducts drilling/screwing directly. Preoperatively, the desired entry point, orientation, and depth of surgical tools for pedicle screw insertion are determined by the surgical planning system based on CT/MR images. Intra-operatively, position information on surgical instruments and targeted surgical areas is obtained from the navigation system. Two exemplary experiments employing the developed image-guided surgical robot system are conducted.

개방형 로봇 플랫폼 기반 미세수술로봇의 안전성 및 성능평가에 관한 연구 (A Study on Safety and Performance Evaluation of Micro - surgical Robots Based on Open Robot Platform)

  • 박준현;호예지;이덕희;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.206-214
    • /
    • 2019
  • Surgical methods and associated precision systems have been developed, but surgical procedures that require precise location and fine manipulation of the lesion remain a limitation. The combination of precision robot manipulation technology and 3D medical image navigation technology overcomes the limitations of minimally invasive surgery (MIS) and enables a more stable and successful operation. Surgical robots are surgical robots such as da Vince, and surgical robots using industrial robotic arms. There are various developments and researches of medical robots. In recent medical robot development, a new type of surgical robot based on an industrial robot arm capable of easily replacing the end effector according to the user's needs is being actively developed at home and abroad. Therefore, in this study, we developed safety and performance evaluation guideline for micro - surgical robots based on open robot platform using general purpose robot arm to help quality control of the medical device.

손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스 (Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture)

  • 장익규
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권3호
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Single-port robot-assisted prosthetic breast reconstruction with the da Vinci SP Surgical System: first clinical report

  • Joo, Oh Young;Song, Seung Yong;Park, Hyung Seok;Roh, Tai Suk
    • Archives of Plastic Surgery
    • /
    • 제48권2호
    • /
    • pp.194-198
    • /
    • 2021
  • Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed in an attempt to seek smaller and indistinct incisions. Robotic surgery system has been evolving under the concept of minimal invasive technique which is a recent trend in surgery. One of the latest version is the da Vinci SP Surgical System (Intuitive Surgical). In this report, we will share our experiences. Two patients underwent robot-assisted nipple-sparing mastectomy, each followed by immediate robot-assisted expander insertion and prepectoral direct-to-implant breast reconstruction, respectively. There was no open conversion or major postoperative complication. One patient experienced mild infection, which was resolved by intravenous antibiotic treatment. Simple docking process, multi-joint instruments, and thirdarm functionality are among the new surgical system's advantages. The present cases suggest that robot-assisted nipple-sparing mastectomy with immediate reconstruction using the da Vinci SP Surgical System is feasible and safe. The promising features and potential application of da Vinci SP in breast reconstruction need further study.

의료로봇의 현재와 미래: 수술로봇을 중심으로 (The Present and Future of Medical Robots: Focused on Surgical Robots)

  • 송미옥;조용진
    • 디지털융복합연구
    • /
    • 제19권4호
    • /
    • pp.349-353
    • /
    • 2021
  • 본 연구는 4차혁명 시대에 수술로봇에 대한 선행연구를 바탕으로 수술로봇의 현황을 분석하고, 향후 수술로봇이 나아가야 할 방향에 대해 전망하고자 시도된 고찰 연구이다. 수술로봇은 '다빈치' 로봇 출시 이후 본격적인 발전이 이루어졌으며, 현재까지는 수술로봇이 의료진의 의도를 반영한 마스터-슬레이브(Master-Slave) 방식이나 의료진의 수술을 보조하는 역할을 수행하고 있다. 최근 수술로봇에 인공지능과 빅데이터를 접목하고, 수술 전용 플랫폼이 아닌 범용성 플랫폼 상용화를 위해 기술이 개발되고 있다. 더욱이, 진단 영상자료를 바탕으로 한 3D 영상 자료 생성, vision probe를 통한 실시간 영상 제공, 영상자료를 하나의 시스템 내로 통합하여 수술로봇 자동화를 위한 기술이 개발되고 있다. 수술로봇의 발전을 위해서는 임상가와 공학자와의 긴밀한 협력, 수술로봇 기술 대한 안전관리, 수술로봇 활용을 위한 제도적 뒷받침이 필요할 것이다.

힘/토크 센서를 이용한 수술보조로봇의 원격중심운동 직접교시 알고리즘 연구 (Study on Direct Teaching Algorithm for Remote Center Motion of Surgical Assistant Robot using Force/Torque Sensor)

  • 김민효;진상록
    • 로봇학회논문지
    • /
    • 제15권4호
    • /
    • pp.309-315
    • /
    • 2020
  • This study shows a control strategy that acquires both precision and manipulation sensitivity of remote center motion with manual traction for a surgical assistant robot. Remote center motion is an essential function of a laparoscopic surgical robot. The robot has to keep the position of the insertion port in a three-dimensional space, and general laparoscopic surgery needs 4-DoF (degree-of-freedom) motions such as pan, tilt, spin, and forward/backward. The proposed robot consists of a 6-axis collaborative robot and a 2-DoF end-effector. A 6-axis collaborative robot performs the cone-shaped trajectory with pan and tilt motion of an end-effector maintaining the position of remote center. An end-effector deals with the remaining 2-DoF movement. The most intuitive way a surgeon manipulates a robot is through direct teaching. Since the accuracy of maintaining the remote center position is important, direct teaching is implemented based on position control in this study. A force/torque sensor which is attached to between robot and end-effector estimates the surgeon's intention and generates the command of motion. The predefined remote center position and the pan and tilt angles generated from direct teaching are input as a command for position control. The command generation algorithm determines the direct teaching sensitivity. Required torque for direct teaching and accuracy of remote center motion are analyzed by experiments of panning and tilting motion.

An Image-Guided Robotic Surgery System for Spinal Fusion

  • Chung Goo Bong;Kim Sungmin;Lee Soo Gang;Yi Byung-Ju;Kim Wheekuk;Oh Se Min;Kim Young Soo;So Byung Rok;Park Jong Il;Oh Seong Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.30-41
    • /
    • 2006
  • The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods for spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Some experiments employing the developed robotic surgery system are conducted. The experimental results confirm that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to respiration.